Products Introduction

The TR10-F from WIKA is designed for professional Temperature Measurement applications. Typical applications: Machine, plant and vessel construction Energy and power plant technology Chemical and petrochemical industries Food and beverage.

  • ProductsDetails
  • Technical Specifications
  • Domestic Alternative

Glorient offers competitive supply of WIKA TR10-F. Competitive pricing, fast quotation.

WIKA TR10-F - high-precision industrial measurement instrument.

Product Introduction

WIKA is a global market leader in pressure and temperature measurement technology. With over 75 years of experience, WIKA instruments are trusted in process industries worldwide. Glorient is a professional supplier of genuine WIKA products with competitive pricing and fast worldwide delivery.

Applications

  • Machine, plant and vessel construction Energy and power plant technology Chemical and petrochemical industries Food and beverage industry Sanitisation and HVAC technology

Technical Specifications

Product CategoryTemperature Measurement
Product TypeResistance thermometers
SummaryWith assembled thermowell
ApplicationsMachine, plant and vessel construction Energy and power plant technology Chemical and petrochemical industries Food and beverage industry Sanitisation and HVAC technology
Key FeaturesApplication range: -196 ... +600 °C [-320 ... +1,112 °F] With integrated thermowell Spring-loaded measuring insert (replaceable) Various approval types available for hazardous areas (see data sheet, page 2)
DescriptionThis series of thermometers is suitable for use in tanks and pipes. It can be supplied with standard flanges to DIN EN or ASME. The temperature sensor is suitable for gaseous and liquid media under medium mechanical loads. The thermowell is of fully welded design and is screwed to the terminal head. The stainless steel thermowell is suitable for use under standard chemical conditions. Coated thermowells are recommended for chemically corrosive conditions, and thermowells with a wear-resistant coating for abrasive media. Replacing the measuring insert does not require the entire sensor to be removed from the plant. The measuring insert can be inspected, tested or, if necessary, repaired while the plant is in operation. Measuring inserts of standard length have short delivery times, which is advantageous for the customer when purchasing and stocking spare parts. Insertion length, flange size, thermowell design, terminal head and sensor can all be selected according to the respective application. Various explosion-protection certificates can also be optionally selected for the TR10-F. In addition, a WIKA analogue or digital transmitter can be optionally integrated into the terminal head of the TR10-F.

More WIKA Products

TR15-2  |  TRU  |  TW30  |  VentGuard  |  112.28, 113.28, 132.28, 133.28  |  732.18, 733.18  |  981.51  |  A2G-60  |  CPC7000  |  CTR9000  |  DSS26M  |  EZE53  |  FRT  |  PSM-700  |  TC12-B, TC12-M  |  TF-LCD  |  TR11-A  |  TR95  |  UTD-10  |  111.10SP  |  s 132.53, 133.53  |  213.53  |  s 233.53, 232.53  |  A2G-61  |  B6494  |  CPB5000  |  CS4R  |  F1106  |  F1227  |  FLM-CA

Related Guides

Product CategoryTemperature Measurement
Product TypeResistance thermometers
SummaryWith assembled thermowell
ApplicationsMachine, plant and vessel construction Energy and power plant technology Chemical and petrochemical industries Food and beverage industry Sanitisation and HVAC technology
Key FeaturesApplication range: -196 ... +600 °C [-320 ... +1,112 °F] With integrated thermowell Spring-loaded measuring insert (replaceable) Various approval types available for hazardous areas (see data sheet, page 2)
DescriptionThis series of thermometers is suitable for use in tanks and pipes. It can be supplied with standard flanges to DIN EN or ASME. The temperature sensor is suitable for gaseous and liquid media under medium mechanical loads. The thermowell is of fully welded design and is screwed to the terminal head. The stainless steel thermowell is suitable for use under standard chemical conditions. Coated thermowells are recommended for chemically corrosive conditions, and thermowells with a wear-resistant coating for abrasive media. Replacing the measuring insert does not require the entire sensor to be removed from the plant. The measuring insert can be inspected, tested or, if necessary, repaired while the plant is in operation. Measuring inserts of standard length have short delivery times, which is advantageous for the customer when purchasing and stocking spare parts. Insertion length, flange size, thermowell design, terminal head and sensor can all be selected according to the respective application. Various explosion-protection certificates can also be optionally selected for the TR10-F. In addition, a WIKA analogue or digital transmitter can be optionally integrated into the terminal head of the TR10-F.