Schmersal SRB101EXi-1R (Order No: 101196283) is a genuine safety relays engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Snaps onto standard DIN rail to ...; Ambient t...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal SRB101EXi-1R, Order No: 101196283. Competitive pricing, fast quotation.

Schmersal SRB101EXi-1R - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal SRB101EXi-1R is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight220 g
Net weight220 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000079417 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 61508
CertificatesINMETRO
Housing materialGlass-fibre reinforced thermoplastic, ventilated
EAN (European Article Number)4250116202355
Mission time15
Mechanical lifetime, minimum10,000,000
Cable section, maximum2.5 mm²
Material of the contacts, electricalAgSn0. self-cleaning, positive drive
Utilisation category DC-1324
Utilisation category AC-152
Cable section, minimum0.25 mm²
Number of safety contacts1
Number of auxiliary contacts1
Utilisation categoryAC-15
Resistance to vibrations10 ... 55 Hz, Amplitude 0.35 mm
Storage and transport temperature-40 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
MountingSnaps onto standard DIN rail to EN 60715
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Degree of pollution2
Other ParametersOvervoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Common Cause Failure (CCF), minimum: 65 | Category, Stop 0: 4 | Note (Wiring diagram): Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range | EPLAN: Yes | Performance Level, stop 0, up to: e | Rated operating voltage: 24 VDC -15%/+20%, residual ripple max. 10% | Integral system diagnostics, status: Yes | Restistance to shock: 10 g / 11 ms | Cable section: 0.25 mm² ... 2.5 mm² | Terminal designations: IEC/EN 60947-1 | Cross-circuit detection: Yes | Ripple voltage: 10 | Reset edge detection: Yes | Rated control voltage at DC, maximum: 28.8 | Pull-in delay at automatic start, maximum, typically: 300 | Contact resistance, maximum: 0.1 | TOL_VOLT_OPERAT_DC_MIN: -10 | Explosion protection category: 3G | Automatic reset function: Yes | Explosion protection: regulations: EN IEC 60079-0 | Start input: Yes | Operating voltage: 24 VDC -10 % / +20 % | Earth connection detection: Yes | Conduction resistance, maximum: 30 | Drop-out delay in case of power failure, typically: 20 | Number of LEDs: 5 | Terminal (mechanical): Screw terminals | TOL_VOLT_OPERAT_DC_MAX: 20 | Note (Delivery capacity): Not available! | IP Degree of protection of the installation space: IP54 | Allowed type of cable: solid single-wire | Note (applications): Pull-wire emergency stop switches | Number of normally closed (NC): 2 | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | PFH value, Stop 0: 2.00 x 10⁻⁸ | Wire breakage detection : Yes | Pull-in delay at RESET, typically: 20 | Current consumption: 57 | IP Degree of protection of the enclosure: IP40 | Diagnostic Coverage (DC) Level, Stop 0: ≥ 99 | Width: 22.5 | Note (Contact resistance): in new state | Voltage type: DC | Electrical power consumption: 3 | Climatic stress: EN 60068-2-78 | Safety Integrity Level (SIL), Stop 0, suitable for applications in: 3 | Height: 100 | Tightening torque of Clips: 0.6 | Stop-Category: 0 | Explosion protection zones: 2 | Depth: 121

More Schmersal Products from Glorient

In addition to SRB101EXi-1R, Glorient also supplies:

