Schmersal SLC445-ER-0490-30-01 (Order No: 103005407) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +50 °C; Amb...
Glorient offers competitive supply of Schmersal SLC445-ER-0490-30-01, Order No: 103005407. Competitive pricing, fast quotation.
Schmersal SLC445-ER-0490-30-01 - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal SLC445-ER-0490-30-01 is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 1,080 g |
| Net weight | 1,080 g |
| Ambient temperature | -25 ... +50 °C |
| Ambient temperature, maximum | +50 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | CLC/TS 61496-2, EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661436210 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Reaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Rated operating current: 250 | Current consumption: 0 … 2 mA (LOW) | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | PIN 11: Not used | PIN 4: COD2 Coding 2 | Beam coding available : Yes | Radiation emission level to EN 12198-1: Category 0 | Designation, Contactor controls EDM (Feedback circuits): D_IN | EPLAN: Yes | Integral system diagnostics, status: Yes | PIN 5: D_OUT Operating Mode | Actuation time for manual start: 50 … 1500 | Switching voltage: 0 … 2 V (LOW) | Height of the Sensor (Transmitter): 571 | PIN 2: 0 VDC power supply | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | ACE reference article number: 11930064 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | Override: Yes | TOL_VOLT_OPERAT_DC_MIN: -10 | Terminal connector, Recipient: Connector plug M12, 12-pole | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Designation, Control inputs: S1, S2, MSG 1 and MSG 2 | CADENAS: Yes | Blanking function: Yes | PIN 8: Input Release S2 | Restart interlock (manual reset): Yes | Designation, Power supply: ML | Range, protection field, maximum: 10 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Classification ZVEI CB24I, Source: C3 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Contactor control integrated: Yes | Designation, Safety outputs: OSSD 1 and OSSD 2 | Clock control possible : Yes | PIN 6: OSSD 2 Safety output 2 | Safety Integrity Level (SIL), suitable for applications in: 3 | LED status: OSSD ON, OSSD OFF, restart, signal reception, blanking, information | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Height of the protection field: 490 | Rated operating voltage: 24 | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Height of the Sensor (Receiver): 581 | Muting function: Yes | PIN 3: 0 VDC power supply | Note (Software Version): as of 2024 Version 1.0 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Reduced resolution : Yes | Reaction time of the external devices, maximum: 500 | Detection ability for test bodies at v = 1.6 m/s: 30 | Number of beams: 24 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |
In addition to SLC445-ER-0490-30-01, Glorient also supplies:
Schmersal safety switchgear is widely used in machine guarding and process safety applications, including CNC machining centres, robotic cell fencing, packaging and bottling lines, material handling equipment, press and forming machinery, and automated assembly stations. Choosing the correct interlock or position switch with the right contact rating and coding level is essential to meeting your machine's PL or SIL requirements.
Yes. All Schmersal products we supply are 100% genuine and new in original factory packing, sourced from authorised supply channels with full factory warranty.
Schmersal safety switches use positive-break (Zwangsöffnung) contacts designed to EN 60947-5-1, which guarantee contact separation even if the actuator is forced out or the spring fails. This is the core requirement for safety circuits rated up to PL e according to EN ISO 13849-1.
Send us the part number through the quote form and our team will respond within 24 hours with pricing, stock availability and estimated delivery time.
| Gross weight | 1,080 g |
| Net weight | 1,080 g |
| Ambient temperature | -25 ... +50 °C |
| Ambient temperature, maximum | +50 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | CLC/TS 61496-2, EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661436210 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Reaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Rated operating current: 250 | Current consumption: 0 … 2 mA (LOW) | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | PIN 11: Not used | PIN 4: COD2 Coding 2 | Beam coding available : Yes | Radiation emission level to EN 12198-1: Category 0 | Designation, Contactor controls EDM (Feedback circuits): D_IN | EPLAN: Yes | Integral system diagnostics, status: Yes | PIN 5: D_OUT Operating Mode | Actuation time for manual start: 50 … 1500 | Switching voltage: 0 … 2 V (LOW) | Height of the Sensor (Transmitter): 571 | PIN 2: 0 VDC power supply | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | ACE reference article number: 11930064 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | Override: Yes | TOL_VOLT_OPERAT_DC_MIN: -10 | Terminal connector, Recipient: Connector plug M12, 12-pole | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Designation, Control inputs: S1, S2, MSG 1 and MSG 2 | CADENAS: Yes | Blanking function: Yes | PIN 8: Input Release S2 | Restart interlock (manual reset): Yes | Designation, Power supply: ML | Range, protection field, maximum: 10 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Classification ZVEI CB24I, Source: C3 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Contactor control integrated: Yes | Designation, Safety outputs: OSSD 1 and OSSD 2 | Clock control possible : Yes | PIN 6: OSSD 2 Safety output 2 | Safety Integrity Level (SIL), suitable for applications in: 3 | LED status: OSSD ON, OSSD OFF, restart, signal reception, blanking, information | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Height of the protection field: 490 | Rated operating voltage: 24 | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Height of the Sensor (Receiver): 581 | Muting function: Yes | PIN 3: 0 VDC power supply | Note (Software Version): as of 2024 Version 1.0 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Reduced resolution : Yes | Reaction time of the external devices, maximum: 500 | Detection ability for test bodies at v = 1.6 m/s: 30 | Number of beams: 24 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |