Schmersal AZM190-02/01RK-230VAC (Order No: 131182119) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient temperature: ...
Glorient offers competitive supply of Schmersal AZM190-02/01RK-230VAC, Order No: 131182119. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to AZM190-02/01RK-230VAC, Glorient also supplies:
| Gross weight | 480 g |
| Net weight | 480 g |
| Ambient temperature | -25 ... +55 °C |
| Ambient temperature, maximum | +55 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | BG-GS-ET-19, EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus, CCC |
| Housing material | Glass-fibre, reinforced thermoplastic |
| EAN (European Article Number) | 8905236102271 |
| Mission time | 20 |
| Termination | Screw terminals |
| Mechanical lifetime, minimum | 1,000,000 |
| Length of sensor | 41 mm |
| Switching element | Magnet: 2 NC contacts / Actuator: 1 NC contact |
| Switching principle | slow action, positive break NC contact |
| Width of sensor | 52 mm |
| Thermal test current | 4 A |
| Cable section, maximum | 1.5 mm² |
| Height of sensor | 178 mm |
| Material of the contacts, electrical | Silver |
| Utilisation category DC-13 | 24 VDC / 4 A |
| Max. fuse rating | 4 A gG D-fuse to DIN EN 60269-1 |
| Utilisation category AC-15 | 230 VAC / 4 A |
| Maximum switching frequency | 1,200 Hz |
| Cable section, minimum | 0.5 mm² |
| Number of safety contacts | 1 / 2 / 3 / 4 |
| Required rated short-circuit current | 1,000 A |
| Actuating speed, maximum | 0.3 m/s |
| Note | All indications including the conductor ferrules. |
| Number of auxiliary contacts | 1 / 2 |
| Scope of delivery | Actuator must be ordered separately. |
| Mounting | Screws |
| Protection class | II |
| Other Parameters | Voltage, Utilisation category DC-13: 24 | Voltage, Utilisation category AC-15: 230 | Test pulse interval, minimum: 50 | Power to unlock: Yes | Tightening torque of electrical connection, maximum: 0.6 | Test pulse duration, maximum: 5 | Note (Relative humidity): non-condensing | Coding level according to EN ISO 14119: Low | Traceparts, product ID: 33-22052019-077278 | Electrical power consumption, maximum: 8.5 | Cable entry: 2 x M20 x 1,5 | Performance Level, up to: e | Working principle: electromechanical | Latching force: 20 N | Protection class (Operating resource): 2 | Tightening torque of electrical connection, minimum: 0.5 | Magnet switch-on time: 100 | Rated control voltage: 230 | Current, Utilisation category DC-13: 4 | Note (Manual release): front | Positive break force, minimum: 20 | Current, Utilisation category AC-15: 4 | Number of cable glands: 2 | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Manual release: Yes | Category: 3 | Note (applications): removable guard | Replacement article number: 101182119 | ACE reference article number: 193782 | Number of actuating directions: 4 | Type of the fixing screws: 2x M5 |