Products Introduction

WIKA GDM-100-T is a genuine sf6 gas products engineered for demanding industrial applications. Manufactured to original WIKA quality standards. Specifications: Product Category: Sf6 Gas Products; Product Type: Gas density sensors; Summary: With Mod...

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of WIKA GDM-100-T. Competitive pricing, fast quotation.

WIKA GDM-100-T - high-precision industrial measurement instrument.

Product Introduction

WIKA is a global market leader in pressure and temperature measurement technology. With over 75 years of experience, WIKA instruments are trusted in process industries worldwide. Glorient is a professional supplier of genuine WIKA products with competitive pricing and fast worldwide delivery.

Applications

  • Medium and high-voltage equipment Gas density monitoring in closed SF 6 gas compartments Remote monitoring of the SF 6 condition Raising an alarm when defined limit values have been reached

Technical Specifications

Product CategorySf6 Gas Products
Product TypeGas density sensors
SummaryWith Modbus ® or analogue 4 ... 20 mA output signal
ApplicationsMedium and high-voltage equipment Gas density monitoring in closed SF 6 gas compartments Remote monitoring of the SF 6 condition Raising an alarm when defined limit values have been reached
Key FeaturesIdeally suited for smart grid or modernisation projects Modbus ® delivers measured values for pressure, temperature and gas density as digital signal The 4 ... 20 mA version outputs the absolute pressure at 20 °C [68 °F] or the gas density in g/l as an analogue signal for SF 6 gas Compact design with only one process connection Suitable for alternative gases
DescriptionGas density is a crucial operating parameter for high-voltage plants. If the required gas density is not present, safe operation of the plant cannot be guaranteed. The WIKA gas density measuring instruments provide reliable warnings against dangerously low gas levels, even under extreme ambient conditions. If the gas density drops as a result of a leakage, the switch contacts will switch. In addition to the traditional gas density monitor, with the model GDM-100-T high-precision sensors and evaluation electronics are incorporated. Via the on-site display, the pressure based on 20 °C [68 °F] can be read directly on the instrument. With the integrated switch contacts, simple switching tasks can be realised quickly and without complication. The integrated 4 ... 20 mA or Modbus ® sensors integrated or attached to the instrument enable remote monitoring of the plant. The measured data for pressure, temperature and gas density are transmitted using the standardised Modbus ® RTU protocol. The model GDM-100-T can also be configured for alternative gases consisting of N 2 , CF 4 , O 2 , CO 2 , 3M™, Novec™ 4710, He and Ar. The analogue version of the GDM-100-T uses the proven technology of the 4 ... 20 mA analogue signal and outputs the absolute pressure at 20 °C [68 °F] or the gas density in g/l for SF 6 gas as an analogue signal. The data storage enables trend analysis to be carried out, so that critical SF 6 gas conditions can be predicted and rectified in time. An optimisation of the maintenance strategy from time-based (TBM) to condition-based (CBM) is possible through the use of the gas density monitor. TBM =Time Based Maintenance CBM= Condition Based Maintenance

More WIKA Products

OLS-2, OSA-SC  |  PEW-1000  |  PGS23.100, PGS23.160, PGS26.100, PGS26.160  |  PMT01  |  RLS-2000  |  S-10-3A  |  TC96-R  |  TG54  |  s TI.901, TI.701  |  TR10-4  |  TR41  |  TT.52  |  s TW.SC, TW30  |  WU-20, WU-25, WU-26  |  611.13  |  910.21  |  990.49  |  BMD  |  CTM9350-165  |  DSS18T  |  DTT  |  F7802  |  PG21PB  |  TC10-D  |  TCL10-4  |  TR10-A  |  TR25  |  TW35  |  100.10, 100.12  |  111.25CT

Related Guides

Product CategorySf6 Gas Products
Product TypeGas density sensors
SummaryWith Modbus ® or analogue 4 ... 20 mA output signal
ApplicationsMedium and high-voltage equipment Gas density monitoring in closed SF 6 gas compartments Remote monitoring of the SF 6 condition Raising an alarm when defined limit values have been reached
Key FeaturesIdeally suited for smart grid or modernisation projects Modbus ® delivers measured values for pressure, temperature and gas density as digital signal The 4 ... 20 mA version outputs the absolute pressure at 20 °C [68 °F] or the gas density in g/l as an analogue signal for SF 6 gas Compact design with only one process connection Suitable for alternative gases
DescriptionGas density is a crucial operating parameter for high-voltage plants. If the required gas density is not present, safe operation of the plant cannot be guaranteed. The WIKA gas density measuring instruments provide reliable warnings against dangerously low gas levels, even under extreme ambient conditions. If the gas density drops as a result of a leakage, the switch contacts will switch. In addition to the traditional gas density monitor, with the model GDM-100-T high-precision sensors and evaluation electronics are incorporated. Via the on-site display, the pressure based on 20 °C [68 °F] can be read directly on the instrument. With the integrated switch contacts, simple switching tasks can be realised quickly and without complication. The integrated 4 ... 20 mA or Modbus ® sensors integrated or attached to the instrument enable remote monitoring of the plant. The measured data for pressure, temperature and gas density are transmitted using the standardised Modbus ® RTU protocol. The model GDM-100-T can also be configured for alternative gases consisting of N 2 , CF 4 , O 2 , CO 2 , 3M™, Novec™ 4710, He and Ar. The analogue version of the GDM-100-T uses the proven technology of the 4 ... 20 mA analogue signal and outputs the absolute pressure at 20 °C [68 °F] or the gas density in g/l for SF 6 gas as an analogue signal. The data storage enables trend analysis to be carried out, so that critical SF 6 gas conditions can be predicted and rectified in time. An optimisation of the maintenance strategy from time-based (TBM) to condition-based (CBM) is possible through the use of the gas density monitor. TBM =Time Based Maintenance CBM= Condition Based Maintenance