Glorient offers competitive supply of WIKA 113.53. Competitive pricing, fast quotation.
WIKA 113.53 - high-precision industrial measurement instrument.
WIKA is a global market leader in pressure and temperature measurement technology. With over 75 years of experience, WIKA instruments are trusted in process industries worldwide. Glorient is a professional supplier of genuine WIKA products with competitive pricing and fast worldwide delivery.
Stainless steel case Copper alloy wetted parts Liquid-filled case Compound pressure ranges to 200 PSI (16 bar) Positive pressure ranges to 5000 PSI (350 bar)
Design EN 837-1 & ASME B40.100 Nominal Size 1.5” (40 mm) Accuracy class ±2.5 % of span Scale Ranges 0/30 psi (2 bar) to 0/5,000 psi (350 bar) or other equivalent units of pressure or vacuum Working Pressure Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value Operating Temperature Ambient: -4 °F to +140 °F (-20 °C to +60 °C) Medium: +140 °F (+60 °C) Temperature error Additional error when temperature changes from reference temperature of 68 °F (20 °C) + 0.4 % of span for every 18 °F (10 °K) rising or falling Weather protection IP66 per EN 60 529 / IEC 529
| Applications | Liquid filled case for applications with high dynamic pressure pulsations or vibration Suitable for all gaseous and liquid media that will not obstruct the pressure system or attack copper alloy wetted parts |
| Special Features | Stainless steel case Copper alloy wetted parts Liquid-filled case Compound pressure ranges to 200 PSI (16 bar) Positive pressure ranges to 5000 PSI (350 bar) |
| Design | EN 837-1 & ASME B40.100 |
| Nominal Size | 1.5” (40 mm) |
| Accuracy class | ±2.5 % of span |
| Scale Ranges | 0/30 psi (2 bar) to 0/5,000 psi (350 bar) or other equivalent units of pressure or vacuum |
| Working Pressure | Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value |
| Operating Temperature | Ambient: -4 °F to +140 °F (-20 °C to +60 °C) Medium: +140 °F (+60 °C) |
| Temperature error | Additional error when temperature changes from reference temperature of 68 °F (20 °C) + 0.4 % of span for every 18 °F (10 °K) rising or falling |
| Weather protection | IP66 per EN 60 529 / IEC 529 [Details](https://www.wika.com/en-us/113_53.WIKA)[Downloads](https://www.wika.com/en-us/113_53.WIKA)[Standard articles](https://www.wika.com/en-us/113_53.WIKA) |