Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

CSS12-34F1-V-D-M-ST

Schmersal CSS12-34F1-V-D-M-ST

Model: CSS12-34F1-V-D-M-ST
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 15 views

Products Introduction

Schmersal CSS12-34F1-V-D-M-ST (Order No: 101188768) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +70 °C; Ambie...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal CSS12-34F1-V-D-M-ST, Order No: 101188768. Competitive pricing, fast quotation.

Schmersal CSS12-34F1-V-D-M-ST - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal CSS12-34F1-V-D-M-ST is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight147 g
Net weight147 g
Ambient temperature-25 ... +70 °C
Ambient temperature, maximum+70 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661354897
Mission time20
TerminationConnector plug M12, 8-pole
Length of sensor35 mm
Width of sensor27 mm
Height of sensor108.2 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Housing construction formBlock
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classII
Other ParametersCurrent derating: Ambient temperature 70°C: ≤ 2 A | Number of fail-safe digital outputs: 2 | Utilisation category DC-12: 24 | PIN 6: X2 Safety input 2 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN without function | Actuating panels: from head | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Duration of risk, maximum: 60 | Switching distance actuator: Actuator CST 180-1 / CST 180-2: 12 mm (typical switch distance Sn) | Wire cross-section: 22 | Cross-circuit detection: Yes | Recommendation (actuator): CST 34-V-1 | Voltage, Utilisation category DC-12: 24 | Recommended safety switchgear: SRB-E-301ST | Operating current: 600 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | PIN 2: X1 Safety input 1 | Traceparts, product ID: 33-22052019-077912 | Design of control elements: p-type | Protection class (Operating resource): 2 | Number of series-wiring of sensors: 31 | Diagnostic output: Yes | Absicherung des Sicherheitsausganges: short-circuit proof | EMC rating: IEC 61000-6-2 | PIN 1: 1A1 Ue: (1) | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Active area: front side | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | PFH value: 3.60 x 10⁻⁹ | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Category: 4 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Number of LEDs: 3 | Input for reset pushbutton, with edge monitoring : Yes | PIN 4: Y1 Safety output 1 | Cable section: 8 mm² | Switching frequency, approx.: 3 | Cascadable: Yes | Safety Integrity Level (SIL), suitable for applications in: 3 | Number of semi-conductor outputs with signaling function: 1 | PIN 5: OUT Diagnostic output OUT | PIN 7: Y2 Safety output 2 | Note (Electrical data, Fuse rating): (Circuit breaker) | Interfering radiation: IEC 61000-6-4 | Absicherung des Diagnoseausganges: short-circuit proof | Hysteresis (Switching distance), maximum: 1.5 | Note (Repeat accuracy R): Axial offset: the front face allows for an axial misalignment (z) of max. ± 8 mm (see figure: operating principle). | Overvoltage category: 3 | Reaction time, maximum: 30 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e

More Schmersal Products from Glorient

In addition to CSS12-34F1-V-D-M-ST, Glorient also supplies:

ZR 332-11Y Order No: 131054557
SVE1/76-3Ö-24VDC Order No: 101197614
TR 355-02Z-RMS Order No: 151215958
T4V7H 335-12Z-M20 Order No: 151172022
SLC440-ER-1370-14-H1 Order No: 103039592
EX-T4VH 355-11Z-3G/D Order No: 151193946
IFL 5-18L-11P Order No: 101138966
PS116-T21-STR-S200 Order No: 103010887
SHGV/LD1/112/62+BO Order No: 101215692
NWSE3K.1 Order No: 101189135
SRB400NE 24V Order No: 101178394
AZM300Z-I1-ST-1P2P Order No: 103001437
BN 120L-01Z/V-2896-1 2,0M Order No: 103010878
BNS 303-11Z-ST-2211 Order No: 101189841
SHGV/B01/103+BOF/HIS2 Order No: 101198320
NBG664/NM Order No: 101182351
AZ 15 ZVRK-M20-2254 Order No: 101164455
TZFSP24VDC Order No: 131157874
BN 20-11RZ-M16 Order No: 101165310
Z1K 335-11Z-1637 Order No: 151149541
TR 335-11Z-M20 Order No: 151167924
MS 6600-11-K-Y -1464-1 O.BEZ. Order No: 101062075
WSCN32 Order No: 101007349
GS38300143 230 Order No: 103010174
SHGV/D01/215+BOWR Order No: 101198429
SVE2/201/202/EMLWS/W-24VDC Order No: 103000852
TV1H 236-11Z-M20 Order No: 151160988

Related Guides

Gross weight147 g
Net weight147 g
Ambient temperature-25 ... +70 °C
Ambient temperature, maximum+70 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialGlass-fibre, reinforced thermoplastic
EAN (European Article Number)4030661354897
Mission time20
TerminationConnector plug M12, 8-pole
Length of sensor35 mm
Width of sensor27 mm
Height of sensor108.2 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Housing construction formBlock
Safety functionsYes
Resistance to vibrations10 … 55 Hz, amplitude 1 mm
Storage and transport temperature-25 ... +85 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classII
Other ParametersCurrent derating: Ambient temperature 70°C: ≤ 2 A | Number of fail-safe digital outputs: 2 | Utilisation category DC-12: 24 | PIN 6: X2 Safety input 2 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN without function | Actuating panels: from head | EPLAN: Yes | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Duration of risk, maximum: 60 | Switching distance actuator: Actuator CST 180-1 / CST 180-2: 12 mm (typical switch distance Sn) | Wire cross-section: 22 | Cross-circuit detection: Yes | Recommendation (actuator): CST 34-V-1 | Voltage, Utilisation category DC-12: 24 | Recommended safety switchgear: SRB-E-301ST | Operating current: 600 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | PIN 2: X1 Safety input 1 | Traceparts, product ID: 33-22052019-077912 | Design of control elements: p-type | Protection class (Operating resource): 2 | Number of series-wiring of sensors: 31 | Diagnostic output: Yes | Absicherung des Sicherheitsausganges: short-circuit proof | EMC rating: IEC 61000-6-2 | PIN 1: 1A1 Ue: (1) | Current, Utilisation category DC-12: 0.05 | Repeat accuracy R: 0.5 | Active area: front side | Voltage, Utilisation category DC-13: 24 | Sensor topology: Sensor for series wiring | PFH value: 3.60 x 10⁻⁹ | Installation conditions (mechanical): not flush | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Category: 4 | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | Number of LEDs: 3 | Input for reset pushbutton, with edge monitoring : Yes | PIN 4: Y1 Safety output 1 | Cable section: 8 mm² | Switching frequency, approx.: 3 | Cascadable: Yes | Safety Integrity Level (SIL), suitable for applications in: 3 | Number of semi-conductor outputs with signaling function: 1 | PIN 5: OUT Diagnostic output OUT | PIN 7: Y2 Safety output 2 | Note (Electrical data, Fuse rating): (Circuit breaker) | Interfering radiation: IEC 61000-6-4 | Absicherung des Diagnoseausganges: short-circuit proof | Hysteresis (Switching distance), maximum: 1.5 | Note (Repeat accuracy R): Axial offset: the front face allows for an axial misalignment (z) of max. ± 8 mm (see figure: operating principle). | Overvoltage category: 3 | Reaction time, maximum: 30 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e