Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

OLS-2, OSA-SC

OLS-2, OSA-SC

Model: OLS-2, OSA-SC
Brand: WIKA Stock
Category: Level Measurement
Views: 11 views

Products Introduction

WIKA OLS-2, OSA-SC is a genuine level measurement engineered for demanding industrial applications. Manufactured to original WIKA quality standards. Specifications: Product Category: Level Measurement; Product Type: Optoelectronic switches; Summary...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of WIKA OLS-2, OSA-SC. Competitive pricing, fast quotation.

WIKA OLS-2, OSA-SC - high-precision industrial measurement instrument.

Product Introduction

WIKA is a global market leader in pressure and temperature measurement technology. With over 75 years of experience, WIKA instruments are trusted in process industries worldwide. Glorient is a professional supplier of genuine WIKA products with competitive pricing and fast worldwide delivery.

Applications

  • Cryogenic applications (liquid gas) Chemical industry, petrochemical industry, natural gas, offshore Shipbuilding, machine building, refrigerator units Power generating equipment, power plants Process water and drinking water treatment

Technical Specifications

Product CategoryLevel Measurement
Product TypeOptoelectronic switches
SummaryFor the process industry
ApplicationsCryogenic applications (liquid gas) Chemical industry, petrochemical industry, natural gas, offshore Shipbuilding, machine building, refrigerator units Power generating equipment, power plants Process water and drinking water treatment
Key FeaturesTemperature ranges from -269 ... +400 °C [-452 ... +752 °F] Versions for pressure ranges from vacuum to 500 bar [7,252 psi] Special versions: High pressure, interface measurement Explosion-protected versions Signal processing is made using a separate model OSA-SC switching amplifier
DescriptionThe model OLS-2 optoelectronic level switch is used for the detection of limit levels in liquids. The OLS-2 operates widely independent of physical characteristics such as refractive index, colour, density, dielectric constant and conductivity. Measurement of level change is also done in small volumes. The model OLS-2 limit level switch consists of an infrared LED and a phototransistor. The light of the LED is directed into a prism. So long as the sensor tip of the prism is in the gaseous phase, the light is reflected within the prism to the receiver. When the liquid in the vessel rises and wets approximately 2/3 of the glass tip, the infrared light beam into the liquid is interrupted and only a small portion reaches the receptor. This difference is evaluated by the electronics and triggers a switching operation. The instruments are very robust and designed for rough operating conditions. The installation position can be as required. Thus, the OLS-2 can be installed from above, from below, vertically, horizontally or at an angle. The cable to the model OSA-SC switching amplifier does not need any shield, enabling easy and economic cabling. The change in the alarm direction, the sensitivity of the switching threshold, as well as a time delay of up to 8 seconds can be easily transferred to the OSA-SC via Bluetooth ® app and changed individually.

More WIKA Products

s FLM-TB, FLM-TH  |  GCx-06  |  magWIK  |  TC10-3  |  TC59-V  |  300-2.75I  |  s 432.30, 433.30  |  700.04  |  830.1E  |  910.15  |  910.32.100  |  990.18, 990.19, 990.20, 990.21  |  990.41  |  A2G-500  |  BV  |  CPP7000-X  |  CTD9100-375  |  DA, DA10  |  DPGS40TA  |  F2220  |  F3203  |  F5301, F53C1  |  F9304, F93C4  |  FLC-UFL  |  GDM-063  |  GLTC10 combination valve  |  HPCV  |  IV1  |  s M932.3A, M933.3A  |  N1301

Related Guides

Product CategoryLevel Measurement
Product TypeOptoelectronic switches
SummaryFor the process industry
ApplicationsCryogenic applications (liquid gas) Chemical industry, petrochemical industry, natural gas, offshore Shipbuilding, machine building, refrigerator units Power generating equipment, power plants Process water and drinking water treatment
Key FeaturesTemperature ranges from -269 ... +400 °C [-452 ... +752 °F] Versions for pressure ranges from vacuum to 500 bar [7,252 psi] Special versions: High pressure, interface measurement Explosion-protected versions Signal processing is made using a separate model OSA-SC switching amplifier
DescriptionThe model OLS-2 optoelectronic level switch is used for the detection of limit levels in liquids. The OLS-2 operates widely independent of physical characteristics such as refractive index, colour, density, dielectric constant and conductivity. Measurement of level change is also done in small volumes. The model OLS-2 limit level switch consists of an infrared LED and a phototransistor. The light of the LED is directed into a prism. So long as the sensor tip of the prism is in the gaseous phase, the light is reflected within the prism to the receiver. When the liquid in the vessel rises and wets approximately 2/3 of the glass tip, the infrared light beam into the liquid is interrupted and only a small portion reaches the receptor. This difference is evaluated by the electronics and triggers a switching operation. The instruments are very robust and designed for rough operating conditions. The installation position can be as required. Thus, the OLS-2 can be installed from above, from below, vertically, horizontally or at an angle. The cable to the model OSA-SC switching amplifier does not need any shield, enabling easy and economic cabling. The change in the alarm direction, the sensitivity of the switching threshold, as well as a time delay of up to 8 seconds can be easily transferred to the OSA-SC via Bluetooth ® app and changed individually.