Glorient offers competitive supply of PULS TP960.484, Order No: TP960.484. Competitive pricing, fast quotation.
PULS TP960.484 - industrial power supply / AC/DC Power Supplies.
| DC Output | 48 - 56 Vdc | 24 - 20.6 A | 960 W |
| Input | AC 380 - 500 V (-15 %/+10 %) |
| Dimensions (WxHxD) | 79 x 124 x 136 mm |
| Weight | 1100 g |
| Features | 3AC 48 V, 960 W Compact width: Only 79 mm Efficiency 97.1 % at 48 V, 20 A Power losses at no load: 3.6 W Dynamic BonusPower management: Max. 1920 W for up to 15 s and 1152 W continuous (up to +45 °C) Enhanced HiccupPLUS protects connected systems and power supply from overload Remote control of output voltage AC-OK and DC-OK relay contacts Active current share bus for constant output voltage in parallel use Output voltage adjustable in six steps LED bar for visual monitoring the output power |
| Commercial Info | Article number: TP960.484 | Product status: Lead time on request | Warranty period (months): 36 | Country of origin: Czech Republic | Packaging unit: 1 PU pc | Weight per piece (excl. packaging): 1100 g | Customs tariff number: 85044083 |
| CRA relevant product | No |
| Article number | TP960.484 |
| Customs tariff number | 85044083 |
| Warranty period (months) | 36 |
| Mounting method | DIN rail |
| Product status | Lead time on request |
| Packaging unit | 1 PU pc |
| Country of origin | Czech Republic |
| Weight per unit (excl. packaging) | 1100 g |
| Weight per piece (excl. packaging) | 1100 g |
| Connection method | Spring clamps |
| Output current | 20.6 A at 56 V |
| Nominal voltage | 48 Vdc |
| Adjustment range | 48 - 56 V |
| Output current range | 24 - 20.6 A |
| AC Input voltage | AC 380 - 500 V (-15 %/+10 %) |
| MTBF SN 29500 @ 40 °C (h) | 342 000 h |
| Power losses, typ. | 27 W |
| Output power | 960 W |
| Efficiency, typ. | 97.2 % | 97.1 % |
| Ripple and noise voltage max. | 50 mVpp |
| Derating | 12.8 W/°C for +45 to +60 °C |
| Operating temp. range | -40 °C to 70 °C |
| Input inrush current limitation | active |
| Power factor | 0.93 |
| External input fuse recommendation | B-6 A / C-6 A |
| Power reserves | 200 % BonusPower |
| DC-OK signal | yes |
UB10.241 | FPS300.245-055-109 | UF20.241 | ML15.121 | CP10.241-S1 | CP10.481 | CP20.248-IOL | CS10.241 | ML50.109 | PIC240.241D | PIM90.245-L1 | QS20.361 | ML90.200 | QT40.481 | XT40.721 | FPT500.245-034-105 | CD5.242 | CD10.482 | YR40.482 | UZO12.072 | BUS-BAR1-L102 | PAS395 | SLZ12 | AP157.121 | AP336.112 | SL40.301 | CP5.241 | ZM11.SIDE | PISA-M-4ADJ | UBC10.241-N1
| DC Output | 48 - 56 Vdc | 24 - 20.6 A | 960 W |
| Input | AC 380 - 500 V (-15 %/+10 %) |
| Dimensions (WxHxD) | 79 x 124 x 136 mm |
| Weight | 1100 g |
| Features | 3AC 48 V, 960 W Compact width: Only 79 mm Efficiency 97.1 % at 48 V, 20 A Power losses at no load: 3.6 W Dynamic BonusPower management: Max. 1920 W for up to 15 s and 1152 W continuous (up to +45 °C) Enhanced HiccupPLUS protects connected systems and power supply from overload Remote control of output voltage AC-OK and DC-OK relay contacts Active current share bus for constant output voltage in parallel use Output voltage adjustable in six steps LED bar for visual monitoring the output power |
| Commercial Info | Article number: TP960.484 | Product status: Lead time on request | Warranty period (months): 36 | Country of origin: Czech Republic | Packaging unit: 1 PU pc | Weight per piece (excl. packaging): 1100 g | Customs tariff number: 85044083 |
| CRA relevant product | No |
| Article number | TP960.484 |
| Customs tariff number | 85044083 |
| Warranty period (months) | 36 |
| Mounting method | DIN rail |
| Product status | Lead time on request |
| Packaging unit | 1 PU pc |
| Country of origin | Czech Republic |
| Weight per unit (excl. packaging) | 1100 g |
| Weight per piece (excl. packaging) | 1100 g |
| Connection method | Spring clamps |
| Output current | 20.6 A at 56 V |
| Nominal voltage | 48 Vdc |
| Adjustment range | 48 - 56 V |
| Output current range | 24 - 20.6 A |
| AC Input voltage | AC 380 - 500 V (-15 %/+10 %) |
| MTBF SN 29500 @ 40 °C (h) | 342 000 h |
| Power losses, typ. | 27 W |
| Output power | 960 W |
| Efficiency, typ. | 97.2 % | 97.1 % |
| Ripple and noise voltage max. | 50 mVpp |
| Derating | 12.8 W/°C for +45 to +60 °C |
| Operating temp. range | -40 °C to 70 °C |
| Input inrush current limitation | active |
| Power factor | 0.93 |
| External input fuse recommendation | B-6 A / C-6 A |
| Power reserves | 200 % BonusPower |
| DC-OK signal | yes |