SRB-E-402EM

Schmersal SRB-E-402EM

Model: SRB-E-402EM
Brand: Schmersal
Category: Safety Relays / Safety PLC
Views: 20 views

Products Introduction

Schmersal SRB-E-402EM (Order No: 103041198) is a genuine safety relays engineered for demanding industrial applications. Manufactured to original Schmersal quality standards. Specifications: Mounting: Snaps onto standard DIN rail to ...; Ambient te...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of Schmersal SRB-E-402EM, Order No: 103041198. Competitive pricing, fast quotation.

Schmersal SRB-E-402EM - industrial safety component from Schmersal, the global leader in safety switchgear.

Product Introduction

The Schmersal SRB-E-402EM is designed for reliable machine safety performance and long service life in demanding industrial environments.

Schmersal is a global leader in industrial safety switchgear and automation solutions. Founded in 1945 in Wuppertal, Germany, Schmersal develops and manufactures safety switches, sensors, and systems for machine and plant engineering worldwide. Glorient is a professional supplier of genuine Schmersal products with competitive pricing and fast worldwide delivery.

Technical Specifications

Gross weight250 g
Net weight250 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000731698 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
CertificatescULus, CCC
Housing materialGlass-fibre reinforced thermoplastic, ventilated
EAN (European Article Number)4030661563411
Mission time20
Mechanical lifetime, minimum10,000,000
Cable section, maximum2.5 mm²
Material of the contacts, electricalAg-Ni, self-cleaning, positive drive
Cable section, minimum0.25 mm²
Number of safety contacts4
Number of auxiliary contacts2
TracepartsYes
Resistance to vibrations10...55 Hz, Amplitude 0.35 mm, ± 15 %
Storage and transport temperature-40 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
MountingSnaps onto standard DIN rail to EN 60715
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Degree of pollution2
Other ParametersSwitching capacity, maximum: 250 | Rated AC voltage for controls, 50 Hz, minimum: 20.4 | Rated AC voltage for controls, 60 Hz, minimum: 20.4 | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Common Cause Failure (CCF), minimum: 65 | Category, Stop 0: 4 | Rated operating voltage: 24 | EPLAN: Yes | Performance Level, stop 0, up to: e | Integral system diagnostics, status: Yes | Restistance to shock: 10 g / 11 ms | Rated control voltage at AC 50 Hz, maximum: 26.4 | Ripple voltage: 10 | Current, Utilisation category DC-13: 4 | Rated control voltage at DC, maximum: 28.8 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Conduction resistance, maximum: 40 | Automatic reset function: Yes | Indicated operating states: Position relay K1/K2 | Voltage type: AC | Terminal designations: EN 60947-1 | Number of LEDs: 1 | Switching capacity, minimum: 10 | CADENAS: Yes | Rated control voltage at AC 60 Hz, maximum: 26.4 | Earth connection detection: Yes | Number of normally closed (NC): 1 | TOL_VOLT_OPERAT_DC_MAX: 20 | IP Degree of protection of the installation space: IP54 | Allowed type of cable: solid single-wire | Height: 98 | Cable section: 0.2 mm², rigid0.2 mm², flexible0.25 mm², flexible with ferrule ... 2.5 mm², rigid2.5 mm², flexible2.5 mm², flexible with ferrule | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 4 A | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | PFH value, Stop 0: 2.00 x 10⁻⁸ | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | TOL_VOLT_OPERAT_AC_MIN: -15 | Current, Utilisation category AC-15: 4 | TOL_VOLT_OPERAT_AC_MAX: 10 | Removable Terminals: Yes | IP Degree of protection of the enclosure: IP40 | Pull-in delay at automatic start, maximum, typically: 20 | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 4 A | TOL_VOLT_OPERAT_DC_MIN: -15 | Diagnostic Coverage (DC) Level, Stop 0: ≥ 99 | Width: 22.5 | Note (Contact resistance): in new state | Depth: 115 | Climatic stress: EN 60068-2-78 | Safety Integrity Level (SIL), Stop 0, suitable for applications in: 3 | Tightening torque of Clips: 0.5 | Electrical power consumption: 2.2 | Drop-out delay, maximum: 35 | Stop-Category: 0 | Voltage, Utilisation category AC-15: 230 | Terminal (mechanical): Removable screw terminals

More Schmersal Products from Glorient

In addition to SRB-E-402EM, Glorient also supplies:

