SLG240COM-ER-0800-03

Schmersal SLG240COM-ER-0800-03

Model: SLG240COM-ER-0800-03
Brand: Schmersal
Category: Safety Light Curtains
Views: 24 views

Products Introduction

Schmersal SLG240COM-ER-0800-03 (Order No: 103016122) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -10 ... +50 °C; Amb...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal SLG240COM-ER-0800-03, Order No: 103016122. Competitive pricing, fast quotation.

Schmersal SLG240COM-ER-0800-03 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal SLG240COM-ER-0800-03 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight1,440 g
Net weight1,440 g
Ambient temperature-10 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-10 °C
StandardsEN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661506517
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
Height of sensor871 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Category: 2 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Radiation emission level to EN 12198-1: Category 0 | PIN 4: Slave Series wiring | Designation, Control inputs: Reset and Test | Integral system diagnostics, status: Yes | Switching voltage: 0 … 2 V (LOW) | PIN 5: Reset Restart interlock (manual reset) | Tolerance, percentage: 10 | PIN 2: Test Test input | Rated operating current, Emitter: 200 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | Switching thresholds: 24 V (HIGH) | TOL_VOLT_OPERAT_DC_MIN: -10 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | LED position: Receiver | Load inductance, maximum: 2 | Safety Integrity Level (SIL), suitable for applications in: 1 | CADENAS: Yes | Blanking function: Yes | Height of the protection field: 800 | Restart interlock (manual reset): Yes | Classification ZVEI CB24I, Sink: C1 | Length of cable: 100 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Range, protection field, maximum: 12 | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Detection ability for test bodies at v = 1.6 m/s: 400 | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Number of beams: 3 | Cascadable: Yes | Safety type in accordance with IEC 61496-1: 2 | Terminal connector, Recipient: Connector plug M12, 5-pole | Performance Level, up to: c | Rated operating voltage: 24 | Connection: Emitter | Test pulse interval, typical: 750 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Note (Software Version): as of 2017 Version 1.0 | Master- or Slave-function: Yes | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | LED status: OSSD ON, OSSD OFF, Restart interlock, Error, Parameter setting, Alignment kit, Indication of signal quality | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25

More Schmersal Products from Glorient

In addition to SLG240COM-ER-0800-03, Glorient also supplies:

BNS 260-11Z-R 2,0M Order No: 101190978
CSS-Y-A-8P Order No: 101209414
SHGV/L1.1/115+BO Order No: 101216498
ACC-IL-G24-M20-OR Order No: 101186263
SHGV/LD1/113/47+BO Order No: 103003003
SHGV/RD1/110/40+BOW Order No: 103013455
PS116-Z12-L200-N200 Order No: 103008748
TV7H 235-02Z-2138 Order No: 151165660
E-KB9.1SW/L00841493 Order No: 101218252
ZR 336-02Z-ST Order No: 151177696
T4V7H 336-02YR-1058/2138 Order No: 151194174
BDF-U200-PBC-LT-GN Order No: 103016004
HEBEL KPL. H92 SPEZ 1402 Order No: 101137088
T3Z 068-22YR-1172-1637 Order No: 131205564
MZM 100 ST-1P2PWM-A Order No: 101209061
RDTWS/912 Order No: 103010614
RSS 36-I1-ST-AS Order No: 103001536
SSG-SB-L-200-100-100-SW-L2 Order No: 103039341
MZM 100 ST2-1P2PR-A Order No: 101210074
SLC440-ER-1370-30 Order No: 101216728
AZM 415-11/11ZPKE 110VAC Order No: 101167191
EX-BNS 250-12Z-2187-3GD 25M Order No: 103045526
ZV7H 235-11Z-M20 Order No: 151168066
NDTGN/101D Order No: 101189520
SHGV/D1.1/160+BOW Order No: 103013205
PS-K201 Order No: 103051280
SHGV/EKM169 Order No: 103035025
SMS 5-1000-1600-0251 Order No: 103027028
ELK Order No: 101022278
SICHERUNGSHUELSE Z-142 Order No: 101160826

Related Guides

Gross weight1,440 g
Net weight1,440 g
Ambient temperature-10 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-10 °C
StandardsEN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661506517
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
Height of sensor871 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Number of fail-safe digital outputs: 2 | Category: 2 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Radiation emission level to EN 12198-1: Category 0 | PIN 4: Slave Series wiring | Designation, Control inputs: Reset and Test | Integral system diagnostics, status: Yes | Switching voltage: 0 … 2 V (LOW) | PIN 5: Reset Restart interlock (manual reset) | Tolerance, percentage: 10 | PIN 2: Test Test input | Rated operating current, Emitter: 200 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | Switching thresholds: 24 V (HIGH) | TOL_VOLT_OPERAT_DC_MIN: -10 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | LED position: Receiver | Load inductance, maximum: 2 | Safety Integrity Level (SIL), suitable for applications in: 1 | CADENAS: Yes | Blanking function: Yes | Height of the protection field: 800 | Restart interlock (manual reset): Yes | Classification ZVEI CB24I, Sink: C1 | Length of cable: 100 | Recommended safety switchgear: SRB-E 301 | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 1: 24 VDC power supply | Range, protection field, maximum: 12 | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Detection ability for test bodies at v = 1.6 m/s: 400 | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Number of beams: 3 | Cascadable: Yes | Safety type in accordance with IEC 61496-1: 2 | Terminal connector, Recipient: Connector plug M12, 5-pole | Performance Level, up to: c | Rated operating voltage: 24 | Connection: Emitter | Test pulse interval, typical: 750 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Note (Software Version): as of 2017 Version 1.0 | Master- or Slave-function: Yes | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | LED status: OSSD ON, OSSD OFF, Restart interlock, Error, Parameter setting, Alignment kit, Indication of signal quality | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25