Schmersal SLC240COM-ER-0890-14 (Order No: 103016234) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -10 ... +50 °C; Amb...
Glorient offers competitive supply of Schmersal SLC240COM-ER-0890-14, Order No: 103016234. Competitive pricing, fast quotation.
Schmersal SLC240COM-ER-0890-14 - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal SLC240COM-ER-0890-14 is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 1,540 g |
| Net weight | 1,540 g |
| Ambient temperature | -10 ... +50 °C |
| Ambient temperature, maximum | +50 °C |
| Ambient temperature, minimum | -10 °C |
| Standards | EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661507057 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Height of sensor | 931 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Number of fail-safe digital outputs: 2 | Category: 2 | Reaction time, maximum: 20 | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Radiation emission level to EN 12198-1: Category 0 | PIN 4: Slave Series wiring | Designation, Control inputs: Reset and Test | Integral system diagnostics, status: Yes | Switching voltage: 0 … 2 V (LOW) | PIN 5: Reset Restart interlock (manual reset) | Tolerance, percentage: 10 | PIN 2: Test Test input | Rated operating current, Emitter: 200 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | Switching thresholds: 24 V (HIGH) | TOL_VOLT_OPERAT_DC_MIN: -10 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | LED position: Receiver | Load inductance, maximum: 2 | Safety Integrity Level (SIL), suitable for applications in: 1 | Detection ability for test bodies at v = 1.6 m/s: 14 | CADENAS: Yes | Blanking function: Yes | Restart interlock (manual reset): Yes | Classification ZVEI CB24I, Sink: C1 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | ACE reference article number: 11930759 | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Cascadable: Yes | Safety type in accordance with IEC 61496-1: 2 | Terminal connector, Recipient: Connector plug M12, 5-pole | Number of beams: 88 | Performance Level, up to: c | Rated operating voltage: 24 | Voltage type: DC | Connection: Emitter | Test pulse interval, typical: 750 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Note (Software Version): as of 2017 Version 1.0 | Master- or Slave-function: Yes | Range, protection field, maximum: 7 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | LED status: OSSD ON, OSSD OFF, Restart interlock, Error, Parameter setting, Alignment kit, Indication of signal quality | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Height of the protection field: 890 |
In addition to SLC240COM-ER-0890-14, Glorient also supplies:
Schmersal safety switchgear is widely used in machine guarding and process safety applications, including CNC machining centres, robotic cell fencing, packaging and bottling lines, material handling equipment, press and forming machinery, and automated assembly stations. Choosing the correct interlock or position switch with the right contact rating and coding level is essential to meeting your machine's PL or SIL requirements.
Yes. All Schmersal products we supply are 100% genuine and new in original factory packing, sourced from authorised supply channels with full factory warranty.
Schmersal safety switches use positive-break (Zwangsöffnung) contacts designed to EN 60947-5-1, which guarantee contact separation even if the actuator is forced out or the spring fails. This is the core requirement for safety circuits rated up to PL e according to EN ISO 13849-1.
Send us the part number through the quote form and our team will respond within 24 hours with pricing, stock availability and estimated delivery time.
| Gross weight | 1,540 g |
| Net weight | 1,540 g |
| Ambient temperature | -10 ... +50 °C |
| Ambient temperature, maximum | +50 °C |
| Ambient temperature, minimum | -10 °C |
| Standards | EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661507057 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Height of sensor | 931 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Number of fail-safe digital outputs: 2 | Category: 2 | Reaction time, maximum: 20 | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Radiation emission level to EN 12198-1: Category 0 | PIN 4: Slave Series wiring | Designation, Control inputs: Reset and Test | Integral system diagnostics, status: Yes | Switching voltage: 0 … 2 V (LOW) | PIN 5: Reset Restart interlock (manual reset) | Tolerance, percentage: 10 | PIN 2: Test Test input | Rated operating current, Emitter: 200 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | Switching thresholds: 24 V (HIGH) | TOL_VOLT_OPERAT_DC_MIN: -10 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | LED position: Receiver | Load inductance, maximum: 2 | Safety Integrity Level (SIL), suitable for applications in: 1 | Detection ability for test bodies at v = 1.6 m/s: 14 | CADENAS: Yes | Blanking function: Yes | Restart interlock (manual reset): Yes | Classification ZVEI CB24I, Sink: C1 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | ACE reference article number: 11930759 | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Cascadable: Yes | Safety type in accordance with IEC 61496-1: 2 | Terminal connector, Recipient: Connector plug M12, 5-pole | Number of beams: 88 | Performance Level, up to: c | Rated operating voltage: 24 | Voltage type: DC | Connection: Emitter | Test pulse interval, typical: 750 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Note (Software Version): as of 2017 Version 1.0 | Master- or Slave-function: Yes | Range, protection field, maximum: 7 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | LED status: OSSD ON, OSSD OFF, Restart interlock, Error, Parameter setting, Alignment kit, Indication of signal quality | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Height of the protection field: 890 |