AZM 170-02ZRI-ST-B5-2197 24VAC/DC

Schmersal AZM 170-02ZRI-ST-B5-2197 24VAC/DC

Model: AZM 170-02ZRI-ST-B5-2197 24VAC/DC
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 20 views

Products Introduction

Schmersal AZM 170-02ZRI-ST-B5-2197 24VAC/DC (Order No: 101144339) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient t...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM 170-02ZRI-ST-B5-2197 24VAC/DC, Order No: 101144339. Competitive pricing, fast quotation.

Schmersal AZM 170-02ZRI-ST-B5-2197 24VAC/DC - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM 170-02ZRI-ST-B5-2197 24VAC/DC is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight296 g
Net weight296 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078493 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-1
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661132822
Mission time20
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching element2 NC contact
Switching principleslow action, positive break NC contact
Width of sensor108 mm
Thermal test current4 A
Height of sensor75.5 mm
Material of the contacts, electricalSilver
Utilisation category DC-1324 VDC / 4 A
Max. fuse rating4 A gG D-fuse
Utilisation category AC-15230 VAC / 4 A
Maximum switching frequency1,000 Hz
Number of safety contacts2
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteTorx T10
Number of auxiliary contacts1
TracepartsYes
Storage and transport temperature-25 ... +85 °C
Scope of deliveryThe actuator is included in the scope of delivery
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
MountingScrews
Note (General)minimum actuating radius on hinged guards in line with the plane of the actuator 200 mm
Degree of pollution3
Protection classII
Other ParametersOvervoltage category: III | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Test pulse interval, minimum: 50 | Electrical power consumption, maximum: 12 | Power to unlock: Yes | Note (Manual release): Additional manual release on side | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Positive break force per NC contact, minimum: 8.5 | Cable section: 0.75 mm² ... 1 mm² | Voltage, Utilisation category DC-13: 24 | Working principle: electromechanical | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | Actuating radius, minimum: 140 | CADENAS: Yes | Type of the fixing screws: 2x M4 | Latching force: 30 | Voltage, Utilisation category AC-15: 230 | Positive break travel: 11 | Material of the actuator: Stainless steel | Note (Switching element): Change-over contact with double break, type Zb or 2 NC or 3 NC or 4 NC contacts, with galvanically separated contact bridges | Coding: Individual coding | Current, Utilisation category AC-15: 4 | Coding level according to EN ISO 14119: High | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Manual release: Yes | Category: 3 | Number of actuating directions: 2 | Note (applications): removable guard | Positive break force, minimum: 17 | Current, Utilisation category DC-13: 4 | Permissible installation altitude above sea level, maximum: 2,000 | Connector position : Bottom | Tightening torque of the fastening screws for the housing cover, minimum: 0.7

More Schmersal Products from Glorient

In addition to AZM 170-02ZRI-ST-B5-2197 24VAC/DC, Glorient also supplies:

BN 21-11Z/1T/KS1-964 Order No: 101057121
MS 6610-11-K-Z Order No: 101055454
BNS 33-11ZG 5,0M Order No: 101110010
AZM40Z-I1-ST-1P2P Order No: 103034188
NDTP30BL Order No: 103005364
ESS21S1/EKM176 Order No: 103050329
PS316-T12-K360 Order No: 103015156
SEP09.0.3.0.22/95.E1 Order No: 103008215
EX-T3K335-11Y Order No: 101212078
SLG 420-R0800-03-RFH Order No: 101207375
TS 236-02Z-1894 Order No: 151098641
SHGV/R1.1/214+BO Order No: 103003812
SLC440-ER-0490-14-H1 Order No: 103039581
SLC440COM-E-0490-30-1700 Order No: 103040501
NWSE3K/CA20-A401 Order No: 103012824
SLC440-ER-0250-14-01 Order No: 101216616
TL 441-11Y-1801-RMS Order No: 101195076
AZM400Z-ST-1P2P Order No: 103003590
ZS 232-02 SOCKEL KPL. Order No: 151113332
MKTC52/KG/WKT-26 Order No: 101190203
CSS 8-180-2P-E-L Order No: 101167896
AZ 16-03ZIB1-M16-2177 Order No: 101150059
SVM1/SR/60-6/200RT/WS/A Order No: 103010865
T4V7H 355-11Z-2138 Order No: 153000559
G150-150Z22/22Y Order No: 101166880
BDF200-B-11-LTBU-B-B Order No: 101215666
MZM 100 B ST2-SD2PREM-A Order No: 101211153

Related Guides

Gross weight296 g
Net weight296 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078493 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-1
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661132822
Mission time20
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching element2 NC contact
Switching principleslow action, positive break NC contact
Width of sensor108 mm
Thermal test current4 A
Height of sensor75.5 mm
Material of the contacts, electricalSilver
Utilisation category DC-1324 VDC / 4 A
Max. fuse rating4 A gG D-fuse
Utilisation category AC-15230 VAC / 4 A
Maximum switching frequency1,000 Hz
Number of safety contacts2
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteTorx T10
Number of auxiliary contacts1
TracepartsYes
Storage and transport temperature-25 ... +85 °C
Scope of deliveryThe actuator is included in the scope of delivery
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
MountingScrews
Note (General)minimum actuating radius on hinged guards in line with the plane of the actuator 200 mm
Degree of pollution3
Protection classII
Other ParametersOvervoltage category: III | Tightening torque of the fastening screws for the housing cover, maximum: 1 | Test pulse interval, minimum: 50 | Electrical power consumption, maximum: 12 | Power to unlock: Yes | Note (Manual release): Additional manual release on side | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Positive break force per NC contact, minimum: 8.5 | Cable section: 0.75 mm² ... 1 mm² | Voltage, Utilisation category DC-13: 24 | Working principle: electromechanical | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | Actuating radius, minimum: 140 | CADENAS: Yes | Type of the fixing screws: 2x M4 | Latching force: 30 | Voltage, Utilisation category AC-15: 230 | Positive break travel: 11 | Material of the actuator: Stainless steel | Note (Switching element): Change-over contact with double break, type Zb or 2 NC or 3 NC or 4 NC contacts, with galvanically separated contact bridges | Coding: Individual coding | Current, Utilisation category AC-15: 4 | Coding level according to EN ISO 14119: High | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Manual release: Yes | Category: 3 | Number of actuating directions: 2 | Note (applications): removable guard | Positive break force, minimum: 17 | Current, Utilisation category DC-13: 4 | Permissible installation altitude above sea level, maximum: 2,000 | Connector position : Bottom | Tightening torque of the fastening screws for the housing cover, minimum: 0.7