Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM 161SK-12/12RIAT-024G-B1

Schmersal AZM 161SK-12/12RIAT-024G-B1

Model: AZM 161SK-12/12RIAT-024G-B1
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 18 views

Products Introduction

Schmersal AZM 161SK-12/12RIAT-024G-B1 (Order No: 103000011) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Screws; Ambient tempera...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM 161SK-12/12RIAT-024G-B1, Order No: 103000011. Competitive pricing, fast quotation.

Schmersal AZM 161SK-12/12RIAT-024G-B1 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM 161SK-12/12RIAT-024G-B1 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight490 g
Net weight490 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078481 °C
Ambient temperature, minimum-25 °C
StandardsEN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1, BG-GS-ET-19
IP Degree of protectionIP67
CertificatesIFA, cULus, CCC
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661419671
Mission time20
TerminationScrew terminals
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching elementNO contact, NC contact
Switching principleslow action, positive break NC contact
Width of sensor130 mm
Thermal test current6 A
Cable section, maximum1.5 mm²
Height of sensor90 mm
Material of the contacts, electricalSilver
Utilisation category DC-1324 VDC / 2.5 A
Max. fuse rating6 A gG D-fuse to DIN EN 60269-1
Utilisation category AC-15230 VAC / 4 A
Maximum switching frequency1,000 Hz
Cable section, minimum0.25 mm²
Number of safety contacts4 / 5
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteAll indications including the conductor ferrules.
Number of auxiliary contacts1 / 2
TracepartsYes
Storage and transport temperature-30 ... +85 °C
Scope of deliveryThe actuator is included in the scope of delivery
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-30 °C
MountingScrews
Protection classII
Other ParametersVoltage, Utilisation category DC-13: 24 | Voltage, Utilisation category AC-15: 230 | Test pulse interval, minimum: 50 | Number of actuating directions: 3 | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Integral system diagnostics, status: Yes | Power to lock: Yes | Working principle: electromechanical | Emergency exit: Yes | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | CADENAS: Yes | Latching force: 30 | Positive break travel: 10 | Current, Utilisation category DC-13: 4 | Material of the actuator: Stainless steel | Type of the fixing screws: 3x M6 | Positive break force, minimum: 20 | Allowed type of cable: solid single-wire | Coding: Individual coding | Current, Utilisation category AC-15: 4 | Electrical power consumption, maximum: 10 | Coding level according to EN ISO 14119: High | Note (Emergency exit): In case of emergency actuation from within the hazardous area | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Manual release: Yes | Tightening torque of electrical connection, maximum: 0.5 | Note (Manual release): For maintenance, installation, etc. | Category: 3 | Actuating play in direction of actuation: 5.5 | Note (applications): removable guard | Tightening torque of the fastening screws for the housing cover: 0.6 | Positive break force per NC contact, minimum: 10 | Permissible installation altitude above sea level, maximum: 2,000 | Tightening torque of electrical connection, minimum: 0.4 | Cable entry: 2 x M16 x 1.5 | Actuating radius, minimum: 150

More Schmersal Products from Glorient

In addition to AZM 161SK-12/12RIAT-024G-B1, Glorient also supplies:

