MZM 100 ST2-1P2PWREM-A

Schmersal MZM 100 ST2-1P2PWREM-A

Model: MZM 100 ST2-1P2PWREM-A
Brand: Schmersal
Category: Safety Door Switches / Magnetic Switches
Views: 17 views

Products Introduction

Schmersal MZM 100 ST2-1P2PWREM-A (Order No: 101211067) is a genuine safety door switches engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -25 ... +55 °C; Am...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal MZM 100 ST2-1P2PWREM-A, Order No: 101211067. Competitive pricing, fast quotation.

Schmersal MZM 100 ST2-1P2PWREM-A - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal MZM 100 ST2-1P2PWREM-A is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight698 g
Net weight698 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661389134
Mission time20
TerminationConnector M12, 8-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor177.5 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Latching force, maximum: 115 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | External wire and device fuse rating: 2 A gG (Connector M12, 8-pole) | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Designation, Diagnostic outputs: OUT | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | Latching force, minimum: 45 | CADENAS: Yes | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Rated operating voltage: 24 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | FORCE_LATCH_GPV: 45 ... 115 N | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Current consumption with magnet ON, average : 350 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | VOLT_TYPE_DIAGN_OUT: DC | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | ACE reference article number: 11930101 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole

More Schmersal Products from Glorient

In addition to MZM 100 ST2-1P2PWREM-A, Glorient also supplies:

AZM400Z-ST-1P2P Order No: 103003590
M 6800-11-3-P3-80E Order No: 101061885
SLC440COM-R-0970-35-1700 Order No: 103040560
ZK 236-11Z-M20-U180-2219 Order No: 151161269
Z4VH 336-02Z-RMS Order No: 153001161
PS116-Z11-LR200-K230 Order No: 103006571
EF103.3 Order No: 101006549
SLC445-ER-0490-14-01 Order No: 103005390
ZS 256-11Z-M20-2219 Order No: 151156956
T4V. 336-02Z-U270-2525-1 10,0M Order No: 151186093
TQ215AR-11 Order No: 103044929
HEBEL 10H KPL. KUNSTOFFSTAB Order No: 101121642
BNS 180-12Z-2187-2 3,0M Order No: 101184069
T. 471-02/02Y-H GB 496 Order No: 101061078
SLC440COM-R-0490-35-1700 Order No: 103040554
T4V1H 335-11Z Order No: 153010615
SVE1/100-24VDC Order No: 101197191
PS216-Z11-M16-K200 Order No: 103049218
G50-017M44/22Y Order No: 103002802
SHGV/LD1/261/361+BOW Order No: 103039410
SHGV/ESS21S2/111/103 Order No: 101205809
AZM 415-02/11ZPKFE 24VAC/DC Order No: 101192999
RDLWS/305D Order No: 103006539
SVM1/65-6/115/A Order No: 103000398
NDRZ50BL/RT-2905-1 Order No: 103011891
Z4S 256-11Z-M20 Order No: 151168186
T1K 335-02Z-M20 Order No: 151165928
SHGV/L01/100+BO Order No: 101197780

