Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

SLG440COM-ER-0800-03

Schmersal SLG440COM-ER-0800-03

Model: SLG440COM-ER-0800-03
Brand: Schmersal
Category: Safety Light Curtains
Views: 21 views

Products Introduction

Schmersal SLG440COM-ER-0800-03 (Order No: 103004063) is a genuine safety light curtains engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Ambient temperature: -10 ... +50 °C; Amb...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal SLG440COM-ER-0800-03, Order No: 103004063. Competitive pricing, fast quotation.

Schmersal SLG440COM-ER-0800-03 - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal SLG440COM-ER-0800-03 is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight1,420 g
Net weight1,420 g
Ambient temperature-10 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-10 °C
StandardsEN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661435749
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
Height of sensor871 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Bluetooth transmission frequency: 2.400 … 2.483 | Number of fail-safe digital outputs: 2 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Designation, Control inputs: Release / restart interlock | Bluetooth transmission power, maximum: 2 | Radiation emission level to EN 12198-1: Category 0 | EPLAN: Yes | Integral system diagnostics, status: Yes | Switching voltage: 0 … 2 V (LOW) | PIN 4: Do not connect a signal (do not wire) | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Note (Software Version): as of 2024 Version 4.0 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | LED position: Emitter | PIN 2: OSSD 1 Safety output 1 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | PIN 5: Release/restart interlock Acknowledgement restart interlock | CADENAS: Yes | Height of the protection field: 800 | Restart interlock (manual reset): Yes | TOL_VOLT_OPERAT_DC_MAX: 20 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Length of cable: 100 | Recommended safety switchgear: SRB-E 301 | PIN 1: 24 VDC power supply | Range, protection field, maximum: 12 | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Detection ability for test bodies at v = 1.6 m/s: 400 | TOL_VOLT_OPERAT_DC_MIN: -20 | Note (applications): protective mode/automatic, restart interlock, setting mode | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Number of beams: 3 | Terminal connector, Recipient: Connector plug M12, 5-pole | Safety Integrity Level (SIL), suitable for applications in: 3 | Rated operating voltage: 24 | LED status: transmitting and status | Connection: Emitter | Test pulse interval, typical: 750 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Safety type in accordance with IEC 61496-1: 4 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e

More Schmersal Products from Glorient

In addition to SLG440COM-ER-0800-03, Glorient also supplies:

TV14H 236-11Z-1058 Order No: 151103950
T. 067-01/01Y Order No: 101060696
PS116-T12-STR-H200 Order No: 103006632
SMS 4-800-1100-0395 Order No: 103051137
SHGV/B1.1/105+BOW Order No: 103000698
ZR 335-11Z-ST Order No: 151154292
TL 441-11Y-1801-RMS Order No: 101195076
IFL 8-18L-11P Order No: 101139936
SMS 5-300-1045 Order No: 103012413
BDF200-NH-10-LT-LT-LT-G24-2875 Order No: 103007781
MK 330-11Y-M20 Order No: 101163173
Z4VH 332-11Y-1172 Order No: 101054584
SHGV/LD1/210/31+BO Order No: 101198511
EX-BNS 250-11Z-3GD 20M Order No: 103045521
SHGV/L01/50+BO Order No: 103015931
E-KB9WS/L00841189 Order No: 101218488
E-KB9WS/L00841135 Order No: 101218444
SHGV/L01/220+BO Order No: 101197901
WSCN21 Order No: 101007329
BN 650-10Z/V 3,0M Order No: 103000634
TV. 016-03Y Order No: 131060212
SMS 4-840-850-0383 Order No: 103051049
SVE2/153/153-3Ö-24VDC Order No: 103035508
AZM 415-11/11XPKRS 230VAC Order No: 101167200
T4VH 336-11YR-1058 Order No: 151142571
TQ 441-01/01Y-UE-R -1572 Order No: 101080226
BNS 120-11Z 10,0M Order No: 101147200
BN 20-10E SCHALTROHRWANNE Order No: 101057115
AV20RX40U-GB215 Order No: 103016450
SLC440-ER-0330-14-01 Order No: 101216617

Related Guides

Gross weight1,420 g
Net weight1,420 g
Ambient temperature-10 ... +50 °C
Ambient temperature, maximum+50 °C
Ambient temperature, minimum-10 °C
StandardsEN IEC 61496-1
IP Degree of protectionIP67
CertificatescULus
Housing materialAluminium
EAN (European Article Number)4030661435749
Mission time20
TerminationConnector
Length of sensor33 mm
Width of sensor27.8 mm
Height of sensor871 mm
NoteIn case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state.
TracepartsYes
Resistance to vibrations10 … 55 Hz
Storage and transport temperature-25 ... +70 °C
Scope of deliveryKit with 2 mounting angles
Storage and transport temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Protection classIII
Other ParametersReaction time, maximum: 10 | Bluetooth transmission frequency: 2.400 … 2.483 | Number of fail-safe digital outputs: 2 | Range, protection field, minimum: 0.3 | Actuation time for manual start: 100 … 1500 | Designation, Control inputs: Release / restart interlock | Bluetooth transmission power, maximum: 2 | Radiation emission level to EN 12198-1: Category 0 | EPLAN: Yes | Integral system diagnostics, status: Yes | Switching voltage: 0 … 2 V (LOW) | PIN 4: Do not connect a signal (do not wire) | Tolerance, percentage: 10 | Rated operating current, Emitter: 200 | Note (Software Version): as of 2024 Version 4.0 | Risk group classification of lamp systems to EN 62471: free group | Rated operating current, Receiver: 700 | LED position: Emitter | PIN 2: OSSD 1 Safety output 1 | Design of control elements: OSSD, short-circuit proof, p-type | Integral system diagnostics: Yes | Load inductance, maximum: 2 | PIN 5: Release/restart interlock Acknowledgement restart interlock | CADENAS: Yes | Height of the protection field: 800 | Restart interlock (manual reset): Yes | TOL_VOLT_OPERAT_DC_MAX: 20 | Classification ZVEI CB24I, Sink: C1 | Category: 4 | Length of cable: 100 | Recommended safety switchgear: SRB-E 301 | PIN 1: 24 VDC power supply | Range, protection field, maximum: 12 | Terminal, Connector, Transmitter: Connector plug M12, 4-pole | Detection ability for test bodies at v = 1.6 m/s: 400 | TOL_VOLT_OPERAT_DC_MIN: -20 | Note (applications): protective mode/automatic, restart interlock, setting mode | Designation, Safety outputs: OSSD 1 and OSSD 2 | Load capacity, maximum: 0.05 | Number of beams: 3 | Terminal connector, Recipient: Connector plug M12, 5-pole | Safety Integrity Level (SIL), suitable for applications in: 3 | Rated operating voltage: 24 | LED status: transmitting and status | Connection: Emitter | Test pulse interval, typical: 750 | PIN 3: 0 VDC power supply | Restistance to shock: 10 g, 16 ms, to EN 60028-2-29 | Protection class (Operating resource): 3 | Safety type in accordance with IEC 61496-1: 4 | Test pulse duration, maximum: 0.15 | Wave length of the laserdiode: 880 | PFH value: 8.05 x 10⁻⁹ | Classification ZVEI CB24I, Source: C2 | Output current, (fail-safe output), maximum: 0.25 | Performance Level, up to: e