SVE3/202/202/202-230VAC Order No: 103015350
SLC240COM-ER-0890-30 Order No: 103016165
T4K 236-11Z-U180-M16-1297/1894 Order No: 151163906
SVE1/252EDTRWS/EMLWS-24VDC Order No: 103016085
2XM 6600-10-K 2,3M -1465-2 Order No: 101142450
EWST32ÖBB Order No: 101194729
SECHSKANTMUTTER M5-MS Order No: 101071898
SVE1/SR/103RT/RT-24VDC Order No: 101213473
SLC240COM-ER-0890-14 Order No: 103016234
AZM 161SK-12/12KAN-024 Order No: 101184610
ESS21S12/EKM43 Order No: 101205690
MV3H 017-22Y Order No: 131060371
EX-BNS 33-02ZG-2187-3GD 10M Order No: 103050104
EDP40.VSW Order No: 101006176
BN 32-R-1279-2 2,5M Order No: 101091419
SLC440-ER-0410-14-01 Order No: 101216618
SHGV/B01/116+BOR Order No: 103003219
EDR40BL Order No: 101006326
T. 064-30Y Order No: 101060756
BDF200-FB-NH-LT-LT-B-2875 Order No: 103038089
T2Z 067-11Y-UE Order No: 103013512
TK 236-11Z-M20 Order No: 151168165
M 6800-11-5-8V Order No: 101061856
SHGV/LD1/263/363+BOW Order No: 103040314
AZ 16 ST1-AS RB ASI-SAW Order No: 101167265
FIXIERBLECH -2270 VEREDELT Order No: 101157077
BN 65-RZ/V 0,170M Order No: 101096431
T. 441-11Y-1801 Order No: 101209137
SHGV/RD1/207/37+BOW Order No: 101198571

Related Guides

Gross weight490 g
Net weight490 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000078481 °C
Ambient temperature, minimum-25 °C
StandardsEN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1, BG-GS-ET-19
IP Degree of protectionIP67
CertificatesIFA, cULus, CCC
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661419671
Mission time20
TerminationScrew terminals
Mechanical lifetime, minimum1,000,000
Length of sensor30 mm
Switching elementNO contact, NC contact
Switching principleslow action, positive break NC contact
Width of sensor130 mm
Thermal test current6 A
Cable section, maximum1.5 mm²
Height of sensor90 mm
Material of the contacts, electricalSilver
Utilisation category DC-1324 VDC / 2.5 A
Max. fuse rating6 A gG D-fuse to DIN EN 60269-1
Utilisation category AC-15230 VAC / 4 A
Maximum switching frequency1,000 Hz
Cable section, minimum0.25 mm²
Number of safety contacts4 / 5
Required rated short-circuit current1,000 A
Actuating speed, maximum2 m/s
NoteAll indications including the conductor ferrules.
Number of auxiliary contacts1 / 2
TracepartsYes
Storage and transport temperature-30 ... +85 °C
Scope of deliveryThe actuator is included in the scope of delivery
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-30 °C
MountingScrews
Protection classII
Other ParametersVoltage, Utilisation category DC-13: 24 | Voltage, Utilisation category AC-15: 230 | Test pulse interval, minimum: 50 | Number of actuating directions: 3 | Test pulse duration, maximum: 5 | Rated control voltage: 24 | Note (Relative humidity): non-condensing | Integral system diagnostics, status: Yes | Power to lock: Yes | Working principle: electromechanical | Emergency exit: Yes | Protection class (Operating resource): 2 | Magnet switch-on time: 100 | CADENAS: Yes | Latching force: 30 | Positive break travel: 10 | Current, Utilisation category DC-13: 4 | Material of the actuator: Stainless steel | Type of the fixing screws: 3x M6 | Positive break force, minimum: 20 | Allowed type of cable: solid single-wire | Coding: Individual coding | Current, Utilisation category AC-15: 4 | Electrical power consumption, maximum: 10 | Coding level according to EN ISO 14119: High | Note (Emergency exit): In case of emergency actuation from within the hazardous area | Please note:: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. | Performance Level, up to: c | Manual release: Yes | Tightening torque of electrical connection, maximum: 0.5 | Note (Manual release): For maintenance, installation, etc. | Category: 3 | Actuating play in direction of actuation: 5.5 | Note (applications): removable guard | Tightening torque of the fastening screws for the housing cover: 0.6 | Positive break force per NC contact, minimum: 10 | Permissible installation altitude above sea level, maximum: 2,000 | Tightening torque of electrical connection, minimum: 0.4 | Cable entry: 2 x M16 x 1.5 | Actuating radius, minimum: 150