Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

AZM400Z-ST2-I2-2P2P-BOW-E

Schmersal AZM400Z-ST2-I2-2P2P-BOW-E

Model: AZM400Z-ST2-I2-2P2P-BOW-E
Brand: Schmersal
Category: Solenoid Safety Locks
Views: 18 views

Products Introduction

Schmersal AZM400Z-ST2-I2-2P2P-BOW-E (Order No: 103015313) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -20 ... +55 °C...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal AZM400Z-ST2-I2-2P2P-BOW-E, Order No: 103015313. Competitive pricing, fast quotation.

Schmersal AZM400Z-ST2-I2-2P2P-BOW-E - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal AZM400Z-ST2-I2-2P2P-BOW-E is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight859 g
Net weight859 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatescULus
Housing materialLight alloy die-casting
EAN (European Article Number)4030661503981
Mission time20
Termination2 connector M12, 8 and 5 pin., both A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor46.7 mm
Width of sensor77.8 mm
Height of sensor156.7 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
NoteProtection class remains with correctly installed bowden cable release
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-40 ... +85 °C
Scope of deliveryThe actuator and the Bowden cable are not included in delivery.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Degree of pollution3
Protection classIII
Other ParametersCoding: Individual coding, multiple teaching | PIN 3: A2 GND | Number of fail-safe digital outputs: 2 | Current consumption at 24V, maximum: 10 | Switching thresholds of the control inputs: 15 V … 30 V (High) | Note (LED switching conditions display): Error / functional defect: LED red | PFH value: 1.00 x 10⁻⁹ | Time to readiness, maximum: 1,500 | Connection: Connector 2 | Design of control elements: short-circuit proof, p-type | Interlocking principle: bistable | Electronic manual release: Yes | Note (Relative humidity): non-condensing | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Lateral force at bolt return, maximal (against locked door): 300 | Minimal average cycle time (with continuous operation): 20 | PFD value: 9.00 x 10⁻⁵ | Note (Mechanical lifetime): Which have a lateral force Ftrans = 100 N: 100.000 operations | Allowed distance interlock to actuator, minimum: 1 | Cross-circuit detection: Yes | PIN 6: E3 Control input 3 | Rated operating voltage: 24 VDC | Voltage, Utilisation category DC-12: 24 | Category: 4 | Auxiliary power supply Uhe: 24 VDC -15 % / +10 % (UPS / uninterruptable power supply) | Classification ZVEI CB24I, Source: C1 | Performance Level, up to: e | Restistance to shock: 30 g / 11 ms | PIN 1: A1 Supply voltage UB | PIN 2: H2 GND | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 8: E2 Control input 2 | Relative humidity, maximum: 93 | External wire and device fuse rating: 2 A gG | Note (Type of the fixing screws): Property class min. 10.9 | REVIEW_ELEC_WIRING_GENERAL_GPV: 2 connector M12, 8 and 5 pin., both A-coded | Safety Integrity Level (SIL), suitable for applications in: 3 | Minimum distance devices: 30 | PIN 4: H1 Auxiliary voltage Uhe | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | CADENAS: Yes | Utilisation category DC-12: 24 VDC / 0.25 A | Operating current while bolt movement, peak: 600 mA / 100 ms | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Permissible residual drive current: 1.5 | Classification ZVEI CB24I, Sink: C1 | Test pulse duration, maximum: 5 | Recommendation (actuator): AZM400-B1 | Designation, Control inputs: E1 und E2 (p-schaltend), E3 (n-schaltend) | TOL_VOLT_OPERAT_DC_MAX: 10 | Allowable discrepancy time (input), maximum: 10 | Allowed distance interlock to actuator, maximum: 7 | Reaction time, switching off safety outputs via actuator, maximum: 100 | Traceparts, product ID: 69-26052015-108616 | Designation, Diagnostic outputs: OUT1 / OUT2 | Tightening torque of the fixing screws Bowden cable: 1.2 | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Note (Lateral force at bolt return): Does not apply to emergency exit, Bowden cable and manual release | Switching frequency, maximum: 0.3 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Number of diagnostic signals: 2 | PIN 5: OUT1 Diagnostic output 1 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Current consumption at 24V, minimum: 5 | Test pulse interval, typical: 1,000 | Electrical fuse rating, maximum: 2 | Securing holes for Bowden cable assembly: Yes | Open / close cycle (motor), minimum: 3 | Tightening torque of the screw: 8 | Designation, Safety outputs: Y1 and Y2 | Test pulse interval, maximum: 40

More Schmersal Products from Glorient

In addition to AZM400Z-ST2-I2-2P2P-BOW-E, Glorient also supplies:

