Schmersal SLG445-ER-0500-02-01 (Order No: 103005424) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +50 °C; Amb...
Glorient offers competitive supply of Schmersal SLG445-ER-0500-02-01, Order No: 103005424. Competitive pricing, fast quotation.
Schmersal SLG445-ER-0500-02-01 - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal SLG445-ER-0500-02-01 is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 980 g |
| Net weight | 980 g |
| Ambient temperature | -25 ... +50 °C |
| Ambient temperature, maximum | 1000079357 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661436388 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Reaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Rated operating current: 250 | Current consumption: 0 … 2 mA (LOW) | Range, protection field, minimum: 0.3 | PIN 11: Not used | PIN 4: COD2 Coding 2 | Beam coding available : Yes | Radiation emission level to EN 12198-1: Category 0 | Designation, Contactor controls EDM (Feedback circuits): D_IN | EPLAN: Yes | Height of the Sensor (Receiver): 621 | Integral system diagnostics, status: Yes | PIN 5: D_OUT Operating Mode | Actuation time for manual start: 50 … 1500 | Switching voltage: 0 … 2 V (LOW) | PIN 2: 0 VDC power supply | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | Override: Yes | TOL_VOLT_OPERAT_DC_MIN: -10 | Terminal connector, Recipient: Connector plug M12, 12-pole | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Designation, Control inputs: S1, S2, MSG 1 and MSG 2 | CADENAS: Yes | PIN 8: Input Release S2 | Restart interlock (manual reset): Yes | Designation, Power supply: ML | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Classification ZVEI CB24I, Source: C3 | Length of cable: 100 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Range, protection field, maximum: 12 | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Height of the protection field: 500 | Designation, Safety outputs: OSSD 1 and OSSD 2 | Number of beams: 2 | Clock control possible : Yes | PIN 6: OSSD 2 Safety output 2 | Safety Integrity Level (SIL), suitable for applications in: 3 | LED status: OSSD ON, OSSD OFF, restart, signal reception, blanking, information | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Length of cable, maximum: 100 | Rated operating voltage: 24 | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Muting function: Yes | PIN 3: 0 VDC power supply | ACE reference article number: 11930052 | Note (Software Version): as of 2024 Version 1.0 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Reaction time of the external devices, maximum: 500 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Detection ability for test bodies at v = 1.6 m/s: 500 | Output current, (fail-safe output), maximum: 0.25 | Height of the Sensor (Transmitter): 611 | Performance Level, up to: e |
In addition to SLG445-ER-0500-02-01, Glorient also supplies:
| Gross weight | 980 g |
| Net weight | 980 g |
| Ambient temperature | -25 ... +50 °C |
| Ambient temperature, maximum | 1000079357 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 61496-1 |
| IP Degree of protection | IP67 |
| Certificates | cULus |
| Housing material | Aluminium |
| EAN (European Article Number) | 4030661436388 |
| Mission time | 20 |
| Termination | Connector |
| Length of sensor | 33 mm |
| Width of sensor | 27.8 mm |
| Note | In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
| Traceparts | Yes |
| Resistance to vibrations | 10 … 55 Hz |
| Storage and transport temperature | -25 ... +70 °C |
| Scope of delivery | Kit with 2 mounting angles |
| Storage and transport temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Protection class | III |
| Other Parameters | Reaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Rated operating current: 250 | Current consumption: 0 … 2 mA (LOW) | Range, protection field, minimum: 0.3 | PIN 11: Not used | PIN 4: COD2 Coding 2 | Beam coding available : Yes | Radiation emission level to EN 12198-1: Category 0 | Designation, Contactor controls EDM (Feedback circuits): D_IN | EPLAN: Yes | Height of the Sensor (Receiver): 621 | Integral system diagnostics, status: Yes | PIN 5: D_OUT Operating Mode | Actuation time for manual start: 50 … 1500 | Switching voltage: 0 … 2 V (LOW) | PIN 2: 0 VDC power supply | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Switching thresholds: 11 … 30 V (HIGH) | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | 7-segment display: Yes | LED position: Emitter | Override: Yes | TOL_VOLT_OPERAT_DC_MIN: -10 | Terminal connector, Recipient: Connector plug M12, 12-pole | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | Designation, Control inputs: S1, S2, MSG 1 and MSG 2 | CADENAS: Yes | PIN 8: Input Release S2 | Restart interlock (manual reset): Yes | Designation, Power supply: ML | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Classification ZVEI CB24I, Source: C3 | Length of cable: 100 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Range, protection field, maximum: 12 | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Height of the protection field: 500 | Designation, Safety outputs: OSSD 1 and OSSD 2 | Number of beams: 2 | Clock control possible : Yes | PIN 6: OSSD 2 Safety output 2 | Safety Integrity Level (SIL), suitable for applications in: 3 | LED status: OSSD ON, OSSD OFF, restart, signal reception, blanking, information | PFH value: 5.14 x 10⁻⁹ | Load capacity, maximum: 2.2 | Length of cable, maximum: 100 | Rated operating voltage: 24 | Connection: Emitter | Test pulse duration, maximum: 0.1 | Test pulse interval, typical: 750 | Muting function: Yes | PIN 3: 0 VDC power supply | ACE reference article number: 11930052 | Note (Software Version): as of 2024 Version 1.0 | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Reaction time of the external devices, maximum: 500 | Conduction resistance, maximum: 2.5 | Safety type in accordance with IEC 61496-1: 4 | Terminal (mechanical): with metal thread | Wave length of the laserdiode: 880 | Detection ability for test bodies at v = 1.6 m/s: 500 | Output current, (fail-safe output), maximum: 0.25 | Height of the Sensor (Transmitter): 611 | Performance Level, up to: e |