Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

FSD-4

FSD-4

Model: FSD-4
Brand: WIKA Stock
Category: Flow Measurement
Views: 9 views

Products Introduction

WIKA FSD-4, Flow switches engineered for professional Flow Measurement use. Typical applications: Control of cooling lubricant systems Monitoring of coolant circuits Control of filter units Dry run protection in pumps.

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of WIKA FSD-4. Competitive pricing, fast quotation.

WIKA FSD-4 - high-precision industrial measurement instrument.

Product Introduction

WIKA is a global market leader in pressure and temperature measurement technology. With over 75 years of experience, WIKA instruments are trusted in process industries worldwide. Glorient is a professional supplier of genuine WIKA products with competitive pricing and fast worldwide delivery.

Applications

  • Control of cooling lubricant systems Monitoring of coolant circuits Control of filter units Dry run protection in pumps

Technical Specifications

Product CategoryFlow Measurement
Product TypeFlow switches
SummaryFor liquid media
ApplicationsControl of cooling lubricant systems Monitoring of coolant circuits Control of filter units Dry run protection in pumps
Key FeaturesWear-free flow monitoring of liquid media using the calorimetric principle Flexibly configurable switching and analogue outputs for flow and temperature Easily parameterisable via 3-button operation or optionally via IO-Link 1.1 Exact adaptation to the conditions on-site
DescriptionThe model FSD-4 electronic flow switch offers full flexibility in monitoring and controlling flow based on the velocities of liquid media. The switch points of the model FSD-4 can be freely configured very easily via the 3-button operation directly on the instrument or optionally via IO-Link. The model FSD-4 can output both absolute values in various units and relative flow values and display them on the digital indicator. Exact matching to the conditions on-site The flow is determined by many factors such as the pipe diameter, the system set-up or the medium. Therefore, depending on the application, the actual flow value may differ from the calibrated value. Thanks to the teach function, the model FSD-4 can be set to the zero point and the maximum flow at the respective measuring location and thus optimally adjusted to the measuring conditions. The compression fitting on the flow switch offers additional flexibility. Depending on the pipe diameter, the immersion depth and alignment can be individually adjusted. Flexibly configurable switching outputs Depending on the configuration, the model FSD-4 has up to two switch points plus analogue output, which can be freely programmed. Since the switch determines its flow data using a calorimetric measurement principle, the second switching output can also be enabled for a temperature value, while the first outputs a switching signal using the flow value. The flow switch can thus additionally be used for simple temperaturecontrolled processes. Easy access via IO-Link version 1.1 The parameters are set either via 3-button operation on the instrument or, optionally, via IO-Link. When changing the instrument, the settings for the respective measuring location can be transferred directly to the new flow switch. This eliminates the need for any repeat parameterisation at the measuring location and reduces the necessary integration effort. With IO-Link, additional functions such as an operating hours counter or max value memory can be called up and used for condition monitoring.

More WIKA Products

GDI-063  |  GFK-10  |  GWS-10  |  IPT-20, IPT-21  |  LS-1000  |  M-10, M-11  |  OLS-5200  |  PG23HP-P  |  PGS25  |  PMT10  |  RLS-3000  |  S-11  |  TC97  |  TG58SA  |  TI.80  |  s TR10-AVG, TR15-AVG  |  TR45  |  s TT.80, TT.82  |  s TW.SW, TW20  |  s A-AI-1, A-IAI-1, DI10, DI32-1  |  612.34, 632.34, 633.34  |  910.33  |  990.50  |  CPA2501  |  CTP1500  |  DSS19F  |  DW03UN  |  F9841  |  PG23CP  |  TC10-F

Related Guides

Product CategoryFlow Measurement
Product TypeFlow switches
SummaryFor liquid media
ApplicationsControl of cooling lubricant systems Monitoring of coolant circuits Control of filter units Dry run protection in pumps
Key FeaturesWear-free flow monitoring of liquid media using the calorimetric principle Flexibly configurable switching and analogue outputs for flow and temperature Easily parameterisable via 3-button operation or optionally via IO-Link 1.1 Exact adaptation to the conditions on-site
DescriptionThe model FSD-4 electronic flow switch offers full flexibility in monitoring and controlling flow based on the velocities of liquid media. The switch points of the model FSD-4 can be freely configured very easily via the 3-button operation directly on the instrument or optionally via IO-Link. The model FSD-4 can output both absolute values in various units and relative flow values and display them on the digital indicator. Exact matching to the conditions on-site The flow is determined by many factors such as the pipe diameter, the system set-up or the medium. Therefore, depending on the application, the actual flow value may differ from the calibrated value. Thanks to the teach function, the model FSD-4 can be set to the zero point and the maximum flow at the respective measuring location and thus optimally adjusted to the measuring conditions. The compression fitting on the flow switch offers additional flexibility. Depending on the pipe diameter, the immersion depth and alignment can be individually adjusted. Flexibly configurable switching outputs Depending on the configuration, the model FSD-4 has up to two switch points plus analogue output, which can be freely programmed. Since the switch determines its flow data using a calorimetric measurement principle, the second switching output can also be enabled for a temperature value, while the first outputs a switching signal using the flow value. The flow switch can thus additionally be used for simple temperaturecontrolled processes. Easy access via IO-Link version 1.1 The parameters are set either via 3-button operation on the instrument or, optionally, via IO-Link. When changing the instrument, the settings for the respective measuring location can be transferred directly to the new flow switch. This eliminates the need for any repeat parameterisation at the measuring location and reduces the necessary integration effort. With IO-Link, additional functions such as an operating hours counter or max value memory can be called up and used for condition monitoring.