Products Introduction

WIKA 904 is a genuine pressure measurement engineered for demanding industrial applications. Manufactured to original WIKA quality standards. Specifications: Product Category: Pressure Measurement; Product Type: Electrical accessories; Summary: For...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of WIKA 904. Competitive pricing, fast quotation.

WIKA 904 - high-precision industrial measurement instrument.

Product Introduction

WIKA is a global market leader in pressure and temperature measurement technology. With over 75 years of experience, WIKA instruments are trusted in process industries worldwide. Glorient is a professional supplier of genuine WIKA products with competitive pricing and fast worldwide delivery.

Applications

  • Measuring instruments with WIKA inductive contact devices may be used in operation rooms subject to explosion hazards in danger areas of Zone 1 and Zone 2. Provided they are supplied from a suitable and certified control circuit (e.g. WIKA control device of type 904.15). Besides the Ex areas WIKA inductive contact devices are primarily used where it is crucial to obtain especially safe contact with high switching frequency. Since the contacts function in liquid filling, they can be used even under very specific operating conditions. Some typical application fields are chemistry, petrochemistry and nuclear facilities.

Technical Specifications

Product CategoryPressure Measurement
Product TypeElectrical accessories
SummaryFor use with inductive contact devices
ApplicationsMeasuring instruments with WIKA inductive contact devices may be used in operation rooms subject to explosion hazards in danger areas of Zone 1 and Zone 2. Provided they are supplied from a suitable and certified control circuit (e.g. WIKA control device of type 904.15). Besides the Ex areas WIKA inductive contact devices are primarily used where it is crucial to obtain especially safe contact with high switching frequency. Since the contacts function in liquid filling, they can be used even under very specific operating conditions. Some typical application fields are chemistry, petrochemistry and nuclear facilities.
Key Features904.28 for 1 inductive contact, output: 1 x SPDT 904.29 for 2 inductive contacts, output: 2 x SPDT 904.30 for 1 inductive contact, safety equipment (SN or S1N), output:1 x fail-safe relay output; 1 x serially switched output; 1 x passive electronic output type of protection: EEx-ia IIc electrical ratings: AC 250 V / 2 A / 500 VA (1 A for typ 904.30) on delay and drop out delay: 20 ms ambient temperature: -20.. +60 °C ingress protection IP 20 control units with DC 20.. 30 V power supply Model 904.31 - 1 relay output Model 904.32 - 2 relay output Model 904.33 - 1 fail-safe relay output
DescriptionThe WIKA inductive contact device is a contact-free device. Basically, it consists of an initiator, located on the nominal value pointer, including its fully potted electronics and mechanical construction with a movable control vane. The control vane is moved by the instrument pointer (nominal value pointer). The initiator is supplied with DC voltage. If the control vane moves into the clearance of the initiator, its internal resistance increases (= activated state / the initiator has high-resistance). The change in the current rating arising from this is the input signal for the switching amplifier of the control device.

More WIKA Products

TLS-H  |  TR22-B  |  TW31  |  1000-6I  |  111.16PM  |  212.20  |  232.30, 233.30  |  70-8xx  |  A50  |  BNA  |  CPG2500  |  ELMS1  |  F1135  |  F1848  |  FLRU-SFI  |  GCx-20  |  PU-548  |  TC10-9  |  TC59-X  |  300-6D  |  s 432.36, 433.36  |  700.06  |  910.10  |  910.15.200  |  910.32.250  |  990.23  |  990.51  |  A2G-540  |  C9-6120  |  CPT6020

Related Guides

Product CategoryPressure Measurement
Product TypeElectrical accessories
SummaryFor use with inductive contact devices
ApplicationsMeasuring instruments with WIKA inductive contact devices may be used in operation rooms subject to explosion hazards in danger areas of Zone 1 and Zone 2. Provided they are supplied from a suitable and certified control circuit (e.g. WIKA control device of type 904.15). Besides the Ex areas WIKA inductive contact devices are primarily used where it is crucial to obtain especially safe contact with high switching frequency. Since the contacts function in liquid filling, they can be used even under very specific operating conditions. Some typical application fields are chemistry, petrochemistry and nuclear facilities.
Key Features904.28 for 1 inductive contact, output: 1 x SPDT 904.29 for 2 inductive contacts, output: 2 x SPDT 904.30 for 1 inductive contact, safety equipment (SN or S1N), output:1 x fail-safe relay output; 1 x serially switched output; 1 x passive electronic output type of protection: EEx-ia IIc electrical ratings: AC 250 V / 2 A / 500 VA (1 A for typ 904.30) on delay and drop out delay: 20 ms ambient temperature: -20.. +60 °C ingress protection IP 20 control units with DC 20.. 30 V power supply Model 904.31 - 1 relay output Model 904.32 - 2 relay output Model 904.33 - 1 fail-safe relay output
DescriptionThe WIKA inductive contact device is a contact-free device. Basically, it consists of an initiator, located on the nominal value pointer, including its fully potted electronics and mechanical construction with a movable control vane. The control vane is moved by the instrument pointer (nominal value pointer). The initiator is supplied with DC voltage. If the control vane moves into the clearance of the initiator, its internal resistance increases (= activated state / the initiator has high-resistance). The change in the current rating arising from this is the input signal for the switching amplifier of the control device.