Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

SLC440COM-ER-0490-35

Schmersal SLC440COM-ER-0490-35

Model: SLC440COM-ER-0490-35
Brand: Schmersal
Category: Safety Light Curtains
Views: 25 views

Products Introduction

Schmersal SLC440COM-ER-0490-35 (Order No: 103004001) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -10 ... +50 °C; Amb...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal SLC440COM-ER-0490-35, Order No: 103004001. Competitive pricing, fast quotation.

Schmersal SLC440COM-ER-0490-35 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal SLC440COM-ER-0490-35 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight920 g
Net weight920 g
Ambient temperature-10 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-10 °C
StandardsEN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661435404
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
Height of sensor531 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Bluetooth transmission frequency: 2.400 … 2.483 | Number of fail-safe digital outputs: 2 | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Designation, Control inputs: Release / restart interlock | Bluetooth transmission power, maximum: 2 | Radiation emission level to EN 12198-1: Category 0 | EPLAN: Yes | Integral system diagnostics, status: Yes | Number of beams: 16 | Switching voltage: 0 … 2 V (LOW) | PIN 4: Do not connect a signal (do not wire) | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Note (Software Version): as of 2024 Version 4.0 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | LED position: Emitter | PIN 2: OSSD 1 Safety output 1 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | PIN 5: Release/restart interlock Acknowledgement restart interlock | CADENAS: Yes | Restart interlock (manual reset): Yes | TOL_VOLT_OPERAT_DC_MAX: 20 | ACE reference article number: 1193066901 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Recommended safety switchgear: SRB-E 301 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | TOL_VOLT_OPERAT_DC_MIN: -20 | Note (applications): protective mode/automatic, restart interlock, setting mode | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Terminal connector, Recipient: Connector plug M12, 5-pole | Safety Integrity Level (SIL), suitable for applications in: 3 | Height of the protection field: 490 | Rated operating voltage: 24 | LED status: transmitting and status | Connection: Emitter | Test pulse interval, typical: 750 | Detection ability for test bodies at v = 1.6 m/s: 35 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Range, protection field, maximum: 7 | Safety type in accordance with IEC 61496-1: 4 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e

More Schmersal Products from Glorient

In addition to SLC440COM-ER-0490-35, Glorient also supplies:

ZV10H 236-11Z-M16 Order No: 151167150
EWST32ÖBB Order No: 101194729
NDTWS/501D Order No: 101210236
SVE1/100-3Ö-24VDC Order No: 103031974
ESS32S2 Order No: 101006391
BNS 260-11/01ZG-L 2,0M Order No: 101191002
EFK10.2 Order No: 101022276
VMLHGB/411D M. L30/5 80MA 24V Order No: 101190975
EX-SLC440-ER-0490-14 Order No: 103047645
NDLP30GB Order No: 103005365
HEBEL 2H KPL. 302 EP. 1,0 Order No: 101064218
ESS21S1/EKM32 Order No: 101190242
DRNGB Order No: 101006988
Z4V7H 335-11Z-M20-2163 Order No: 101168262
SHGV/L01/107+BO Order No: 101197788
SVE3/209/209/209-24VDC Order No: 101197531
KA-0904 Order No: 101207728
BNS 36-11ZG-ST-L Order No: 101190048
TZFW4OES24VDC Order No: 131173818
EDTRT/SWELOX. Order No: 101195205
MKSA32/WKT-19.4 Order No: 101189200
KLAPPENPROFIL L1 = 150 Order No: 101204951
RK-S-21-1ST8-1 Order No: 103013326
DTNBL/MU/FS30 Order No: 101194484
AZ/AZM 200-B30-LTAG2P20 Order No: 101189020
RWSE3K.1 Order No: 101195857
EX-T4V7H335-11Y-2138 Order No: 101212070
E-KB9WS/L00841096 Order No: 101218414

Related Guides

Gross weight920 g
Net weight920 g
Ambient temperature-10 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-10 °C
StandardsEN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661435404
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
Height of sensor531 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Bluetooth transmission frequency: 2.400 … 2.483 | Number of fail-safe digital outputs: 2 | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Designation, Control inputs: Release / restart interlock | Bluetooth transmission power, maximum: 2 | Radiation emission level to EN 12198-1: Category 0 | EPLAN: Yes | Integral system diagnostics, status: Yes | Number of beams: 16 | Switching voltage: 0 … 2 V (LOW) | PIN 4: Do not connect a signal (do not wire) | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Note (Software Version): as of 2024 Version 4.0 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | LED position: Emitter | PIN 2: OSSD 1 Safety output 1 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | PIN 5: Release/restart interlock Acknowledgement restart interlock | CADENAS: Yes | Restart interlock (manual reset): Yes | TOL_VOLT_OPERAT_DC_MAX: 20 | ACE reference article number: 1193066901 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Recommended safety switchgear: SRB-E 301 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | TOL_VOLT_OPERAT_DC_MIN: -20 | Note (applications): protective mode/automatic, restart interlock, setting mode | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Terminal connector, Recipient: Connector plug M12, 5-pole | Safety Integrity Level (SIL), suitable for applications in: 3 | Height of the protection field: 490 | Rated operating voltage: 24 | LED status: transmitting and status | Connection: Emitter | Test pulse interval, typical: 750 | Detection ability for test bodies at v = 1.6 m/s: 35 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Range, protection field, maximum: 7 | Safety type in accordance with IEC 61496-1: 4 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e