Schmersal SLC440COM-ER-0490-30 (Order No: 103003942) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -10 ... +50 °C; Amb...
Glorient offers competitive supply of Schmersal SLC440COM-ER-0490-30, Order No: 103003942. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to SLC440COM-ER-0490-30, Glorient also supplies:
| Gross weight | 920 g |
| Net weight | 920 g |
| Ambient temperature | -10 ... +50 °C |
| Ambient temperature, maximum | +50 °C |
| Ambient temperature, minimum | -10 °C |
| Standards | EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661435206 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Height of sensor | 531 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Reaction time, maximum: 10 | Bluetooth transmission frequency: 2.400 … 2.483 | Number of fail-safe digital outputs: 2 | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Designation, Control inputs: Release / restart interlock | Bluetooth transmission power, maximum: 2 | Radiation emission level to EN 12198-1: Category 0 | EPLAN: Yes | Integral system diagnostics, status: Yes | Switching voltage: 0 … 2 V (LOW) | PIN 4: Do not connect a signal (do not wire) | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Note (Software Version): as of 2024 Version 4.0 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | LED position: Emitter | PIN 2: OSSD 1 Safety output 1 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | PIN 5: Release/restart interlock Acknowledgement restart interlock | CADENAS: Yes | Restart interlock (manual reset): Yes | TOL_VOLT_OPERAT_DC_MAX: 20 | Range, protection field, maximum: 10 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Recommended safety switchgear: SRB-E 301 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | TOL_VOLT_OPERAT_DC_MIN: -20 | Note (applications): protective mode/automatic, restart interlock, setting mode | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Terminal connector, Recipient: Connector plug M12, 5-pole | Safety Integrity Level (SIL), suitable for applications in: 3 | Height of the protection field: 490 | Rated operating voltage: 24 | LED status: transmitting and status | Connection: Emitter | Test pulse interval, typical: 750 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Detection ability for test bodies at v = 1.6 m/s: 30 | Number of beams: 24 | Safety type in accordance with IEC 61496-1: 4 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |