Detail Information
Brand Name:
MTL
Model Number:
MTL5575
Product Type:
Intrinsic Safety Barriers & Surge Protection
Order No.:
MTL5575
Alternate Model:
mtl5575
Ambient Operating Temperature:
-20 to 60 °C
Ambient Storage Temperature:
-40 to 80 °C
Dimensions (L × H × W):
109.8 x 118.8 x 15.8 mm
Type:
THC or RTD input and alarm
Signal Type:
Temperature input
Signal Range:
-75mV to +75mV
Channels:
1
Power Supply:
20-35 Vdc
Current Consumption:
50mA
Galvanic Isolation:
250V rms between safe-area circuits and power supply
Area Classification:
Hazardous/Classified Locations
IECEx / ATEX Rating:
Zone 0
Standards:
IECEx/ATEX IEC
Humidity:
5-95% relative humidity
Mounting:
T-section 35mm DIN rail
Product Weight:
150 g
EAN:
3066227675808
Response Time:
Configurable (500ms default)
Output Signal Range:
4-20mA nominal into 600Ω max.
Terminal Capacity:
Accepts conductors of up to 2.5mm2 stranded or single-core
EMC:
EN61326
Safety Drive on Sensor Failure:
Upscale, downscale, or off
Configuration:
A personal computer running MTL PCS45 software with a PCL45USB serial interface
Cold Junction Compensation Error:
≤1.0°C
Cold Junction Compensation:
Automatic or selectable
Common Mode Rejection:
120 dB for 240V at 50 or 60 Hz
Series Mode Rejection:
40 dB for 50 or 60 Hz
Connection:
Crimp ferrules
RTD Excitation Current:
200µA
LED Indication:
Yes
LED Color - Power:
Green
LED Color - Status:
Yellow
Power Dissipation:
1.2W
Early Burnout:
Early burnout detection for thermocouples (when selected) Alarm trips when loop resistance increase is >50Ω
Input Signal:
THC types mV RTDs 2/3/4-wire
Maximum Load Resistance:
600Ω
Transfer Accuracy:
±11µA
Temperature Drift:
±0.6µA/°C
Highlight:

MTL5575 Intrinsic Safety Barriers & Surge Protection

,

MTL Intrinsic Safety Barriers & Surge Protection

Product Description
Eaton Crouse-Hinds series MTL5500 temperature converter, 1 channel, Temp input, 20-35Vdc, 1.2W, 50mA, Input signal: THC types, mV, RTDs 2/3/4-wire, -75mV to +75mV signal range, LED: Green = power, Yellow = status, THC or RTD input and alarm

MTL5575 — Eaton Crouse-Hinds series MTL5500 temperature converter, 1 channel, Temp input, 20-35Vdc, 1.2W, 50mA, Input signal: THC types, mV, RTDs 2/3/4-wire, -75mV to +75mV signal range, LED: Green = power, Yellow = status, THC or RTD input and alarm

Technical Specifications

Ambient Operating Temperature-20 to 60 °C
Ambient Storage Temperature-40 to 80 °C
Dimensions (L × H × W)109.8 x 118.8 x 15.8 mm
TypeTHC or RTD input and alarm
Signal TypeTemperature input
Signal Range-75mV to +75mV
Channels1
Power Supply20-35 Vdc
Current Consumption50mA
Galvanic Isolation250V rms between safe-area circuits and power supply
Area ClassificationHazardous/Classified Locations
IECEx / ATEX RatingZone 0
StandardsIECEx/ATEX IEC
Humidity5-95% relative humidity
MountingT-section 35mm DIN rail
Product Weight150 g
EAN3066227675808
Response TimeConfigurable (500ms default)
Output Signal Range4-20mA nominal into 600Ω max.
Terminal CapacityAccepts conductors of up to 2.5mm2 stranded or single-core

Key Features

  • 1 channel configuration
  • Temperature input with -75mV to +75mV signal range
  • Galvanic isolation rated 250V rms between safe-area circuits and power supply
  • Supply 20-35 Vdc, current consumption 50mA
  • Rated for Hazardous/Classified Locations
  • Hazardous area rating Zone 0
  • Ambient operating temperature -20 to 60 °C
  • Mounting: T-section 35mm DIN rail
  • Conforms to IECEx/ATEX IEC

Application

This module is intended for tHC or RTD input and alarm.

Installation is intended for hazardous/classified locations, in accordance with the manufacturer’s control drawings and the relevant national standards for intrinsically safe systems.

About the MTL5500 Series

The MTL5500 range is a DIN-rail intrinsic safety interface family from Eaton, providing galvanic isolation between safe-area control systems and field devices installed in hazardous areas.

Company Introduction

Shenzhen Glorient International Trade Co., Ltd. is a professional supplier of industrial automation equipment and industrial spare parts, established in Shenzhen in September 2020. We supply genuine original manufacturer products from brands including Schmersal, Endress+Hauser, SCHUNK, igus, Burkert, WIKA, PULS and Eaton UPS, covering industrial control, sensing & detection and spare parts.

Our team provides precise product selection and technical consultation backed by an efficient supply chain. Send us the model or part number and we will confirm price, availability and lead time within 24 hours. Products are shipped worldwide in standard export carton packaging, with T/T payment terms.

Customer Reviews

No reviews yet for this product. If you have used this part, please share your experience below — reviews are published after verification.

Write a Review

Only reviews from customers who have ordered or used this product are published. Every submission is checked before it appears.