Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

SLC445-ER-0890-30-01

Schmersal SLC445-ER-0890-30-01

Model: SLC445-ER-0890-30-01
Brand: Schmersal
Category: Safety Light Curtains
Views: 24 views

Products Introduction

Schmersal SLC445-ER-0890-30-01 (Order No: 103005412) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +50 °C; Amb...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal SLC445-ER-0890-30-01, Order No: 103005412. Competitive pricing, fast quotation.

Schmersal SLC445-ER-0890-30-01 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal SLC445-ER-0890-30-01 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight1,680 g
Net weight1,680 g
Ambient temperature-25 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-25 °C
StandardsCLC/TS 61496-2, EN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661436265
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Rated operating current: 250 | Current consumption: 0 … 2 mA (LOW) | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | PIN 11: Not used | PIN 4: COD2 Coding 2 | Beam coding available : Yes | Radiation emission level to EN 12198-1: Category 0 | Designation, Contactor controls EDM (Feedback circuits): D_IN | EPLAN: Yes | ACE reference article number: 11930069 | Integral system diagnostics, status: Yes | PIN 5: D_OUT Operating Mode | Actuation time for manual start: 50 … 1500 | Switching voltage: 0 … 2 V (LOW) | PIN 2: 0 VDC power supply | Tolerance, percentage: 10 | Height of the Sensor (Transmitter): 971 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | Override: Yes | TOL_VOLT_OPERAT_DC_MIN: -10 | Terminal connector, Recipient: Connector plug M12, 12-pole | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Designation, Control inputs: S1, S2, MSG 1 and MSG 2 | CADENAS: Yes | Blanking function: Yes | PIN 8: Input Release S2 | Restart interlock (manual reset): Yes | Designation, Power supply: ML | Range, protection field, maximum: 10 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Classification ZVEI CB24I, Source: C3 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Contactor control integrated: Yes | Height of the Sensor (Receiver): 981 | Designation, Safety outputs: OSSD 1 and OSSD 2 | Clock control possible : Yes | PIN 6: OSSD 2 Safety output 2 | Safety Integrity Level (SIL), suitable for applications in: 3 | LED status: OSSD ON, OSSD OFF, restart, signal reception, blanking, information | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Rated operating voltage: 24 | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Muting function: Yes | PIN 3: 0 VDC power supply | Note (Software Version): as of 2024 Version 1.0 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Reduced resolution : Yes | Reaction time of the external devices, maximum: 500 | Detection ability for test bodies at v = 1.6 m/s: 30 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e | Number of beams: 44 | Height of the protection field: 890

More Schmersal Products from Glorient

In addition to SLC445-ER-0890-30-01, Glorient also supplies:

SHGV/R01/64+BO Order No: 103013203
T4V10H 336-11Z-U90 Order No: 151084621
SVE2/111/111-3Ö-24VDC Order No: 101197646
E-KB9WS/L00841187 Order No: 101218486
PS316-Z12-K360 Order No: 103015136
RSS16-I2-D-R-SK Order No: 103010485
SLC440COM-ER-0890-14 Order No: 103003902
TR 335-03Z Order No: 151147369
TR 335-11Z-ST-2467 Order No: 101178075
T. 250-11Z-1172-1276-2-2087 Order No: 101212582
T4V7H 336-02X-M20-1897/1637 Order No: 151162634
PS-K200 Order No: 103010961
SHGV/RD1/106/56+BO Order No: 103001244
T4VH 336-11YR-1058 Order No: 151142571
SSG-SK1.2 Order No: 103008115
SLC440COM-ER-0650-35-1700 Order No: 103040532
STW-SL-N-06-3100-2-L5 Order No: 103047425
EX-AZM300Z-I2-ST-1P2P-A-CR-3GD Order No: 103052212
AZM 170-11ZRI-B6R 24VAC/DC Order No: 101140805
SHGV/EKM201 Order No: 103008161
TV15H 236-02Z-M16 Order No: 151208265
PS116-Z11-LR200-R200 Order No: 103006565
T1K 336-20Z Order No: 101102907
EX-ZR 235-11Z-3D Order No: 101189789
BNS 180-11Z 10,0M Order No: 101149430
AZ 15 ZVRK-M20-1637 Order No: 101173064

Related Guides

Typical Applications

Schmersal safety switchgear is widely used in machine guarding and process safety applications, including CNC machining centres, robotic cell fencing, packaging and bottling lines, material handling equipment, press and forming machinery, and automated assembly stations. Choosing the correct interlock or position switch with the right contact rating and coding level is essential to meeting your machine's PL or SIL requirements.

Frequently Asked Questions

Is this Schmersal product 100% genuine?

Yes. All Schmersal products we supply are 100% genuine and new in original factory packing, sourced from authorised supply channels with full factory warranty.

Does this Schmersal model have positive-break safety contacts?

Schmersal safety switches use positive-break (Zwangsöffnung) contacts designed to EN 60947-5-1, which guarantee contact separation even if the actuator is forced out or the spring fails. This is the core requirement for safety circuits rated up to PL e according to EN ISO 13849-1.

How do I get a quotation and lead time?

Send us the part number through the quote form and our team will respond within 24 hours with pricing, stock availability and estimated delivery time.

Gross weight1,680 g
Net weight1,680 g
Ambient temperature-25 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-25 °C
StandardsCLC/TS 61496-2, EN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661436265
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Rated operating current: 250 | Current consumption: 0 … 2 mA (LOW) | Length of the connectable cable, maximum: 100 | Range, protection field, minimum: 0.3 | PIN 11: Not used | PIN 4: COD2 Coding 2 | Beam coding available : Yes | Radiation emission level to EN 12198-1: Category 0 | Designation, Contactor controls EDM (Feedback circuits): D_IN | EPLAN: Yes | ACE reference article number: 11930069 | Integral system diagnostics, status: Yes | PIN 5: D_OUT Operating Mode | Actuation time for manual start: 50 … 1500 | Switching voltage: 0 … 2 V (LOW) | PIN 2: 0 VDC power supply | Tolerance, percentage: 10 | Height of the Sensor (Transmitter): 971 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | Override: Yes | TOL_VOLT_OPERAT_DC_MIN: -10 | Terminal connector, Recipient: Connector plug M12, 12-pole | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Designation, Control inputs: S1, S2, MSG 1 and MSG 2 | CADENAS: Yes | Blanking function: Yes | PIN 8: Input Release S2 | Restart interlock (manual reset): Yes | Designation, Power supply: ML | Range, protection field, maximum: 10 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Classification ZVEI CB24I, Source: C3 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Contactor control integrated: Yes | Height of the Sensor (Receiver): 981 | Designation, Safety outputs: OSSD 1 and OSSD 2 | Clock control possible : Yes | PIN 6: OSSD 2 Safety output 2 | Safety Integrity Level (SIL), suitable for applications in: 3 | LED status: OSSD ON, OSSD OFF, restart, signal reception, blanking, information | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Rated operating voltage: 24 | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Muting function: Yes | PIN 3: 0 VDC power supply | Note (Software Version): as of 2024 Version 1.0 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Reduced resolution : Yes | Reaction time of the external devices, maximum: 500 | Detection ability for test bodies at v = 1.6 m/s: 30 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e | Number of beams: 44 | Height of the protection field: 890