Schmersal AZM40Z-I2-ST-1P2P-PH (Order No: 103037335) is a genuine solenoid safety locks engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: mounting holes plain; Ambient ...
Glorient offers competitive supply of Schmersal AZM40Z-I2-ST-1P2P-PH, Order No: 103037335. Competitive pricing, fast quotation.
Schmersal AZM40Z-I2-ST-1P2P-PH - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal AZM40Z-I2-ST-1P2P-PH is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 303 g |
| Net weight | 303 g |
| Ambient temperature | -20 ... +55 °C |
| Ambient temperature, maximum | +55 °C |
| Ambient temperature, minimum | -20 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP66 |
| Certificates | TÜV, cULus, FCC, IC, UKCA, ANATEL |
| Housing material | Light alloy die cast and plastic (glass-fibre reinforced thermoplastic) |
| EAN (European Article Number) | 4030661543758 |
| Mission time | 20 |
| Length of sensor | 119.5 mm |
| Width of sensor | 40 mm |
| Height of sensor | 20 mm |
| Utilisation category DC-13 | 24 VDC / 0.25 A |
| Required rated short-circuit current | 100 A |
| Actuating speed, maximum | 0.5 m/s |
| Note | Observe the maximum tightening torque of the fixing screws used. |
| Traceparts | Yes |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -40 ... +85 °C |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -40 °C |
| Mounting | mounting holes plain |
| Degree of pollution | 3 |
| Protection class | III |
| Other Parameters | Operating current: 1,200 | Coding: Individual coding, multiple teaching | Mechanical lifetime, actuator cycles: 500,000 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Rated operating voltage: 24 VDC - 15 % / + 10 % (stabilised PELV) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Category: 2 | Test pulse duration, maximum: 5 | Note (Manual release): Manual release from side | Interlocking principle: bistable | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Property class: 8.8 / 80 | Integral system diagnostics, status: Yes | Recommendation (actuator): AZM40-B1-PH | Current consumption at 24V, maximum: 15 | Mechanical lifetime, locking cycles: 1,000,000 | Note (Mechanical lifetime): from device version V2 (V1 = 200.000 actuator cycles) | ACE reference article number: 11931065 | Series-wiring: Yes | Cross-circuit detection: Yes | Installation conditions (mechanical): arbitrarily | PFH value: 3.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Current consumption at 24 V: 10 ... 15 mA | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | External wire and device fuse rating: 2 A gG | Design of control elements: OSSD, short-circuit proof, p-type | Classification ZVEI CB24I, Sink: C1 | PFD value: 8.90 x 10⁻⁵ | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Working principle: RFID | Transmitter output RFID, maximum: -6 | CADENAS: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Tightening torque of the fixing screws: 4 ... 6 Nm | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Safety Integrity Level (SIL), suitable for applications in: 2 | Current, Utilisation category DC-13: 0.05 | Switching frequency, maximum: 0.25 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | REVIEW_ELEC_WIRING_GENERAL_GPV: 1000390331 | Tightening torque of the fixing screws, maximum: 6 | Current consumption magnet at switching moment, peak: 600 mA / 100 ms | TOL_VOLT_OPERAT_DC_MAX: 10 | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Unlocking: Rotating unlatcher | Duration of risk, maximum: 200 | Performance Level, up to: e | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Current consumption at 24V, minimum: 10 | TOL_VOLT_OPERAT_DC_MIN: -15 | Latching force: 40 N | Manual release: Yes | Actuating angle: 180 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Note (Latch force): +/- 25% | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Designation, Safety outputs: Y1 and Y2 | Tightening torque of the fixing screws, minimum: 4 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Type of the fixing screws: 2x M5 |
In addition to AZM40Z-I2-ST-1P2P-PH, Glorient also supplies:
| Gross weight | 303 g |
| Net weight | 303 g |
| Ambient temperature | -20 ... +55 °C |
