Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM400Z-ST2-I2-2P2P-T-E

Schmersal AZM400Z-ST2-I2-2P2P-T-E

Model: AZM400Z-ST2-I2-2P2P-T-E
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 16 views

Products Introduction

Schmersal AZM400Z-ST2-I2-2P2P-T-E (Order No: 103003836) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -20 ... +55 °C; ...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM400Z-ST2-I2-2P2P-T-E, Order No: 103003836. Competitive pricing, fast quotation.

Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.

More Schmersal Products from Glorient

In addition to AZM400Z-ST2-I2-2P2P-T-E, Glorient also supplies:

SVM1/102-6/117/E Order No: 103000983
AZ/AZM 200-B30-RTAG2P25 Order No: 101192104
EX-AZ3350-B5 Order No: 101214012
AZM201BZ-ST-T-AS-P Order No: 103025873
PS116-Z11-ST-J200 Order No: 103032704
ZK4 236-11Z-M20-1297 Order No: 151165222
AZM 415-11/11ZPKT 24VAC/DC Order No: 101167201
E-KB9.1SW/L00841295 Order No: 101218160
SMS 5-610-1130-0263 Order No: 103032944
ZAF 256-11Z Order No: 153004135
SMS 4-520-1465 Order No: 103034816
G150-150M22/22Y-1600-1 Order No: 101174106
EDRR-2.1/RAL1012 Order No: 101024273
SLC440AS-E-1290-30 Order No: 103007525
Z1K 335-11Z-1637 Order No: 151149541
SLC440-ER-0170-14-01-1500 Order No: 103006456
SLG445-ER-0500-02-01 Order No: 103005424
MZM 100 ST2-1P2P-A Order No: 101199622
DICHTUNG BG-130 Order No: 101000457
WKTC52/WKT-19.3 Order No: 101193043
NDLBL/516D Order No: 103000956
SCHNORR-SCHEIBE GR.16 FE Order No: 101084518
STW-SL-N-08-1860-1-L10 Order No: 103045317
SHGV/LD1/216/37+BOW Order No: 101198543
SHGV/ESS21S2/264/103 Order No: 103048707
AV15RKX20U-1453 Order No: 103042196
ESS21S1/EKM154 Order No: 103050288
AZ 16-12ZIB1-M16-2024 Order No: 101150052

Related Guides

Gross weight774 g
Net weight774 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatescULus
Housing materialLight alloy die-casting
EAN (European Article Number)4030661472683
Mission time20
Termination2 connector M12, 8 and 5 pin., both A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor65.3 mm
Width of sensor77.8 mm
Height of sensor156.7 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
NoteThe diagnostic output are not safety relevant outputs!
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-40 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Degree of pollution3
Protection classIII
Other ParametersCoding: Individual coding, multiple teaching | PIN 3: A2 GND | Number of fail-safe digital outputs: 2 | Current consumption at 24V, maximum: 10 | Switching thresholds of the control inputs: 15 V … 30 V (High) | Note (LED switching conditions display): Error / functional defect: LED red | PFH value: 1.00 x 10⁻⁹ | Time to readiness, maximum: 1,500 | Connection: Connector 2 | Design of control elements: short-circuit proof, p-type | Interlocking principle: bistable | Electronic manual release: Yes | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Lateral force at bolt return, maximal (against locked door): 300 | Minimal average cycle time (with continuous operation): 20 | PFD value: 9.00 x 10⁻⁵ | Note (Mechanical lifetime): Which have a lateral force Ftrans = 100 N: 100.000 operations | Allowed distance interlock to actuator, minimum: 1 | Cross-circuit detection: Yes | PIN 6: E3 Control input 3 | REVIEW_ELEC_WIRING_GENERAL_GPV: 2 connector M12, 8 and 5 pin., both A-coded | Rated operating voltage: 24 VDC | Voltage, Utilisation category DC-12: 24 | Category: 4 | Auxiliary power supply Uhe: 24 VDC -15 % / +10 % (UPS / uninterruptable power supply) | Classification ZVEI CB24I, Source: C1 | Performance Level, up to: e | Restistance to shock: 30 g / 11 ms | PIN 1: A1 Supply voltage UB | PIN 2: H2 GND | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 8: E2 Control input 2 | Relative humidity, maximum: 93 | Emergency exit: Yes | External wire and device fuse rating: 2 A gG | Note (Type of the fixing screws): Property class min. 10.9 | Safety Integrity Level (SIL), suitable for applications in: 3 | Minimum distance devices: 30 | PIN 4: H1 Auxiliary voltage Uhe | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | CADENAS: Yes | Utilisation category DC-12: 24 VDC / 0.25 A | Operating current while bolt movement, peak: 600 mA / 100 ms | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Permissible residual drive current: 1.5 | Classification ZVEI CB24I, Sink: C1 | Test pulse duration, maximum: 5 | Recommendation (actuator): AZM400-B1 | Designation, Control inputs: E1 und E2 (p-schaltend), E3 (n-schaltend) | TOL_VOLT_OPERAT_DC_MAX: 10 | Allowable discrepancy time (input), maximum: 10 | Allowed distance interlock to actuator, maximum: 7 | Reaction time, switching off safety outputs via actuator, maximum: 100 | Designation, Diagnostic outputs: OUT1 / OUT2 | Frequency band RFID: 125 | ACE reference article number: 11930333 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Note (Lateral force at bolt return): Does not apply to emergency exit, Bowden cable and manual release | Switching frequency, maximum: 0.3 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Number of diagnostic signals: 2 | PIN 5: OUT1 Diagnostic output 1 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Current consumption at 24V, minimum: 5 | Test pulse interval, typical: 1,000 | Electrical fuse rating, maximum: 2 | Open / close cycle (motor), minimum: 3 | Tightening torque of the screw: 8 | Designation, Safety outputs: Y1 and Y2 | Test pulse interval, maximum: 40