Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

FSK01

FSK01

Model: FSK01
Brand: WIKA Stock
Category: Force Measurement
Views: 11 views

Products Introduction

The FSK01 from WIKA is designed for professional Force Measurement applications. Typical applications: Measurement of electrode forces for spot welding equipment. For 10 kN, 20 kN welding tongs. Glorient supplies genuine WIKA parts with fast global delivery.

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of WIKA FSK01. Competitive pricing, fast quotation.

WIKA FSK01 - high-precision industrial measurement instrument.

Product Introduction

WIKA is a global market leader in pressure and temperature measurement technology. With over 75 years of experience, WIKA instruments are trusted in process industries worldwide. Glorient is a professional supplier of genuine WIKA products with competitive pricing and fast worldwide delivery.

Applications

  • Measurement of electrode forces for spot welding equipment

Technical Specifications

Product CategoryForce Measurement
Product TypeSpecial force transducers
SummaryFor 10 kN, 20 kN welding tongs
ApplicationsMeasurement of electrode forces for spot welding equipment
Key FeaturesMeasuring ranges 10 kN, 20 kN Relative linearity error 0.2 % F nom Low overall weight of approx. 6 kg Maximum/Minimum value memory Electrode diameter 14 … 20 mm
DescriptionThe test set is used for the monitoring of electrode forces for spot welding equipment. The set consists of a force transducer and display unit. To test the forces acting between the electrodes, the force transducer is held between the electrodes. The concave force introduction surfaces centre the force transducer. When the welding electrodes come together, the magnitude of the applied force can be read off the indicator. The force transducer is designed as a shear beam load cell. It is insensitive to lateral forces and moments. The output signal is fed to the indicator via a cable. This also supplies the force transducer with its operating voltage. Alternatively, the supply voltage can also be taken from a PLC. In this type of force transducer, proven thin-film sensor technology is integrated. The laser-welded sensor has all the advantages of conventional glued film strain gauges, without, however, being affected by their major disadvantages (temperature behaviour of the adhesive and creep). Calibration Force transducer and indicator are calibrated together as a measuring chain. A repeat calibration is recommended every 12 months. This service can be carried out quickly and reliably by WIKA. Scope of delivery Hand-held indicator, force transducer, plastic case, charger, 2 m signal cable, manufacturer's test certificate

More WIKA Products

GFU08-B, GFU08-C, GFU08-E, GFU08-W  |  HPAC  |  IS-20-VR  |  s M932.25, M933.25  |  N1101  |  OLS-C01  |  PG23HP-S  |  PGS43.100, PGS43.160  |  PSD-4  |  RLS-4000  |  S-20  |  TCA  |  TGT73  |  TI.82  |  TR10-B  |  TR50  |  TW10  |  TXA  |  TW.WI / TW25  |  614.11, 634.11  |  910.61  |  990.60  |  CPB5600DP  |  CTP6000  |  DSS19T  |  E1930  |  F9846  |  PG28  |  TC10-H  |  TF37

Related Guides

Product CategoryForce Measurement
Product TypeSpecial force transducers
SummaryFor 10 kN, 20 kN welding tongs
ApplicationsMeasurement of electrode forces for spot welding equipment
Key FeaturesMeasuring ranges 10 kN, 20 kN Relative linearity error 0.2 % F nom Low overall weight of approx. 6 kg Maximum/Minimum value memory Electrode diameter 14 … 20 mm
DescriptionThe test set is used for the monitoring of electrode forces for spot welding equipment. The set consists of a force transducer and display unit. To test the forces acting between the electrodes, the force transducer is held between the electrodes. The concave force introduction surfaces centre the force transducer. When the welding electrodes come together, the magnitude of the applied force can be read off the indicator. The force transducer is designed as a shear beam load cell. It is insensitive to lateral forces and moments. The output signal is fed to the indicator via a cable. This also supplies the force transducer with its operating voltage. Alternatively, the supply voltage can also be taken from a PLC. In this type of force transducer, proven thin-film sensor technology is integrated. The laser-welded sensor has all the advantages of conventional glued film strain gauges, without, however, being affected by their major disadvantages (temperature behaviour of the adhesive and creep). Calibration Force transducer and indicator are calibrated together as a measuring chain. A repeat calibration is recommended every 12 months. This service can be carried out quickly and reliably by WIKA. Scope of delivery Hand-held indicator, force transducer, plastic case, charger, 2 m signal cable, manufacturer's test certificate