Schmersal IFL 15-30L-10/01P (Order No: 101127034) is a genuine safety inductive sensors engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +70 °C; Amb...
Glorient offers competitive supply of Schmersal IFL 15-30L-10/01P, Order No: 101127034. Competitive pricing, fast quotation.
Schmersal IFL 15-30L-10/01P - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal IFL 15-30L-10/01P is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 140 g |
| Net weight | 140 g |
| Ambient temperature | -25 ... +70 °C |
| Ambient temperature, maximum | +70 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | DIN VDE 0660-208, EN IEC 60947-5-2, DIN 19234 |
| IP Degree of protection | IP67 |
| Certificates | CCC |
| Housing material | Brass |
| EAN (European Article Number) | 4030661278346 |
| Termination | Screw connection |
| Length of sensor | 118 mm |
| Switching element | NO contact or NC contact |
| Cable section, maximum | 1.5 mm² |
| Housing construction form | Cylinder, thread |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Note (General) | Instead of nuts, a mounting clamp can be provided. |
| Protection class | II |
| Other Parameters | Rated operating voltage: 10 ... 60 VDC | Integral system diagnostics, status: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-2 | ISO thread of the sensor: M30 | Restistance to shock: 30 g / 11 ms | Design of control elements: p-type | Protection class (Operating resource): 2 | Type of voltage range: DC | width across flats: 36 | Switching frequency, approx.: 100 | Length of cable: 2 | Material of the nuts: Brass | ACE reference article number: 171208 | Installation conditions (mechanical): not flush | Number of cable wires: 3 | Operating voltage, minimum: 10 | Protection circuit integrated: inductive interference protection | VOLT_RATED_OPERAT_RANGE_DC_MIN: 10 | Note (Integral System Diagnostics, status ): yellow LED | Tightening torque of nuts, maximum: 30 | Cable section: 1 mm² | Operating current: 400 | Operating voltage, maximum: 60 | VOLT_RATED_OPERAT_RANGE_DC_MAX: 60 | Operating voltage: 10 ... 60 VDC | Active area: Plastic | Housing coating material: nickel-plated |
In addition to IFL 15-30L-10/01P, Glorient also supplies:
| Gross weight | 140 g |
| Net weight | 140 g |
| Ambient temperature | -25 ... +70 °C |
| Ambient temperature, maximum | +70 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | DIN VDE 0660-208, EN IEC 60947-5-2, DIN 19234 |
| IP Degree of protection | IP67 |
| Certificates | CCC |
| Housing material | Brass |
| EAN (European Article Number) | 4030661278346 |
| Termination | Screw connection |
| Length of sensor | 118 mm |
| Switching element | NO contact or NC contact |
| Cable section, maximum | 1.5 mm² |
| Housing construction form | Cylinder, thread |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Note (General) | Instead of nuts, a mounting clamp can be provided. |
| Protection class | II |
| Other Parameters | Rated operating voltage: 10 ... 60 VDC | Integral system diagnostics, status: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-2 | ISO thread of the sensor: M30 | Restistance to shock: 30 g / 11 ms | Design of control elements: p-type | Protection class (Operating resource): 2 | Type of voltage range: DC | width across flats: 36 | Switching frequency, approx.: 100 | Length of cable: 2 | Material of the nuts: Brass | ACE reference article number: 171208 | Installation conditions (mechanical): not flush | Number of cable wires: 3 | Operating voltage, minimum: 10 | Protection circuit integrated: inductive interference protection | VOLT_RATED_OPERAT_RANGE_DC_MIN: 10 | Note (Integral System Diagnostics, status ): yellow LED | Tightening torque of nuts, maximum: 30 | Cable section: 1 mm² | Operating current: 400 | Operating voltage, maximum: 60 | VOLT_RATED_OPERAT_RANGE_DC_MAX: 60 | Operating voltage: 10 ... 60 VDC | Active area: Plastic | Housing coating material: nickel-plated |