Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

SLC440COM-ER-0730-35

Schmersal SLC440COM-ER-0730-35

Model: SLC440COM-ER-0730-35
Brand: Schmersal
Category: Safety Light Curtains
Views: 25 views

Products Introduction

Schmersal SLC440COM-ER-0730-35 (Order No: 103004004) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -10 ... +50 °C; Amb...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal SLC440COM-ER-0730-35, Order No: 103004004. Competitive pricing, fast quotation.

Schmersal SLC440COM-ER-0730-35 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal SLC440COM-ER-0730-35 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight2,400 g
Net weight2,400 g
Ambient temperature-10 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-10 °C
StandardsEN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661435435
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
Height of sensor771 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Bluetooth transmission frequency: 2.400 … 2.483 | Number of fail-safe digital outputs: 2 | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Designation, Control inputs: Release / restart interlock | Bluetooth transmission power, maximum: 2 | Radiation emission level to EN 12198-1: Category 0 | EPLAN: Yes | Integral system diagnostics, status: Yes | Switching voltage: 0 … 2 V (LOW) | PIN 4: Do not connect a signal (do not wire) | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Note (Software Version): as of 2024 Version 4.0 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | LED position: Emitter | PIN 2: OSSD 1 Safety output 1 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Number of beams: 25 | PIN 5: Release/restart interlock Acknowledgement restart interlock | CADENAS: Yes | Restart interlock (manual reset): Yes | TOL_VOLT_OPERAT_DC_MAX: 20 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Recommended safety switchgear: SRB-E 301 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | TOL_VOLT_OPERAT_DC_MIN: -20 | Note (applications): protective mode/automatic, restart interlock, setting mode | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Terminal connector, Recipient: Connector plug M12, 5-pole | Safety Integrity Level (SIL), suitable for applications in: 3 | Rated operating voltage: 24 | LED status: transmitting and status | Connection: Emitter | Test pulse interval, typical: 750 | Detection ability for test bodies at v = 1.6 m/s: 35 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Range, protection field, maximum: 7 | Safety type in accordance with IEC 61496-1: 4 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | PFH value: 8.05 x 10⁻⁹ | Height of the protection field: 730 | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e

More Schmersal Products from Glorient

In addition to SLC440COM-ER-0730-35, Glorient also supplies:

SHGV/ESS21S2/40/103 Order No: 101205762
SHGV/RD1/252/352+BOW Order No: 103027400
E-KB9WS/L00841111 Order No: 101218427
E-KB9.1SW/L00841009 Order No: 101218094
SLC440COM-E-1130-35-1700 Order No: 103040550
RSS16-I1-D-SK Order No: 103010516
HANDMUSTER SMS 4/5 Order No: 101209278
SVE3-Z/118/118/118-24VDC Order No: 103044493
PS116-T20-L200-N200 Order No: 103034828
AZM 415-11/02ZPKT 24VAC/DC Order No: 101186852
GEHAEUSEBODEN M.6600 D=3,2 Order No: 101157681
EF303F.1 Order No: 101022140
SSG-SB-L-200-100-100-SW-L2 Order No: 103039341
BNS 36-02/10ZG-R 5,0M Order No: 101217187
AZ/AZM201-B30-RTAG1P1-SZ Order No: 103013499
T4V7H 335-03Z-2138 Order No: 151196214
MZM 100 B ST-1P2PW2R-A Order No: 101204267
SMS 4-1080-1100-0315 Order No: 103038936
SVM1/95-10/145/E Order No: 103027293
SMS 4-936-1543-0274 Order No: 103033166
KAPPE AZ/AZM200-AS M12 4-polig Order No: 101190926
TYP.GEL. NAS 311 ST1- AS M Order No: 101181769
AV18RKX20U-GB215 Order No: 103039176
SHGV/ESS21S2/53/103 Order No: 101205775
BN 310-RZ-2327 2,0M Order No: 101148628
SHGV/B01/191+BOWR Order No: 103032344
SHGV-Z/B01/104+BO Order No: 101205379
BP 12 S Order No: 101057532

Related Guides

Typical Applications

Schmersal safety switchgear is widely used in machine guarding and process safety applications, including CNC machining centres, robotic cell fencing, packaging and bottling lines, material handling equipment, press and forming machinery, and automated assembly stations. Choosing the correct interlock or position switch with the right contact rating and coding level is essential to meeting your machine's PL or SIL requirements.

Frequently Asked Questions

Is this Schmersal product 100% genuine?

Yes. All Schmersal products we supply are 100% genuine and new in original factory packing, sourced from authorised supply channels with full factory warranty.

Does this Schmersal model have positive-break safety contacts?

Schmersal safety switches use positive-break (Zwangsöffnung) contacts designed to EN 60947-5-1, which guarantee contact separation even if the actuator is forced out or the spring fails. This is the core requirement for safety circuits rated up to PL e according to EN ISO 13849-1.

How do I get a quotation and lead time?

Send us the part number through the quote form and our team will respond within 24 hours with pricing, stock availability and estimated delivery time.

Gross weight2,400 g
Net weight2,400 g
Ambient temperature-10 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-10 °C
StandardsEN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661435435
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
Height of sensor771 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Bluetooth transmission frequency: 2.400 … 2.483 | Number of fail-safe digital outputs: 2 | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Designation, Control inputs: Release / restart interlock | Bluetooth transmission power, maximum: 2 | Radiation emission level to EN 12198-1: Category 0 | EPLAN: Yes | Integral system diagnostics, status: Yes | Switching voltage: 0 … 2 V (LOW) | PIN 4: Do not connect a signal (do not wire) | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Note (Software Version): as of 2024 Version 4.0 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | LED position: Emitter | PIN 2: OSSD 1 Safety output 1 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Number of beams: 25 | PIN 5: Release/restart interlock Acknowledgement restart interlock | CADENAS: Yes | Restart interlock (manual reset): Yes | TOL_VOLT_OPERAT_DC_MAX: 20 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Recommended safety switchgear: SRB-E 301 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | TOL_VOLT_OPERAT_DC_MIN: -20 | Note (applications): protective mode/automatic, restart interlock, setting mode | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Terminal connector, Recipient: Connector plug M12, 5-pole | Safety Integrity Level (SIL), suitable for applications in: 3 | Rated operating voltage: 24 | LED status: transmitting and status | Connection: Emitter | Test pulse interval, typical: 750 | Detection ability for test bodies at v = 1.6 m/s: 35 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Range, protection field, maximum: 7 | Safety type in accordance with IEC 61496-1: 4 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | PFH value: 8.05 x 10⁻⁹ | Height of the protection field: 730 | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e