Schmersal SRB031MC-24V/1,1SEC (Order No: 101190685) is a genuine safety relays engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Snaps onto standard DIN rail to ...; Am...
Glorient offers competitive supply of Schmersal SRB031MC-24V/1,1SEC, Order No: 101190685. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to SRB031MC-24V/1,1SEC, Glorient also supplies:
| Gross weight | 250 g |
| Net weight | 250 g |
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000079413 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-3 |
| Certificates | TÜV, cULus |
| Housing material | Glass-fibre reinforced thermoplastic, ventilated |
| EAN (European Article Number) | 4250116202256 |
| Mission time | 20 |
| Mechanical lifetime, minimum | 10,000,000 |
| Cable section, maximum | 2.5 mm² |
| Material of the contacts, electrical | AgSn0, Ag-Ni, self-cleaning, positive drive |
| Cable section, minimum | 0.25 mm² |
| Number of safety contacts | 3 |
| Resistance to vibrations | 10 ... 55 Hz, Amplitude 0.35 mm |
| Storage and transport temperature | -40 ... +85 °C |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -40 °C |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Degree of pollution | 2 |
| Other Parameters | Switching capacity, maximum: 250 | Rated AC voltage for controls, 50 Hz, minimum: 20.4 | Rated AC voltage for controls, 60 Hz, minimum: 20.4 | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Common Cause Failure (CCF), minimum: 65 | Electrical power consumption: 4.9 | Rated operating voltage: 24 | Note (applications): Safety light curtain | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 6 A | Current, Utilisation category DC-13: 6 | Integral system diagnostics, status: Yes | Number of LEDs: 4 | Terminal designations: IEC/EN 60947-1 | Rated control voltage at AC 50 Hz, maximum: 26.4 | Cross-circuit detection: Yes | Ripple voltage: 10 | Rated control voltage at DC, maximum: 28.8 | Restistance to shock: 30 g / 11 ms | Indicated operating states: Position relay K1 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Pull-in delay at automatic start, maximum, typically: 100 | Conduction resistance, maximum: 40 | Automatic reset function: Yes | Voltage type: AC | Start input: Yes | Performance Level, stop 1, up to: d | Switching capacity, minimum: 10 | Rated control voltage at AC 60 Hz, maximum: 26.4 | Earth connection detection: Yes | Current, Utilisation category AC-15: 6 | Category, Stop 1: 3 | Terminal (mechanical): Screw terminals | TOL_VOLT_OPERAT_DC_MAX: 20 | IP Degree of protection of the installation space: IP54 | Allowed type of cable: solid single-wire | Cable section: 0.2 mm², rigid0.2 mm², flexible0.25 mm², flexible with ferrule ... 2.5 mm², rigid2.5 mm², flexible2.5 mm², flexible with ferrule | ACE reference article number: 136555 | Stop-Category: 1 | PFH value, Stop 1: 2.00 x 10⁻⁷ | Drop-out delay in case of power failure, typically: 1,100 | Number of normally closed (NC): 2 | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | TOL_VOLT_OPERAT_AC_MIN: -15 | TOL_VOLT_OPERAT_AC_MAX: 10 | Pull-in delay at RESET, typically: 100 | IP Degree of protection of the enclosure: IP40 | TOL_VOLT_OPERAT_DC_MIN: -15 | Width: 22.5 | Note (Contact resistance): in new state | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 6 A | Drop-out delay in case of emergency, typically: 1,100 | Electronic Fuse: Yes | Climatic stress: EN 60068-2-78 | Safety Integrity Level (SIL), Stop 0, suitable for applications in: 3 | Height: 100 | Tightening torque of Clips: 0.6 | Number of signalling outputs: 1 | Voltage, Utilisation category AC-15: 230 | Depth: 121 |