Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AES 1112.3 24 VAC

Schmersal AES 1112.3 24 VAC

Model: AES 1112.3 24 VAC
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 18 views

Products Introduction

Schmersal AES 1112.3 24 VAC (Order No: 101128800) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Snaps onto standard DIN rail to .....

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AES 1112.3 24 VAC, Order No: 101128800. Competitive pricing, fast quotation.

Schmersal AES 1112.3 24 VAC - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AES 1112.3 24 VAC is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight120 g
Net weight120 g
Ambient temperature+0 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum+0 °C
StandardsEN IEC 60947-5-3
CertificatescULus
Housing materialGlass-fibre reinforced thermoplastic, ventilated
EAN (European Article Number)4030661059198
Mission time20
Mechanical lifetime, minimum10,000,000
Thermal test current4 A
Cable section, maximum2.5 mm²
Material of the contacts, electricalAgCdO
Number of safety contacts1
Resistance to vibrations10...55 Hz, Amplitude 0.35 mm, ± 15 %
Storage and transport temperature-25 ... +70 °C
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
MountingSnaps onto standard DIN rail to EN 60715
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Degree of pollution2
Other ParametersCurrent, Utilisation category DC-12: 0.1 | Switching capacity, maximum: 250 | Rated AC voltage for controls, 50 Hz, minimum: 20.4 | Rated AC voltage for controls, 60 Hz, minimum: 20.4 | Overvoltage category: III | Climatic stress: BG-GS-ET-14 | Rated operating voltage: 24 | Drop-out delay in case of emergency, typically: 20 | Current, Utilisation category DC-13: 2 | Integral system diagnostics, status: Yes | Reset after disconnection of supply voltage : Yes | Terminal designations: IEC/EN 60947-1 | Rated control voltage at AC 50 Hz, maximum: 26.4 | Cable section: 2.5 mm² | Height: 75 | Restistance to shock: 30 g / 11 ms | Voltage, Utilisation category DC-12: 24 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Pull-in delay at automatic start, maximum, typically: 100 | Conduction resistance, maximum: 40 | Number of normally open (NO): 1 | Automatic reset function: Yes | Voltage type: AC | Number of LEDs: 1 | Switching capacity, minimum: 10 | Rated control voltage at AC 60 Hz, maximum: 26.4 | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 2 A | Notice: for max. 50,000 switching cycles/year and max. 80% contact load | Terminal (mechanical): Screw terminals | IP Degree of protection of the installation space: IP54 | Drop-out delay in case of power failure, typically: 80 | Allowed type of cable: solid single-wire | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 3 A | Number of normally closed (NC): 2 | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | Pull-in delay at RESET, typically: 20 | Safety Integrity Level (SIL), suitable for applications in: 1 | IP Degree of protection of the enclosure: IP40 | PFH value: 1.14 x 10⁻⁶ | Width: 22.5 | Note (Contact resistance): in new state | Category: 1 | Performance Level, up to: c | Current, Utilisation category AC-15: 3 | Note (Wiring diagram): Monitoring one guard door: If only one magnetic safety sensor is connected to S1, the terminals S22, S32 and C of S2 must be bridged. | Note (applications): Safety sensor | Depth: 110 | Tightening torque of Clips: 0.6 | Electrical power consumption: 2.4 | Stop-Category: 0 | Voltage, Utilisation category AC-15: 230 | Indicated operating states: Authorised operation | Utilisation category DC-12: 24_0.1

More Schmersal Products from Glorient

In addition to AES 1112.3 24 VAC, Glorient also supplies:

