Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

SLC445-ER-0490-14-01

Schmersal SLC445-ER-0490-14-01

Model: SLC445-ER-0490-14-01
Brand: Schmersal
Category: Safety Light Curtains
Views: 31 views

Products Introduction

Schmersal SLC445-ER-0490-14-01 (Order No: 103005390) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +50 °C; Amb...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal SLC445-ER-0490-14-01, Order No: 103005390. Competitive pricing, fast quotation.

Schmersal SLC445-ER-0490-14-01 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal SLC445-ER-0490-14-01 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight1,080 g
Net weight1,080 g
Ambient temperature-25 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-25 °C
StandardsCLC/TS 61496-2, EN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661435985
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Rated operating current: 250 | Current consumption: 0 … 2 mA (LOW) | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | PIN 11: Not used | PIN 4: COD2 Coding 2 | Beam coding available : Yes | Radiation emission level to EN 12198-1: Category 0 | Designation, Contactor controls EDM (Feedback circuits): D_IN | EPLAN: Yes | Integral system diagnostics, status: Yes | PIN 5: D_OUT Operating Mode | Actuation time for manual start: 50 … 1500 | Switching voltage: 0 … 2 V (LOW) | Height of the Sensor (Transmitter): 571 | PIN 2: 0 VDC power supply | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | Override: Yes | TOL_VOLT_OPERAT_DC_MIN: -10 | Terminal connector, Recipient: Connector plug M12, 12-pole | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Designation, Control inputs: S1, S2, MSG 1 and MSG 2 | Detection ability for test bodies at v = 1.6 m/s: 14 | Number of beams: 48 | CADENAS: Yes | Blanking function: Yes | PIN 8: Input Release S2 | Restart interlock (manual reset): Yes | Designation, Power supply: ML | ACE reference article number: 11930039 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Classification ZVEI CB24I, Source: C3 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Contactor control integrated: Yes | Designation, Safety outputs: OSSD 1 and OSSD 2 | Clock control possible : Yes | PIN 6: OSSD 2 Safety output 2 | Safety Integrity Level (SIL), suitable for applications in: 3 | LED status: OSSD ON, OSSD OFF, restart, signal reception, blanking, information | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Height of the protection field: 490 | Rated operating voltage: 24 | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Height of the Sensor (Receiver): 581 | Muting function: Yes | PIN 3: 0 VDC power supply | Note (Software Version): as of 2024 Version 1.0 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Reduced resolution : Yes | Reaction time of the external devices, maximum: 500 | Range, protection field, maximum: 7 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e

More Schmersal Products from Glorient

In addition to SLC445-ER-0490-14-01, Glorient also supplies:

G50-025M44/M44Y-5034 Order No: 101195406
SHGV/R1.1/212+BO Order No: 103003810
A-K4P-M8-S-W-2M-GY-1-X-X-4 Order No: 103011348
ZK4 236-11Z-M20-U90-1297 Order No: 151173488
AZ 17-02ZRI B5 Order No: 101136309
PS315-Z02-N301 Order No: 103035504
SHGV/B01/209+BOF/HIS.2 Order No: 103003797
PS216-T02-R200-U2 Order No: 103046681
T. 471-02/02Y-H-840 Order No: 101169156
NHS63/O.VA-PL. Order No: 101217614
TA 064-02/01Y Order No: 101060807
Z4V7H 335-11Z-ST-2138 Order No: 151173014
AZM 415-02/11XPKRS 24VAC/DC Order No: 101174583
DLH6WS/WS Order No: 101007632
PS215-Z11-M16-S200 Order No: 103033500
T. 250-11Z-T-1276-2 Order No: 101210229
BETAETIGUNGSHEBEL FORM F Order No: 101066583
SHGV/EKM38 Order No: 103007924
BNS 260-02Z-L 5,0M Order No: 101192326
SHGV/R01/217+BOW Order No: 101198304
M 6600-11-K-Y 2,0M Order No: 101055344
G50-050Z11/11Y-1601-2-1368-3 Order No: 103041199
T3K 236-11Z-M16 Order No: 151104811
SHGV/B01/127+BOW Order No: 101198395
EDTHGN Order No: 101006265
SVM1/225-10/224/E Order No: 103026043
SLB440-ER-1-ST-H-EH Order No: 103015491
VP102.1 Order No: 101209623
KEN9.1WS/HO Order No: 101024138

Related Guides

Typical Applications

Schmersal safety switchgear is widely used in machine guarding and process safety applications, including CNC machining centres, robotic cell fencing, packaging and bottling lines, material handling equipment, press and forming machinery, and automated assembly stations. Choosing the correct interlock or position switch with the right contact rating and coding level is essential to meeting your machine's PL or SIL requirements.

Frequently Asked Questions

Is this Schmersal product 100% genuine?

Yes. All Schmersal products we supply are 100% genuine and new in original factory packing, sourced from authorised supply channels with full factory warranty.

Does this Schmersal model have positive-break safety contacts?

Schmersal safety switches use positive-break (Zwangsöffnung) contacts designed to EN 60947-5-1, which guarantee contact separation even if the actuator is forced out or the spring fails. This is the core requirement for safety circuits rated up to PL e according to EN ISO 13849-1.

How do I get a quotation and lead time?

Send us the part number through the quote form and our team will respond within 24 hours with pricing, stock availability and estimated delivery time.

Gross weight1,080 g
Net weight1,080 g
Ambient temperature-25 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-25 °C
StandardsCLC/TS 61496-2, EN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661435985
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Rated operating current: 250 | Current consumption: 0 … 2 mA (LOW) | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | PIN 11: Not used | PIN 4: COD2 Coding 2 | Beam coding available : Yes | Radiation emission level to EN 12198-1: Category 0 | Designation, Contactor controls EDM (Feedback circuits): D_IN | EPLAN: Yes | Integral system diagnostics, status: Yes | PIN 5: D_OUT Operating Mode | Actuation time for manual start: 50 … 1500 | Switching voltage: 0 … 2 V (LOW) | Height of the Sensor (Transmitter): 571 | PIN 2: 0 VDC power supply | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | Override: Yes | TOL_VOLT_OPERAT_DC_MIN: -10 | Terminal connector, Recipient: Connector plug M12, 12-pole | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Designation, Control inputs: S1, S2, MSG 1 and MSG 2 | Detection ability for test bodies at v = 1.6 m/s: 14 | Number of beams: 48 | CADENAS: Yes | Blanking function: Yes | PIN 8: Input Release S2 | Restart interlock (manual reset): Yes | Designation, Power supply: ML | ACE reference article number: 11930039 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Classification ZVEI CB24I, Source: C3 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Contactor control integrated: Yes | Designation, Safety outputs: OSSD 1 and OSSD 2 | Clock control possible : Yes | PIN 6: OSSD 2 Safety output 2 | Safety Integrity Level (SIL), suitable for applications in: 3 | LED status: OSSD ON, OSSD OFF, restart, signal reception, blanking, information | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Height of the protection field: 490 | Rated operating voltage: 24 | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Height of the Sensor (Receiver): 581 | Muting function: Yes | PIN 3: 0 VDC power supply | Note (Software Version): as of 2024 Version 1.0 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Reduced resolution : Yes | Reaction time of the external devices, maximum: 500 | Range, protection field, maximum: 7 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e