Schmersal SRB400NE 24V (Order No: 101178394) is a genuine safety relays engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Snaps onto standard DIN rail to ...; Ambient t...
Glorient offers competitive supply of Schmersal SRB400NE 24V, Order No: 101178394. Competitive pricing, fast quotation.
Schmersal industrial automation component. Replacement part/accessory for Schmersal safety switch systems.
In addition to SRB400NE 24V, Glorient also supplies:
| Gross weight | 350 g |
| Net weight | 350 g |
| Ambient temperature | -25 ... +45 °C |
| Ambient temperature, maximum | 1000079489 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-3 |
| Certificates | cULus |
| Housing material | Glass-fibre reinforced thermoplastic, ventilated |
| EAN (European Article Number) | 4250116202393 |
| Mission time | 20 |
| Mechanical lifetime, minimum | 10,000,000 |
| Cable section, maximum | 2.5 mm² |
| Material of the contacts, electrical | Ag-Ni, self-cleaning, positive drive |
| Cable section, minimum | 0.25 mm² |
| Number of safety contacts | 4 |
| Resistance to vibrations | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
| Storage and transport temperature | -40 ... +85 °C |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -40 °C |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
| Degree of pollution | 2 |
| Other Parameters | Switching capacity, maximum: 250 | Rated AC voltage for controls, 50 Hz, minimum: 20.4 | Rated AC voltage for controls, 60 Hz, minimum: 20.4 | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Common Cause Failure (CCF), minimum: 65 | Category, Stop 0: 4 | Cable section: 0.25 mm² ... 2.5 mm² | Rated operating voltage: 24 | Electrical power consumption: 6 | ACE reference article number: 136493 | Drop-out delay in case of emergency, typically: 20 | Performance Level, stop 0, up to: e | Integral system diagnostics, status: Yes | Terminal designations: IEC/EN 60947-1 | Rated control voltage at AC 50 Hz, maximum: 26.4 | Cross-circuit detection: Yes | Ripple voltage: 10 | Current, Utilisation category DC-13: 4 | Rated control voltage at DC, maximum: 28.8 | Restistance to shock: 30 g / 11 ms | Note (Wiring diagram): (H2) = Feedback circuit | Replacement article number: 101178528 | Indicated operating states: Position relay K1 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Pull-in delay at automatic start, maximum, typically: 100 | Conduction resistance, maximum: 40 | Automatic reset function: Yes | Voltage type: AC | Switching capacity, minimum: 10 | Rated control voltage at AC 60 Hz, maximum: 26.4 | Earth connection detection: Yes | PFH value: 2.00 x 10⁻⁸ | Width: 45 | Terminal (mechanical): Screw terminals | TOL_VOLT_OPERAT_DC_MAX: 20 | IP Degree of protection of the installation space: IP54 | Drop-out delay in case of power failure, typically: 80 | Allowed type of cable: solid single-wire | Number of LEDs: 7 | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 4 A | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | TOL_VOLT_OPERAT_AC_MIN: -15 | Pull-in delay at RESET, typically: 20 | Current, Utilisation category AC-15: 4 | TOL_VOLT_OPERAT_AC_MAX: 10 | Removable Terminals: Yes | IP Degree of protection of the enclosure: IP40 | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 4 A | TOL_VOLT_OPERAT_DC_MIN: -15 | Diagnostic Coverage (DC) Level, Stop 0: ≥ 99 | Note (Contact resistance): in new state | Note (applications): Safety sensor | Climatic stress: EN 60068-2-78 | Safety Integrity Level (SIL), Stop 0, suitable for applications in: 3 | Height: 100 | Tightening torque of Clips: 0.6 | Stop-Category: 0 | Number of normally closed (NC): 4 | Voltage, Utilisation category AC-15: 230 | Depth: 121 |