SSW303HV Order No: 103034847
SHGV/LD1/100/53+BOF/HIS.1 Order No: 103050957
SLC240COM-ER-0730-30 Order No: 103016163
NDTWS/503D Order No: 101189572
MKTE52/2X401-2949-1 Order No: 103016111
EBP33.1/E.V. Order No: 103001468
ACC-RSS260-SK Order No: 103004733
AV20RHX30U-GB215 Order No: 101174506
Z4V1H 335-11Z-G24 Order No: 151122574
SHGV/B01/123+BOW Order No: 101198391
AZM150SK-11/02RIA-024-B6R Order No: 153032230
AZM 170-02ZRI-ST-B6L 24VAC/DC Order No: 101144373
SHGV/LD1/219/40+BOW Order No: 103047913
BDF200-NHK-11-LTWH-B-LTBU Order No: 103003378
AZM400Z-ST-1P2P-BOW Order No: 103015314
BP 12 N Order No: 101059917
BN 650-10Z/V 3,0M Order No: 103000634
BP 31 N Order No: 101057520
TK 016-03Y-H-2322 Order No: 131148062
AZ 16-12ZVRK-M20 Order No: 101157373
AZ 14-1 KD KONTAKT Order No: 101157699
SHGV/RD1/100/40+BOW Order No: 103010293
PS216-Z02-N206 Order No: 103051804
SVE1-Z/128-24VDC Order No: 103044483
PS216-T01K-K210 Order No: 103042839
EX-RZSO/V4A Order No: 101205151
M 630-01-2-C-1298 Order No: 101062437
EDLGB/D2137 Order No: 101187416

Related Guides

Gross weight859 g
Net weight859 g
Ambient temperature-20 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-20 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP66
CertificatescULus
Housing materialLight alloy die-casting
EAN (European Article Number)4030661503981
Mission time20
Termination2 connector M12, 8 and 5 pin., both A-coded
Mechanical lifetime, minimum1,000,000
Length of sensor46.7 mm
Width of sensor77.8 mm
Height of sensor156.7 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
NoteProtection class remains with correctly installed bowden cable release
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm
Storage and transport temperature-40 ... +85 °C
Scope of deliveryThe actuator and the Bowden cable are not included in delivery.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
Degree of pollution3
Protection classIII
Other ParametersCoding: Individual coding, multiple teaching | PIN 3: A2 GND | Number of fail-safe digital outputs: 2 | Current consumption at 24V, maximum: 10 | Switching thresholds of the control inputs: 15 V … 30 V (High) | Note (LED switching conditions display): Error / functional defect: LED red | PFH value: 1.00 x 10⁻⁹ | Time to readiness, maximum: 1,500 | Connection: Connector 2 | Design of control elements: short-circuit proof, p-type | Interlocking principle: bistable | Electronic manual release: Yes | Note (Relative humidity): non-condensing | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Lateral force at bolt return, maximal (against locked door): 300 | Minimal average cycle time (with continuous operation): 20 | PFD value: 9.00 x 10⁻⁵ | Note (Mechanical lifetime): Which have a lateral force Ftrans = 100 N: 100.000 operations | Allowed distance interlock to actuator, minimum: 1 | Cross-circuit detection: Yes | PIN 6: E3 Control input 3 | Rated operating voltage: 24 VDC | Voltage, Utilisation category DC-12: 24 | Category: 4 | Auxiliary power supply Uhe: 24 VDC -15 % / +10 % (UPS / uninterruptable power supply) | Classification ZVEI CB24I, Source: C1 | Performance Level, up to: e | Restistance to shock: 30 g / 11 ms | PIN 1: A1 Supply voltage UB | PIN 2: H2 GND | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | PIN 8: E2 Control input 2 | Relative humidity, maximum: 93 | External wire and device fuse rating: 2 A gG | Note (Type of the fixing screws): Property class min. 10.9 | REVIEW_ELEC_WIRING_GENERAL_GPV: 2 connector M12, 8 and 5 pin., both A-coded | Safety Integrity Level (SIL), suitable for applications in: 3 | Minimum distance devices: 30 | PIN 4: H1 Auxiliary voltage Uhe | Working principle: RFID | Transmitter output RFID, maximum: -6 | Type of the fixing screws: 2x M6 | CADENAS: Yes | Utilisation category DC-12: 24 VDC / 0.25 A | Operating current while bolt movement, peak: 600 mA / 100 ms | Current, Utilisation category DC-12: 0.05 | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Permissible residual drive current: 1.5 | Classification ZVEI CB24I, Sink: C1 | Test pulse duration, maximum: 5 | Recommendation (actuator): AZM400-B1 | Designation, Control inputs: E1 und E2 (p-schaltend), E3 (n-schaltend) | TOL_VOLT_OPERAT_DC_MAX: 10 | Allowable discrepancy time (input), maximum: 10 | Allowed distance interlock to actuator, maximum: 7 | Reaction time, switching off safety outputs via actuator, maximum: 100 | Traceparts, product ID: 69-26052015-108616 | Designation, Diagnostic outputs: OUT1 / OUT2 | Tightening torque of the fixing screws Bowden cable: 1.2 | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Note (Lateral force at bolt return): Does not apply to emergency exit, Bowden cable and manual release | Switching frequency, maximum: 0.3 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Number of diagnostic signals: 2 | PIN 5: OUT1 Diagnostic output 1 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Current consumption at 24V, minimum: 5 | Test pulse interval, typical: 1,000 | Electrical fuse rating, maximum: 2 | Securing holes for Bowden cable assembly: Yes | Open / close cycle (motor), minimum: 3 | Tightening torque of the screw: 8 | Designation, Safety outputs: Y1 and Y2 | Test pulse interval, maximum: 40