Welcome to Shenzhen Glorient International Trade Co., Ltd. Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

CPH7000

CPH7000

Model: CPH7000
Brand: WIKA Stock
Category: Calibration Technology
Views: 1 views

Products Introduction

WIKA CPH7000 - high-precision industrial measurement instrument.

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of WIKA CPH7000. Competitive pricing, fast quotation.

WIKA CPH7000 - high-precision industrial measurement instrument.

Product Introduction

WIKA is a global market leader in pressure and temperature measurement technology. With over 75 years of experience, WIKA instruments are trusted in process industries worldwide. Glorient is a professional supplier of genuine WIKA products with competitive pricing and fast worldwide delivery.

Applications

Manual pressure generation of -0.85 … +25 bar [12.3 ... +360 psi] Accuracy: 0.025 % FS (incl. calibration certificate) Generation/measurement of 0 ... 24 mA and voltage supply DC 24 V Data logger with high measuring rate and large memory Intrinsically safe version

Key Features

General information The model CPH7000 process calibrator is a precise, portable calibrator for the calibration and checking of analogue pressure measuring instruments, pressure transmitters and process transmitters. The CPH7000 in Ex version can also be used in hazardous areas. Furthermore, pressure switches can be checked and the switching point determined. With the CPH7000, not only can transmitters be checked, but also simulated and tested. Design The CPH7000 optionally features an integrated reference pressure sensor and also a manual pressure generation, with which pressures of -0.85 ... +25 bar [12.3 ... +360 psi] can be generated. It is possible to simultaneously power an external transmitter via the electrical module and to measure (or also simulate) its output signal. Functions The calibrator offers the possibility to set calibration routines quickly and easily, but also to run preconfigured calibration routines and automatically save the measured values. Over the WIKA-Wireless interface, the completed calibration processes can be transmitted to a PC. This data can subsequently be evaluated and archived using WIKA-CAL software. Thus a completely paperless transmitter calibration is possible with just the CPH7000. Accuracy The CPH7000 is temperature compensated and achieves an accuracy of 0.025 % of span. In order to avoid intricate calculations, the measured values can also be displayed directly in customer-specific units.

ApplicationsCalibration service companies and service industry
Measurement and control laboratories
Quality assurance
On-site calibration (safety also in hazardous areas)
Special FeaturesManual pressure generation of -0.85 … +25 bar [12.3 ... +360 psi]
Accuracy: 0.025 % FS (incl. calibration certificate)
Generation/measurement of 0 ... 24 mA and voltage supply DC 24 V
Data logger with high measuring rate and large memory
Intrinsically safe version
Description**General information**The model CPH7000 process calibrator is a precise, portable calibrator for the calibration and checking of analogue pressure measuring instruments, pressure transmitters and process transmitters. The CPH7000 in Ex version can also be used in hazardous areas. Furthermore, pressure switches can be checked and the switching point determined. With the CPH7000, not only can transmitters be checked, but also simulated and tested.
**Design**The CPH7000 optionally features an integrated reference pressure sensor and also a manual pressure generation, with which pressures of -0.85 ... +25 bar [12.3 ... +360 psi] can be generated. It is possible to simultaneously power an external transmitter via the electrical module and to measure (or also simulate) its output signal.
**Functions**The calibrator offers the possibility to set calibration routines quickly and easily, but also to run preconfigured calibration routines and automatically save the measured values. Over the WIKA-Wireless interface, the completed calibration processes can be transmitted to a PC. This data can subsequently be evaluated and archived using WIKA-CAL software. Thus a completely paperless transmitter calibration is possible with just the CPH7000.
**Accuracy**The CPH7000 is temperature compensated and achieves an accuracy of 0.025 % of span. In order to avoid intricate calculations, the measured values can also be displayed directly in customer-specific units.
[Details](https://www.wika.com/en-us/cph7000.WIKA)[Downloads](https://www.wika.com/en-us/cph7000.WIKA)[Standard articles](https://www.wika.com/en-us/cph7000.WIKA)