| Ambient temperature, maximum | +55 °C |
| Ambient temperature, minimum | -20 °C |
| Standards | EN IEC 60947-5-3 |
| IP Degree of protection | IP66 |
| Certificates | TÜV, cULus, FCC, IC, UKCA, ANATEL |
| Housing material | Light alloy die cast and plastic (glass-fibre reinforced thermoplastic) |
| EAN (European Article Number) | 4030661543758 |
| Mission time | 20 |
| Length of sensor | 119.5 mm |
| Width of sensor | 40 mm |
| Height of sensor | 20 mm |
| Utilisation category DC-13 | 24 VDC / 0.25 A |
| Required rated short-circuit current | 100 A |
| Actuating speed, maximum | 0.5 m/s |
| Note | Observe the maximum tightening torque of the fixing screws used. |
| Traceparts | Yes |
| Safety functions | Yes |
| Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
| Storage and transport temperature | -40 ... +85 °C |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -40 °C |
| Mounting | mounting holes plain |
| Degree of pollution | 3 |
| Protection class | III |
| Other Parameters | Operating current: 1,200 | Coding: Individual coding, multiple teaching | Mechanical lifetime, actuator cycles: 500,000 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Rated operating voltage: 24 VDC - 15 % / + 10 % (stabilised PELV) | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Category: 2 | Test pulse duration, maximum: 5 | Note (Manual release): Manual release from side | Interlocking principle: bistable | Note (Relative humidity): non-condensing | EPLAN: Yes | Short circuit detection: Yes | Property class: 8.8 / 80 | Integral system diagnostics, status: Yes | Recommendation (actuator): AZM40-B1-PH | Current consumption at 24V, maximum: 15 | Mechanical lifetime, locking cycles: 1,000,000 | Note (Mechanical lifetime): from device version V2 (V1 = 200.000 actuator cycles) | ACE reference article number: 11931065 | Series-wiring: Yes | Cross-circuit detection: Yes | Installation conditions (mechanical): arbitrarily | PFH value: 3.00 x 10⁻⁹ | Classification ZVEI CB24I, Source: C3 | Voltage, Utilisation category DC-12: 24 | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Current consumption at 24 V: 10 ... 15 mA | PIN 2: X1 Safety input 1 | Relative humidity, maximum: 93 | Designation, Diagnostic outputs: OUT | External wire and device fuse rating: 2 A gG | Design of control elements: OSSD, short-circuit proof, p-type | Classification ZVEI CB24I, Sink: C1 | PFD value: 8.90 x 10⁻⁵ | Latching: Yes | Test pulse interval, minimum: 40 | Magnet switch-on time: 100 | Working principle: RFID | Transmitter output RFID, maximum: -6 | CADENAS: Yes | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Utilisation category DC-12: 24 VDC / 0.25 A | PIN 5: OUT Diagnostic output | Current, Utilisation category DC-12: 0.05 | Tightening torque of the fixing screws: 4 ... 6 Nm | Time to readiness, maximum: 4,000 | Voltage, Utilisation category DC-13: 24 | Safety Integrity Level (SIL), suitable for applications in: 2 | Current, Utilisation category DC-13: 0.05 | Switching frequency, maximum: 0.25 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | REVIEW_ELEC_WIRING_GENERAL_GPV: 1000390331 | Tightening torque of the fixing screws, maximum: 6 | Current consumption magnet at switching moment, peak: 600 mA / 100 ms | TOL_VOLT_OPERAT_DC_MAX: 10 | Reaction time, switching off safety outputs via actuator, maximum: 100 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Unlocking: Rotating unlatcher | Duration of risk, maximum: 200 | Performance Level, up to: e | Frequency band RFID: 125 | Coding level according to EN ISO 14119: High | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | Current consumption at 24V, minimum: 10 | TOL_VOLT_OPERAT_DC_MIN: -15 | Latching force: 40 N | Manual release: Yes | Actuating angle: 180 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Terminal (mechanical): Connector plug M12, 8-pole, A-coded | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Note (Latch force): +/- 25% | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Designation, Safety outputs: Y1 and Y2 | Tightening torque of the fixing screws, minimum: 4 | Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 | Type of the fixing screws: 2x M5 |