SVM1/60-6/223/A Order No: 101213495
T3K 335-11Z-RMS Order No: 151088823
PS216-T02-N200 Order No: 103031907
ESS21S1/EKM191 Order No: 103050345
E-KB9.1SW/L00841117 Order No: 101218132
T4S 236-20Z Order No: 151112893
M3R330-11Y-RMS Order No: 131214708
AZM 161SK-12/12RIA-024G-B1 Order No: 101214826
AV25RKX30U-GB215 Order No: 103016469
PS316-T02-K370 Order No: 103046687
AZM 415-02/11ZPKFE 230VAC Order No: 101186850
BNS 36-02/10Z-R 10,0M Order No: 101217179
BNS 16-12ZV-ST2 Order No: 101195761
TV8S 521-02/20Z Order No: 101138422
ABDECKUNG Order No: 101156716
SHGV/R01/233+BOW Order No: 103015855
AZ201SK-T-1P2P Order No: 103015815
CSS12-34F1-V-D-M-ST Order No: 101188768
TS 235-11Z-2219 Order No: 151159684
TV1H 236-11Z-ST Order No: 151186484
SVE3/107/107/107-24VDC Order No: 101197488
AZ 15 ZVK-M16-1637 Order No: 101174325
GEWINDERING DMN-6 NATUR Order No: 101000562
NWSE7K.1 Order No: 101197431
PWR-1M Order No: 101209127
AV20LHX20U-GB215 Order No: 101142144
ZS 355-01Z-1950 Order No: 151102076

Related Guides

Gross weight220 g
Net weight220 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000079417 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 61508
CertificatesINMETRO
Housing materialGlass-fibre reinforced thermoplastic, ventilated
EAN (European Article Number)4250116202355
Mission time15
Mechanical lifetime, minimum10,000,000
Cable section, maximum2.5 mm²
Material of the contacts, electricalAgSn0. self-cleaning, positive drive
Utilisation category DC-1324
Utilisation category AC-152
Cable section, minimum0.25 mm²
Number of safety contacts1
Number of auxiliary contacts1
Utilisation categoryAC-15
Resistance to vibrations10 ... 55 Hz, Amplitude 0.35 mm
Storage and transport temperature-40 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
MountingSnaps onto standard DIN rail to EN 60715
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Degree of pollution2
Other ParametersOvervoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Common Cause Failure (CCF), minimum: 65 | Category, Stop 0: 4 | Note (Wiring diagram): Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range | EPLAN: Yes | Performance Level, stop 0, up to: e | Rated operating voltage: 24 VDC -15%/+20%, residual ripple max. 10% | Integral system diagnostics, status: Yes | Restistance to shock: 10 g / 11 ms | Cable section: 0.25 mm² ... 2.5 mm² | Terminal designations: IEC/EN 60947-1 | Cross-circuit detection: Yes | Ripple voltage: 10 | Reset edge detection: Yes | Rated control voltage at DC, maximum: 28.8 | Pull-in delay at automatic start, maximum, typically: 300 | Contact resistance, maximum: 0.1 | TOL_VOLT_OPERAT_DC_MIN: -10 | Explosion protection category: 3G | Automatic reset function: Yes | Explosion protection: regulations: EN IEC 60079-0 | Start input: Yes | Operating voltage: 24 VDC -10 % / +20 % | Earth connection detection: Yes | Conduction resistance, maximum: 30 | Drop-out delay in case of power failure, typically: 20 | Number of LEDs: 5 | Terminal (mechanical): Screw terminals | TOL_VOLT_OPERAT_DC_MAX: 20 | Note (Delivery capacity): Not available! | IP Degree of protection of the installation space: IP54 | Allowed type of cable: solid single-wire | Note (applications): Pull-wire emergency stop switches | Number of normally closed (NC): 2 | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | PFH value, Stop 0: 2.00 x 10⁻⁸ | Wire breakage detection : Yes | Pull-in delay at RESET, typically: 20 | Current consumption: 57 | IP Degree of protection of the enclosure: IP40 | Diagnostic Coverage (DC) Level, Stop 0: ≥ 99 | Width: 22.5 | Note (Contact resistance): in new state | Voltage type: DC | Electrical power consumption: 3 | Climatic stress: EN 60068-2-78 | Safety Integrity Level (SIL), Stop 0, suitable for applications in: 3 | Height: 100 | Tightening torque of Clips: 0.6 | Stop-Category: 0 | Explosion protection zones: 2 | Depth: 121