Schmersal SRB-E-402EM (Order No: 103041198) is a genuine safety relays engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Snaps onto standard DIN rail to ...; Ambient te...
Glorient offers competitive supply of Schmersal SRB-E-402EM, Order No: 103041198. Competitive pricing, fast quotation.
Schmersal SRB-E-402EM - industrial safety component from Schmersal, the global leader in safety switchgear.
The Schmersal SRB-E-402EM is designed for reliable machine safety performance and long service life in demanding industrial environments.
Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.
| Gross weight | 250 g |
| Net weight | 250 g |
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000731698 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-3 |
| Certificates | cULus, CCC |
| Housing material | Glass-fibre reinforced thermoplastic, ventilated |
| EAN (European Article Number) | 4030661563411 |
| Mission time | 20 |
| Mechanical lifetime, minimum | 10,000,000 |
| Cable section, maximum | 2.5 mm² |
| Material of the contacts, electrical | Ag-Ni, self-cleaning, positive drive |
| Cable section, minimum | 0.25 mm² |
| Number of safety contacts | 4 |
| Number of auxiliary contacts | 2 |
| Traceparts | Yes |
| Resistance to vibrations | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
| Storage and transport temperature | -40 ... +85 °C |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -40 °C |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
| Degree of pollution | 2 |
| Other Parameters | Switching capacity, maximum: 250 | Rated AC voltage for controls, 50 Hz, minimum: 20.4 | Rated AC voltage for controls, 60 Hz, minimum: 20.4 | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Common Cause Failure (CCF), minimum: 65 | Category, Stop 0: 4 | Rated operating voltage: 24 | EPLAN: Yes | Performance Level, stop 0, up to: e | Integral system diagnostics, status: Yes | Restistance to shock: 10 g / 11 ms | Rated control voltage at AC 50 Hz, maximum: 26.4 | Ripple voltage: 10 | Current, Utilisation category DC-13: 4 | Rated control voltage at DC, maximum: 28.8 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Conduction resistance, maximum: 40 | Automatic reset function: Yes | Indicated operating states: Position relay K1/K2 | Voltage type: AC | Terminal designations: EN 60947-1 | Number of LEDs: 1 | Switching capacity, minimum: 10 | CADENAS: Yes | Rated control voltage at AC 60 Hz, maximum: 26.4 | Earth connection detection: Yes | Number of normally closed (NC): 1 | TOL_VOLT_OPERAT_DC_MAX: 20 | IP Degree of protection of the installation space: IP54 | Allowed type of cable: solid single-wire | Height: 98 | Cable section: 0.2 mm², rigid0.2 mm², flexible0.25 mm², flexible with ferrule ... 2.5 mm², rigid2.5 mm², flexible2.5 mm², flexible with ferrule | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 4 A | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | PFH value, Stop 0: 2.00 x 10⁻⁸ | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | TOL_VOLT_OPERAT_AC_MIN: -15 | Current, Utilisation category AC-15: 4 | TOL_VOLT_OPERAT_AC_MAX: 10 | Removable Terminals: Yes | IP Degree of protection of the enclosure: IP40 | Pull-in delay at automatic start, maximum, typically: 20 | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 4 A | TOL_VOLT_OPERAT_DC_MIN: -15 | Diagnostic Coverage (DC) Level, Stop 0: ≥ 99 | Width: 22.5 | Note (Contact resistance): in new state | Depth: 115 | Climatic stress: EN 60068-2-78 | Safety Integrity Level (SIL), Stop 0, suitable for applications in: 3 | Tightening torque of Clips: 0.5 | Electrical power consumption: 2.2 | Drop-out delay, maximum: 35 | Stop-Category: 0 | Voltage, Utilisation category AC-15: 230 | Terminal (mechanical): Removable screw terminals |
In addition to SRB-E-402EM, Glorient also supplies:
| Gross weight | 250 g |
| Net weight | 250 g |
| Ambient temperature | -25 ... +60 °C |
| Ambient temperature, maximum | 1000731698 °C |
| Ambient temperature, minimum | -25 °C |
| Standards | EN IEC 60947-5-3 |
| Certificates | cULus, CCC |
| Housing material | Glass-fibre reinforced thermoplastic, ventilated |
| EAN (European Article Number) | 4030661563411 |
| Mission time | 20 |
| Mechanical lifetime, minimum | 10,000,000 |
| Cable section, maximum | 2.5 mm² |
| Material of the contacts, electrical | Ag-Ni, self-cleaning, positive drive |
| Cable section, minimum | 0.25 mm² |
| Number of safety contacts | 4 |
| Number of auxiliary contacts | 2 |
| Traceparts | Yes |
| Resistance to vibrations | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
| Storage and transport temperature | -40 ... +85 °C |
| Storage and transport temperature, maximum | +85 °C |
| Storage and transport temperature, minimum | -40 °C |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
| Degree of pollution | 2 |
| Other Parameters | Switching capacity, maximum: 250 | Rated AC voltage for controls, 50 Hz, minimum: 20.4 | Rated AC voltage for controls, 60 Hz, minimum: 20.4 | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Common Cause Failure (CCF), minimum: 65 | Category, Stop 0: 4 | Rated operating voltage: 24 | EPLAN: Yes | Performance Level, stop 0, up to: e | Integral system diagnostics, status: Yes | Restistance to shock: 10 g / 11 ms | Rated control voltage at AC 50 Hz, maximum: 26.4 | Ripple voltage: 10 | Current, Utilisation category DC-13: 4 | Rated control voltage at DC, maximum: 28.8 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Conduction resistance, maximum: 40 | Automatic reset function: Yes | Indicated operating states: Position relay K1/K2 | Voltage type: AC | Terminal designations: EN 60947-1 | Number of LEDs: 1 | Switching capacity, minimum: 10 | CADENAS: Yes | Rated control voltage at AC 60 Hz, maximum: 26.4 | Earth connection detection: Yes | Number of normally closed (NC): 1 | TOL_VOLT_OPERAT_DC_MAX: 20 | IP Degree of protection of the installation space: IP54 | Allowed type of cable: solid single-wire | Height: 98 | Cable section: 0.2 mm², rigid0.2 mm², flexible0.25 mm², flexible with ferrule ... 2.5 mm², rigid2.5 mm², flexible2.5 mm², flexible with ferrule | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 4 A | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | PFH value, Stop 0: 2.00 x 10⁻⁸ | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | TOL_VOLT_OPERAT_AC_MIN: -15 | Current, Utilisation category AC-15: 4 | TOL_VOLT_OPERAT_AC_MAX: 10 | Removable Terminals: Yes | IP Degree of protection of the enclosure: IP40 | Pull-in delay at automatic start, maximum, typically: 20 | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 4 A | TOL_VOLT_OPERAT_DC_MIN: -15 | Diagnostic Coverage (DC) Level, Stop 0: ≥ 99 | Width: 22.5 | Note (Contact resistance): in new state | Depth: 115 | Climatic stress: EN 60068-2-78 | Safety Integrity Level (SIL), Stop 0, suitable for applications in: 3 | Tightening torque of Clips: 0.5 | Electrical power consumption: 2.2 | Drop-out delay, maximum: 35 | Stop-Category: 0 | Voltage, Utilisation category AC-15: 230 | Terminal (mechanical): Removable screw terminals |