Schmersal SRB200EXi-1A (Order No: 103037577) is a genuine safety relays engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Snaps onto standard DIN rail to ...; Ambient t...
Glorient offers competitive supply of Schmersal SRB200EXi-1A, Order No: 103037577. Competitive pricing, fast quotation.
Schmersal SRB200EXi-1A - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal SRB200EXi-1A is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 266 g |
| Net weight | 266 g |
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000079419 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 61508 |
| Certificates | INMETRO |
| Housing material | Glass-fibre reinforced thermoplastic, ventilated |
| EAN (European Article Number) | 4030661544939 |
| Mission time | 15 |
| Mechanical lifetime, minimum | 10,000,000 |
| Material of the contacts, electrical | AgSn0. self-cleaning, positive drive |
| Utilisation category DC-13 | 24 |
| Utilisation category AC-15 | 2 |
| Number of safety contacts | 2 |
| Utilisation category | AC-15 |
| Resistance to vibrations | 10 ... 55 Hz, Amplitude 0.35 mm |
| Storage and transport temperature | -40 ... +85 °C |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -40 °C |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
| Degree of pollution | 2 |
| Other Parameters | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Common Cause Failure (CCF), minimum: 65 | Category, Stop 0: 4 | Note (Wiring diagram): Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range | Performance Level, stop 0, up to: e | Integral system diagnostics, status: Yes | Restistance to shock: 10 g / 11 ms | Terminal designations: IEC/EN 60947-1 | Cross-circuit detection: Yes | Ripple voltage: 10 | Rated control voltage at DC, maximum: 28.8 | Pull-in delay at automatic start, maximum, typically: 300 | Contact resistance, maximum: 0.1 | TOL_VOLT_OPERAT_DC_MIN: -10 | Explosion protection category: 3G | Explosion protection: regulations: EN IEC 60079-0 | Operating voltage: 24 VDC -10 % / +20 % | Earth connection detection: Yes | Conduction resistance, maximum: 30 | Drop-out delay in case of power failure, typically: 20 | Number of LEDs: 5 | TOL_VOLT_OPERAT_DC_MAX: 20 | IP Degree of protection of the installation space: IP54 | Note (applications): Pull-wire emergency stop switches | Number of normally closed (NC): 2 | Cable section: 0.25 mm² ... 2.5 mm² | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | PFH value, Stop 0: 2.00 x 10⁻⁸ | Wire breakage detection : Yes | Pull-in delay at RESET, typically: 20 | Current consumption: 57 | IP Degree of protection of the enclosure: IP40 | Diagnostic Coverage (DC) Level, Stop 0: ≥ 99 | Width: 22.5 | Note (Contact resistance): in new state | Rated operating voltage: 24 | Voltage type: DC | Climatic stress: EN 60068-2-78 | Safety Integrity Level (SIL), Stop 0, suitable for applications in: 3 | Height: 100 | Stop-Category: 0 | Explosion protection zones: 2 | Depth: 121 |
In addition to SRB200EXi-1A, Glorient also supplies:
| Gross weight | 266 g |
| Net weight | 266 g |
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000079419 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 61508 |
| Certificates | INMETRO |
| Housing material | Glass-fibre reinforced thermoplastic, ventilated |
| EAN (European Article Number) | 4030661544939 |
| Mission time | 15 |
| Mechanical lifetime, minimum | 10,000,000 |
| Material of the contacts, electrical | AgSn0. self-cleaning, positive drive |
| Utilisation category DC-13 | 24 |
| Utilisation category AC-15 | 2 |
| Number of safety contacts | 2 |
| Utilisation category | AC-15 |
| Resistance to vibrations | 10 ... 55 Hz, Amplitude 0.35 mm |
| Storage and transport temperature | -40 ... +85 °C |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -40 °C |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
| Degree of pollution | 2 |
| Other Parameters | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Common Cause Failure (CCF), minimum: 65 | Category, Stop 0: 4 | Note (Wiring diagram): Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range | Performance Level, stop 0, up to: e | Integral system diagnostics, status: Yes | Restistance to shock: 10 g / 11 ms | Terminal designations: IEC/EN 60947-1 | Cross-circuit detection: Yes | Ripple voltage: 10 | Rated control voltage at DC, maximum: 28.8 | Pull-in delay at automatic start, maximum, typically: 300 | Contact resistance, maximum: 0.1 | TOL_VOLT_OPERAT_DC_MIN: -10 | Explosion protection category: 3G | Explosion protection: regulations: EN IEC 60079-0 | Operating voltage: 24 VDC -10 % / +20 % | Earth connection detection: Yes | Conduction resistance, maximum: 30 | Drop-out delay in case of power failure, typically: 20 | Number of LEDs: 5 | TOL_VOLT_OPERAT_DC_MAX: 20 | IP Degree of protection of the installation space: IP54 | Note (applications): Pull-wire emergency stop switches | Number of normally closed (NC): 2 | Cable section: 0.25 mm² ... 2.5 mm² | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | PFH value, Stop 0: 2.00 x 10⁻⁸ | Wire breakage detection : Yes | Pull-in delay at RESET, typically: 20 | Current consumption: 57 | IP Degree of protection of the enclosure: IP40 | Diagnostic Coverage (DC) Level, Stop 0: ≥ 99 | Width: 22.5 | Note (Contact resistance): in new state | Rated operating voltage: 24 | Voltage type: DC | Climatic stress: EN 60068-2-78 | Safety Integrity Level (SIL), Stop 0, suitable for applications in: 3 | Height: 100 | Stop-Category: 0 | Explosion protection zones: 2 | Depth: 121 |