Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

MZM 100 ST2-SD2PREM-A

Schmersal MZM 100 ST2-SD2PREM-A

Model: MZM 100 ST2-SD2PREM-A
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 18 views

Products Introduction

Schmersal MZM 100 ST2-SD2PREM-A (Order No: 101211146) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +55 °C; Amb...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal MZM 100 ST2-SD2PREM-A, Order No: 101211146. Competitive pricing, fast quotation.

Schmersal MZM 100 ST2-SD2PREM-A - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal MZM 100 ST2-SD2PREM-A is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight640 g
Net weight640 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661389486
Mission time20
TerminationConnector M12, 8-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor177.5 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Latching force, maximum: 115 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | External wire and device fuse rating: 2 A gG (Connector M12, 8-pole) | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Serial diagnostics: Yes | Wiring capacitance: 50 | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Number of series-wiring of sensors: 31 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | Latching force, minimum: 45 | CADENAS: Yes | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT serial diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | FORCE_LATCH_GPV: 45 ... 115 N | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Designation, Serial diagnostic SD: OUT | Current consumption with magnet ON, average : 350 | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Current, Utilisation category DC-13: 0.25 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole | Permissible installation altitude above sea level, maximum: 2,000 | PIN 8: IN serial diagnostic input | Safety Integrity Level (SIL), suitable for applications in: 3 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2 | Operation current: 150

More Schmersal Products from Glorient

In addition to MZM 100 ST2-SD2PREM-A, Glorient also supplies:

SHGV/LD1/211/44+BOW Order No: 101213480
SVM1/SR/65-10/165GN/WS/A Order No: 101218088
SHGV/ESS21S2/72/103 Order No: 101205794
TR 336-20ZH-M20-2049 Order No: 151165098
T. 441-11Y-1224 Order No: 101109329
SLC240COM-ER-0890-35 Order No: 103016257
WKTP32 Order No: 101007589
SVE3/303/303/303-3Ö-24VDC Order No: 103039338
T-RFID-0 KPL. Order No: 101185887
TS 335-02Z Order No: 151082520
EX-RDLBL Order No: 101197352
BNS 36 STW-AS-R Order No: 101194958
EX-SLC440-ER-1370-14 Order No: 103047650
TESK-ZL Order No: 103002966
MZM 100 ST-1P2PWM-A Order No: 101209061
IFL 13-390-10YA (M25) Order No: 103001689
PS216-T20-ST-N200 Order No: 103027427
SHGV/L01/153+BO Order No: 101197834
TESK-SI-11ST1 Order No: 103005751
ZS 236-02ZR-M20-2086 Order No: 151162529
SMS 4-430-936-0272 Order No: 103033164
SHGV/L01/102+BO Order No: 101197783
T4VH 336-20Z-M20 Order No: 151168151
ESS21S1/EKM172 Order No: 103050325
AZM300B-I2-ST-1P2P-A-T Order No: 103010555
SLC240COM-ER-0330-30 Order No: 103016156
M 689-11-1-P4 Order No: 101144980
A-K4P-M12P-S-G-5M-BK-2-X-T-4 Order No: 103013430
G50-050M22/Z22Y-1600-1-1368-3 Order No: 103013015

Related Guides

Gross weight640 g
Net weight640 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661389486
Mission time20
TerminationConnector M12, 8-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor177.5 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Latching force, maximum: 115 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | External wire and device fuse rating: 2 A gG (Connector M12, 8-pole) | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Serial diagnostics: Yes | Wiring capacitance: 50 | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Number of series-wiring of sensors: 31 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | Latching force, minimum: 45 | CADENAS: Yes | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT serial diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | FORCE_LATCH_GPV: 45 ... 115 N | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Designation, Serial diagnostic SD: OUT | Current consumption with magnet ON, average : 350 | Rated operating voltage: 24 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | Current, Utilisation category DC-13: 0.25 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole | Permissible installation altitude above sea level, maximum: 2,000 | PIN 8: IN serial diagnostic input | Safety Integrity Level (SIL), suitable for applications in: 3 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2 | Operation current: 150