Welcome to Glorient Official Website!
Service Hotline 18070781637
Email 18070781637@163.com

732.18, 733.18

732.18, 733.18

Model: 732.18, 733.18
Brand: WIKA Stock
Category: Pressure Measurement
Views: 9 views

Products Introduction

WIKA 732.18, 733.18 is a genuine pressure measurement engineered for demanding industrial applications. Manufactured to original WIKA quality standards. Specifications: Product Category: Pressure Measurement; Product Type: Pressure gauges; Summary:...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of WIKA 732.18, 733.18. Competitive pricing, fast quotation.

WIKA 732.18, 733.18 - high-precision industrial measurement instrument.

Product Introduction

WIKA is a global market leader in pressure and temperature measurement technology. With over 75 years of experience, WIKA instruments are trusted in process industries worldwide. Glorient is a professional supplier of genuine WIKA products with competitive pricing and fast worldwide delivery.

Applications

  • Measurement of the differential pressure or of two different pressures in refrigeration plants or compressors
  • Simultaneous measurement of steam pressure and the corresponding steam temperature
  • Suitable for the measurement of non-highly viscous or non-crystallising gases and liquid corrosive media in corrosive environments

Technical Specifications

Product CategoryPressure Measurement
Product TypePressure gauges
SummaryFor refrigeration technology, stainless steel version, NS 80 and 100
ApplicationsMeasurement of the differential pressure or of two different pressures in refrigeration plants or compressors; Simultaneous measurement of steam pressure and the corresponding steam temperature; Suitable for the measurement of non-highly viscous or non-crystallising gases and liquid corrosive media in corrosive environments
Key FeaturesWith adjustable differential pressure dial; Optional dual-scale design; Model 733.18 with liquid-filled case, the filling liquid dampens the effect of high dynamic pressure pulsations and vibrations and prevents condensation; Combined pressure and temperature scales, covering all common refrigerants in dual, triple or quadruple scale versions
DescriptionDesign: Two independent measuring systems with parallel connections; Nominal size (mm): 80 and 100; Accuracy class: 1.6; Measuring ranges: 0 ... 0.25 to 0 ... 6 MPa, -0.1 ... 0 ... +2.5 MPa, -0.1 ... 0 ... +1.2 MPa, -0.1 ... 0 ... +3 MPa, -0.1 ... 0 ... +1.5 MPa, -0.1 ... 0 ... +3.5 MPa, -0.1 ... 0 ... +1.6 MPa, -0.1 ... 0 ... +4 MPa; Other ranges available on request. For easy reading, the measured differential pressure should not be lower than 1/6 of the full scale. Please specify the following pressures when ordering: 1) maximum total pressure 2) differential pressure. Pressure limits: Static pressure: full scale value; Dynamic pressure: 0.9 x full scale value; Transient overpressure: 1.3 x full scale value. Permissible temperatures: Ambient temperature: 0 ... +60 °C; Medium temperature: max. +100 °C. Temperature influence: When the temperature of the measuring system fluctuates around the reference temperature (+20 °C), the maximum change is ±0.4 % / 10 K of the measuring span

More WIKA Products

PMT10  |  RLS-3000  |  S-11  |  TC97  |  TG58SA  |  TI.80  |  s TR10-AVG, TR15-AVG  |  TR45  |  s TT.80, TT.82  |  s TW.SW, TW20  |  s A-AI-1, A-IAI-1, DI10, DI32-1  |  612.34, 632.34, 633.34  |  910.33  |  990.50  |  CPA2501  |  CTP1500  |  DSS19F  |  DW03UN  |  F9841  |  PG23CP  |  TC10-F  |  TCN  |  TR10-D  |  TR31  |  TW40  |  101.00  |  111.25DW  |  s 212.34, 213.34  |  232.34, 233.34  |  74

Related Guides

Product CategoryPressure Measurement
Product TypePressure gauges
SummaryFor refrigeration technology, stainless steel version, NS 80 and 100
ApplicationsMeasurement of the differential pressure or of two different pressures in refrigeration plants or compressors; Simultaneous measurement of steam pressure and the corresponding steam temperature; Suitable for the measurement of non-highly viscous or non-crystallising gases and liquid corrosive media in corrosive environments
Key FeaturesWith adjustable differential pressure dial; Optional dual-scale design; Model 733.18 with liquid-filled case, the filling liquid dampens the effect of high dynamic pressure pulsations and vibrations and prevents condensation; Combined pressure and temperature scales, covering all common refrigerants in dual, triple or quadruple scale versions
DescriptionDesign: Two independent measuring systems with parallel connections; Nominal size (mm): 80 and 100; Accuracy class: 1.6; Measuring ranges: 0 ... 0.25 to 0 ... 6 MPa, -0.1 ... 0 ... +2.5 MPa, -0.1 ... 0 ... +1.2 MPa, -0.1 ... 0 ... +3 MPa, -0.1 ... 0 ... +1.5 MPa, -0.1 ... 0 ... +3.5 MPa, -0.1 ... 0 ... +1.6 MPa, -0.1 ... 0 ... +4 MPa; Other ranges available on request. For easy reading, the measured differential pressure should not be lower than 1/6 of the full scale. Please specify the following pressures when ordering: 1) maximum total pressure 2) differential pressure. Pressure limits: Static pressure: full scale value; Dynamic pressure: 0.9 x full scale value; Transient overpressure: 1.3 x full scale value. Permissible temperatures: Ambient temperature: 0 ... +60 °C; Medium temperature: max. +100 °C. Temperature influence: When the temperature of the measuring system fluctuates around the reference temperature (+20 °C), the maximum change is ±0.4 % / 10 K of the measuring span