T4VH 336-02YR Order No: 151149582
NZSO2/30/V4A Order No: 101185237
SSG-SK1.2 Order No: 103008115
Z4VH 335-11Z-G24-M20 Order No: 151154489
NBGLC33.3/NSK Order No: 103032719
TESFA/S Order No: 101181958
TD 452-12Y-T-1276-2-RMS Order No: 101115834
BDF100-20-SWS20-G/GN-ST Order No: 103008514
SLC440COM-E-0330-14-1700 Order No: 103040460
BN 310-10Z Order No: 101133842
UAM-05LP-OC Order No: 103039889
RZSO1/1 Order No: 101205580
PS215-Z02-R200-U2 Order No: 103027027
ESS21S1/EKM183 Order No: 103050337
SVE2/151/151-3Ö-24VDC Order No: 103027411
AV25LKX11.5U-GB215 Order No: 103016463
EWS21ÖBB Order No: 101051543
EX-Z4V7H 335-02Z-3G/D Order No: 101194203
MD 441-11Y-2186 Order No: 101138562
PS215-Z02A1-R200 Order No: 103028204
CODIERUNG PROTECT 22,5 PTR Order No: 103000437
TV7H 236-20Z-2138-2/1894 Order No: 153001331
SHGV/B01/303+BOW Order No: 101198420
BN 310-RZ 0,35M Order No: 103001552
BP 8 Order No: 101054816
M 610-11-21-1A-III Order No: 101087693
AZM 170-02ZRK-ST8 24VAC/DC Order No: 101184218
SHGV/B1.1/214+BOW Order No: 103037104
TZFWS24VDC Order No: 131022605

Related Guides

Gross weight250 g
Net weight250 g
Ambient temperature-25 ... +60 °C
Ambient temperature, maximum1000731698 °C
Ambient temperature, minimum-25 °C
StandardsEN IEC 60947-5-3
CertificatescULus, CCC
Housing materialGlass-fibre reinforced thermoplastic, ventilated
EAN (European Article Number)4030661563411
Mission time20
Mechanical lifetime, minimum10,000,000
Cable section, maximum2.5 mm²
Material of the contacts, electricalAg-Ni, self-cleaning, positive drive
Cable section, minimum0.25 mm²
Number of safety contacts4
Number of auxiliary contacts2
TracepartsYes
Resistance to vibrations10...55 Hz, Amplitude 0.35 mm, ± 15 %
Storage and transport temperature-40 ... +85 °C
Storage and transport temperature, maximum+85 °C
Storage and transport temperature, minimum-40 °C
MountingSnaps onto standard DIN rail to EN 60715
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Degree of pollution2
Other ParametersSwitching capacity, maximum: 250 | Rated AC voltage for controls, 50 Hz, minimum: 20.4 | Rated AC voltage for controls, 60 Hz, minimum: 20.4 | Overvoltage category: III | Rated AC voltage for controls at DC minimum: 20.4 | Common Cause Failure (CCF), minimum: 65 | Category, Stop 0: 4 | Rated operating voltage: 24 | EPLAN: Yes | Performance Level, stop 0, up to: e | Integral system diagnostics, status: Yes | Restistance to shock: 10 g / 11 ms | Rated control voltage at AC 50 Hz, maximum: 26.4 | Ripple voltage: 10 | Current, Utilisation category DC-13: 4 | Rated control voltage at DC, maximum: 28.8 | Contact resistance, maximum: 0.1 | Frequency range: 50 | Conduction resistance, maximum: 40 | Automatic reset function: Yes | Indicated operating states: Position relay K1/K2 | Voltage type: AC | Terminal designations: EN 60947-1 | Number of LEDs: 1 | Switching capacity, minimum: 10 | CADENAS: Yes | Rated control voltage at AC 60 Hz, maximum: 26.4 | Earth connection detection: Yes | Number of normally closed (NC): 1 | TOL_VOLT_OPERAT_DC_MAX: 20 | IP Degree of protection of the installation space: IP54 | Allowed type of cable: solid single-wire | Height: 98 | Cable section: 0.2 mm², rigid0.2 mm², flexible0.25 mm², flexible with ferrule ... 2.5 mm², rigid2.5 mm², flexible2.5 mm², flexible with ferrule | ELEC_UTILISAT_CAT_DC13_SROUT_GPV: 24 VDC / 4 A | EMC rating: EMC-Directive | IP Degree of protection of clips or terminals: IP20 | PFH value, Stop 0: 2.00 x 10⁻⁸ | Voltage, Utilisation category DC-13: 24 | Wire breakage detection : Yes | TOL_VOLT_OPERAT_AC_MIN: -15 | Current, Utilisation category AC-15: 4 | TOL_VOLT_OPERAT_AC_MAX: 10 | Removable Terminals: Yes | IP Degree of protection of the enclosure: IP40 | Pull-in delay at automatic start, maximum, typically: 20 | ELEC_UTILISAT_CAT_AC15_SROUT_GPV: 230 VAC / 4 A | TOL_VOLT_OPERAT_DC_MIN: -15 | Diagnostic Coverage (DC) Level, Stop 0: ≥ 99 | Width: 22.5 | Note (Contact resistance): in new state | Depth: 115 | Climatic stress: EN 60068-2-78 | Safety Integrity Level (SIL), Stop 0, suitable for applications in: 3 | Tightening torque of Clips: 0.5 | Electrical power consumption: 2.2 | Drop-out delay, maximum: 35 | Stop-Category: 0 | Voltage, Utilisation category AC-15: 230 | Terminal (mechanical): Removable screw terminals