WIKA 732.31, 733.31, 732.51, 733.51, Pressure gauges engineered for professional Pressure Measurement use. Key features include Differential pressure measuring ranges from 0 … 16 mbar [0.23. Glorient supplies genuine WIKA parts with fast global delivery.
Glorient offers competitive supply of WIKA 732.31, 733.31, 732.51, 733.51. Competitive pricing, fast quotation.
WIKA 732.31, 733.31, 732.51, 733.51 - high-precision industrial measurement instrument.
WIKA is a global market leader in pressure and temperature measurement technology. With over 75 years of experience, WIKA instruments are trusted in process industries worldwide. Glorient is a professional supplier of genuine WIKA products with competitive pricing and fast worldwide delivery.
| Product Category | Pressure Measurement |
| Product Type | Pressure gauges |
| Summary | Process Industry Design, All Welded Construction, Diaphragm Element Series |
| Applications | For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive environments Pump monitoring and control Filter monitoring Level measurement on closed vessels |
| Key Features | Differential pressure measuring ranges from 0 … 16 mbar [0.23 psi] High working pressure (static pressure) up to 40 bar [580 psi] High overload safety up to 40 bar [580 psi] Model 73x.31: Case with safety level “S3” per EN 837 All-welded media chamber |
| Description | Design Lower mount process connections, highly corrosion-resistant all-metal construction, measuring cell protected against tampering. Location of process connection can be modified to mounting requirements. WIKA trade pattern DT - GM 86 08 176 Sizes 4” (100 mm) 6” (160 mm) Accuracy Class 1.6 Ranges 0 ... 6” WC (16 mbar) up to 0 ... 360 psi (25 bar) Scale range 0 ...6” WC (25 bar): Scale length approx. 180 degrees of angle Other equivalent differential pressure ranges or compound ranges available. Working Pressure Steady: full-scale value Fluctuating: 0.9 x full-scale value Operating Temperature Ambient:-4°F...+140°F (-20...+60°C) Medium: + 212°F (+100°C) maximum Temperature error Additioanal error when temperature changes from reference temperature of 68°F (20°C) ± 0.5% of span for every 18°F (10K°) rising or falling. Ingress protection NEMA 3 (IP 54 per EN 60529 / IEC 529) NEMA 4 (IP 66) with liquid filling Measuring chamber with process connection (wetted) 316 SS lower mount (LM), 2 x ¼“ NPT female Pressure elements (wetted) ≤ 100“ WC (250 mbar): 316 SS > 100“ WC (250 mbar): NiCr-alloy (Inconel®) Sealing bellows (wetted) 316 SS Venting of the media chambers (wetted) 316 SS for scale ranges ≤ 100“ WC (250 mbar) (optional for scale ranges > 100“ WC) Movement Stainless steel Dial Aluminium, white, black lettering Pointer Model 732.51: Adjustable pointer, aluminium, black Model 733.51: Standard pointer, aluminium, black Case Stainless steel, with pressure relief disc Window Laminated safety glass Bezel ring Bayonet ring, stainless steel Gauge Mounting Pressure ports marked ⊕ and ⊖ ⊕ high pressure ⊖ low pressure Mounting by means of: Direct mounting Mounting holes in measuring flange Front flange (optional) Mounting bracket for wall or pipe mounting (optional) |
TC10-L | TF44 | TR10-K | TR75 | TW81 | 111.10DW | 130.15 | s 212.54, 213.54 | s 232.50 4.5, 233.50 4.5 | A2G-25 | AZK02 | CPB3800 | CPP10-H | F1102 | F1224 | FLC-2770 | FLS | IFC | T16 | TC45 | 233.50SUBSEA | 332.34 | 532.53+8xx | 712.25DX | 910.12.200 | 910.18.100 | 981.27 | 990.30 | A2G-05 | APGT43.100, APGT43.160
| Product Category | Pressure Measurement |
| Product Type | Pressure gauges |
| Summary | Process Industry Design, All Welded Construction, Diaphragm Element Series |
| Applications | For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive environments Pump monitoring and control Filter monitoring Level measurement on closed vessels |
| Key Features | Differential pressure measuring ranges from 0 … 16 mbar [0.23 psi] High working pressure (static pressure) up to 40 bar [580 psi] High overload safety up to 40 bar [580 psi] Model 73x.31: Case with safety level “S3” per EN 837 All-welded media chamber |
| Description | Design Lower mount process connections, highly corrosion-resistant all-metal construction, measuring cell protected against tampering. Location of process connection can be modified to mounting requirements. WIKA trade pattern DT - GM 86 08 176 Sizes 4” (100 mm) 6” (160 mm) Accuracy Class 1.6 Ranges 0 ... 6” WC (16 mbar) up to 0 ... 360 psi (25 bar) Scale range 0 ...6” WC (25 bar): Scale length approx. 180 degrees of angle Other equivalent differential pressure ranges or compound ranges available. Working Pressure Steady: full-scale value Fluctuating: 0.9 x full-scale value Operating Temperature Ambient:-4°F...+140°F (-20...+60°C) Medium: + 212°F (+100°C) maximum Temperature error Additioanal error when temperature changes from reference temperature of 68°F (20°C) ± 0.5% of span for every 18°F (10K°) rising or falling. Ingress protection NEMA 3 (IP 54 per EN 60529 / IEC 529) NEMA 4 (IP 66) with liquid filling Measuring chamber with process connection (wetted) 316 SS lower mount (LM), 2 x ¼“ NPT female Pressure elements (wetted) ≤ 100“ WC (250 mbar): 316 SS > 100“ WC (250 mbar): NiCr-alloy (Inconel®) Sealing bellows (wetted) 316 SS Venting of the media chambers (wetted) 316 SS for scale ranges ≤ 100“ WC (250 mbar) (optional for scale ranges > 100“ WC) Movement Stainless steel Dial Aluminium, white, black lettering Pointer Model 732.51: Adjustable pointer, aluminium, black Model 733.51: Standard pointer, aluminium, black Case Stainless steel, with pressure relief disc Window Laminated safety glass Bezel ring Bayonet ring, stainless steel Gauge Mounting Pressure ports marked ⊕ and ⊖ ⊕ high pressure ⊖ low pressure Mounting by means of: Direct mounting Mounting holes in measuring flange Front flange (optional) Mounting bracket for wall or pipe mounting (optional) |