Schmersal SLC440COM-ER-0490-35 (Order No: 103004001) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -10 ... +50 °C; Amb...
Glorient offers competitive supply of Schmersal SLC440COM-ER-0490-35, Order No: 103004001. Competitive pricing, fast quotation.
Schmersal SLC440COM-ER-0490-35 - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal SLC440COM-ER-0490-35 is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 920 g |
| Net weight | 920 g |
| Ambient temperature | -10 ... +50 °C |
| Ambient temperature, maximum | +50 °C |
| Ambient temperature, minimum | -10 °C |
| Standards | EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661435404 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Height of sensor | 531 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Reaction time, maximum: 10 | Bluetooth transmission frequency: 2.400 … 2.483 | Number of fail-safe digital outputs: 2 | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Designation, Control inputs: Release / restart interlock | Bluetooth transmission power, maximum: 2 | Radiation emission level to EN 12198-1: Category 0 | EPLAN: Yes | Integral system diagnostics, status: Yes | Number of beams: 16 | Switching voltage: 0 … 2 V (LOW) | PIN 4: Do not connect a signal (do not wire) | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Note (Software Version): as of 2024 Version 4.0 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | LED position: Emitter | PIN 2: OSSD 1 Safety output 1 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | PIN 5: Release/restart interlock Acknowledgement restart interlock | CADENAS: Yes | Restart interlock (manual reset): Yes | TOL_VOLT_OPERAT_DC_MAX: 20 | ACE reference article number: 1193066901 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Recommended safety switchgear: SRB-E 301 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | TOL_VOLT_OPERAT_DC_MIN: -20 | Note (applications): protective mode/automatic, restart interlock, setting mode | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Terminal connector, Recipient: Connector plug M12, 5-pole | Safety Integrity Level (SIL), suitable for applications in: 3 | Height of the protection field: 490 | Rated operating voltage: 24 | LED status: transmitting and status | Connection: Emitter | Test pulse interval, typical: 750 | Detection ability for test bodies at v = 1.6 m/s: 35 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Range, protection field, maximum: 7 | Safety type in accordance with IEC 61496-1: 4 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |
In addition to SLC440COM-ER-0490-35, Glorient also supplies:
| Gross weight | 920 g |
| Net weight | 920 g |
| Ambient temperature | -10 ... +50 °C |
| Ambient temperature, maximum | +50 °C |
| Ambient temperature, minimum | -10 °C |
| Standards | EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661435404 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Height of sensor | 531 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Reaction time, maximum: 10 | Bluetooth transmission frequency: 2.400 … 2.483 | Number of fail-safe digital outputs: 2 | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Designation, Control inputs: Release / restart interlock | Bluetooth transmission power, maximum: 2 | Radiation emission level to EN 12198-1: Category 0 | EPLAN: Yes | Integral system diagnostics, status: Yes | Number of beams: 16 | Switching voltage: 0 … 2 V (LOW) | PIN 4: Do not connect a signal (do not wire) | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Note (Software Version): as of 2024 Version 4.0 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | LED position: Emitter | PIN 2: OSSD 1 Safety output 1 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | PIN 5: Release/restart interlock Acknowledgement restart interlock | CADENAS: Yes | Restart interlock (manual reset): Yes | TOL_VOLT_OPERAT_DC_MAX: 20 | ACE reference article number: 1193066901 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Recommended safety switchgear: SRB-E 301 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | TOL_VOLT_OPERAT_DC_MIN: -20 | Note (applications): protective mode/automatic, restart interlock, setting mode | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Terminal connector, Recipient: Connector plug M12, 5-pole | Safety Integrity Level (SIL), suitable for applications in: 3 | Height of the protection field: 490 | Rated operating voltage: 24 | LED status: transmitting and status | Connection: Emitter | Test pulse interval, typical: 750 | Detection ability for test bodies at v = 1.6 m/s: 35 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Range, protection field, maximum: 7 | Safety type in accordance with IEC 61496-1: 4 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e |