SHGV/B01/201+BO Order No: 101198137
ACC-NRS-M4X12-FHS-3PCS Order No: 103051933
CSS 8-180-2P-E-L 10,0M Order No: 101195510
PWR-1000M Order No: 101130687
EX-RB Order No: 101205148
HEBEL 1H KPL. 235/236 Order No: 101090404
EX-BNS 33-02Z-2187-3GD Order No: 103050105
EX-M. 441-11Y-14-1276-2 Order No: 103011173
AZ 16-12ZIB1-M16-2053 Order No: 101150053
SMS 5-700-800 Order No: 101211564
MS 010-11E INSERT Order No: 131146370
RDTBL Order No: 101188245
BNS 300-01ZG-ST Order No: 101144214
BP 11 S Order No: 101057533
ESS21S1/EKM195 Order No: 103050349
EX-TR335-02Y Order No: 151212054
MKTA32-2949-1 Order No: 103016107
T4VH 355-02-2496 Order No: 101183945
AV21RHX20R-GB215 Order No: 103046657
KAPPE Z-125 ROT Order No: 101021498
RK-S-21-1ST8-1 Order No: 103013326
AZ 15/16-B1-1747 NACHRUESTSATZ Order No: 101093553
TS 232-11 SOCKEL KPL. Order No: 101113333
MV8H 330-11Y-M20-1366 Order No: 101160613
PS116-T11-ST-H200 Order No: 103006660
RDLWS/502D Order No: 103006538
SHGV/SR/RD1/101/41RT/RT+BOW Order No: 103035162
PS215-Z11-ST-H202 Order No: 103046699
BNS 180-12Z-2187-2 Order No: 101149207
TS 355-11Z-M20 Order No: 151169035

Related Guides

Gross weight120 g
Net weight120 g
Ambient temperature+0 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum+0 °C
StandardsEN IEC 60947-5-3
CertificatescULus
Housing materialGlass-fibre reinforced thermoplastic, ventilated
EAN (European Article Number)4030661059198
Mission time20
Mechanical lifetime, minimum10,000,000
Thermal test current4 A
Cable section, maximum2.5 mm²
Material of the contacts, electricalAgCdO
Number of safety contacts1
Resistance to vibrations10...55 Hz, Amplitude 0.35 mm, ± 15 %
Storage and transport temperature-25 ... +70 °C
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
MountingSnaps onto standard DIN rail to EN 60715
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Degree of pollution2
Other ParametersCurrent, Utilisation category DC-12: 0.1 | Switching capacity, maximum: 250 | Rated AC voltage for controls, 50 Hz, minimum: 20.4 | Rated AC voltage for controls, 60 Hz, minimum: 20.4 | Overvoltage category: III | Climatic stress: BG-GS-ET-14 | Rated operating voltage: 24 | Drop-out delay in case of emergency, typically: 20 | Current, Utilisation category DC-13: 2 | Integral system diagnostics, status: Yes | Reset after disconnection of supply voltage : Yes | Terminal designations: IEC/EN 60947-1 | Rated control voltage at AC 50 Hz, maximum: 26.4 | Cable section: 2.5 mm² | Height: 75 | Restistance to shock: 30 g / 11 ms | Voltage, Utilisation category DC-12: 24 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Pull-in delay at automatic start, maximum, typically: 100 | Conduction resistance, maximum: 40 | Number of normally open (NO): 1 | Automatic reset function: Yes | Voltage type: AC | Number of LEDs: 1 | Switching capacity, minimum: 10 | Rated control voltage at AC 60 Hz, maximum: 26.4 | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 2 A | Notice: for max. 50,000 switching cycles/year and max. 80% contact load | Terminal (mechanical): Screw terminals | IP Degree of protection of the installation space: IP54 | Drop-out delay in case of power failure, typically: 80 | Allowed type of cable: solid single-wire | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 3 A | Number of normally closed (NC): 2 | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | Pull-in delay at RESET, typically: 20 | Safety Integrity Level (SIL), suitable for applications in: 1 | IP Degree of protection of the enclosure: IP40 | PFH value: 1.14 x 10⁻⁶ | Width: 22.5 | Note (Contact resistance): in new state | Category: 1 | Performance Level, up to: c | Current, Utilisation category AC-15: 3 | Note (Wiring diagram): Monitoring one guard door: If only one magnetic safety sensor is connected to S1, the terminals S22, S32 and C of S2 must be bridged. | Note (applications): Safety sensor | Depth: 110 | Tightening torque of Clips: 0.6 | Electrical power consumption: 2.4 | Stop-Category: 0 | Voltage, Utilisation category AC-15: 230 | Indicated operating states: Authorised operation | Utilisation category DC-12: 24_0.1