Related Guides

Gross weight698 g
Net weight698 g
Ambient temperature-25 ... +55 °C
Ambient temperature, maximum+55 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
IP Degree of protectionIP67
CertificatescULus
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
EAN (European Article Number)4030661389134
Mission time20
TerminationConnector M12, 8-pole
Mechanical lifetime, minimum1,000,000
Length of sensor40 mm
Width of sensor40 mm
Height of sensor177.5 mm
Utilisation category DC-1324 VDC / 0.25 A
Required rated short-circuit current100 A
TracepartsYes
Safety functionsYes
Resistance to vibrations10 … 150 Hz, amplitude 0.35 mm / 5 g
Storage and transport temperature-25 ... +70 °C
Scope of deliveryActuator must be ordered separately.
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Degree of pollution3
Protection classIII
Other ParametersReaction time, maximum: 150 | Number of fail-safe digital outputs: 2 | Switching thresholds: -3 V … 5 V (Low) | PIN 6: X2 Safety input 2 | Designation, Safety inputs: X1 and X2 | Note (LED switching conditions display): Error / functional defect: LED red | Latching force, maximum: 115 | PIN 3: A2 GND | Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current | PIN 8: IN Solenoid control | Minimum distance devices: 100 | Test pulse duration, maximum: 5 | Holding force, typically: 750 | Design of control elements: short-circuit proof, p-type | Note (Mechanical lifetime): Actuating speed ≤ 0.5 m/s | Note (Relative humidity): non-condensing | EPLAN: Yes | Relative humidity: 30 ... 95 % | Short circuit detection: Yes | Integral system diagnostics, status: Yes | Recommendation (actuator): MZM 100-B1.1 | Coding level according to EN ISO 14119: Low | Series-wiring: Yes | Operating voltage, maximum: 26.4 | Cross-circuit detection: Yes | External wire and device fuse rating: 2 A gG (Connector M12, 8-pole) | Switching frequency, maximum: 1 | Classification ZVEI CB24I, Source: C3 | Category: 4 | Working principle: inductive | Restistance to shock: 30 g / 11 ms | NOTE_VOLT_OPERAT_DC: stabilised PELV power supply | Power to lock: Yes | PIN 2: X1 Safety input 1 | Fuse rating to UL 508, maximum: 2 | Designation, Diagnostic outputs: OUT | Coding: Universal coding | Classification ZVEI CB24I, Sink: C1 | Latching: Yes | Test pulse interval, minimum: 40 | Operating current: 1,100 | Magnet switch-on time: 100 | Latching force: 15 / 30 / 45 / 60 / 100 N | Type of the fixing screws: 2x M6 | Latching force, minimum: 45 | CADENAS: Yes | Current consumption with magnet ON, peak: 550 mA / 10 ms | Note (switching distance): All switching distances in accordance EN IEC 60947-5-3 | Current consumption at 24 V: 5 | Operating voltage, minimum: 20.4 | PIN 5: OUT Diagnostic output | Duration of risk, maximum: 150 | Time to readiness, maximum: 4,000 | PFH value: 3.54 x 10⁻⁹ | Voltage, Utilisation category DC-13: 24 | Current, Utilisation category DC-13: 0.05 | Rated operating current (safety outputs): 250 | Holding force, guaranteed: 500 | Rated operating voltage: 24 | Absicherung des Diagnoseausganges: short-circuit proof, p-type | Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD | TOL_VOLT_OPERAT_DC_MAX: 10 | PIN 4: Y1 Safety output 1 | Designation, Magnet control: IN | Performance Level, up to: e | FORCE_LATCH_GPV: 45 ... 115 N | Tightening torque of the fixing screws: 8 | Relative humidity, minimum: 30 | Relative humidity, maximum: 95 | Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply) | TOL_VOLT_OPERAT_DC_MIN: -15 | Current consumption with magnet ON, average : 350 | PIN 7: Y2 Safety output 2 | Voltage type: DC | Length of sensor chain, maximum: 200 | VOLT_TYPE_DIAGN_OUT: DC | PIN 1: A1 Supply voltage UB | Number of digital fail-safe inputs : 2 | Angular misalignment between solenoid interlock and actuator, maximum: 2 | Solenoid interlock monitored: Yes | Permissible installation altitude above sea level, maximum: 2,000 | Safety Integrity Level (SIL), suitable for applications in: 3 | ACE reference article number: 11930101 | Overvoltage category: 3 | Protection class (Operating resource): 3 | Test pulse interval, typical: 1,000 | Electrical fuse rating: short-circuit proof, p-type | Designation, Safety outputs: Y1 and Y2 | REVIEW_ELEC_WIRING_GENERAL_GPV: Connector M12, 8-pole